Michael C Tanner1, Christian Fischer2, Gerhard Schmidmaier2, Patrick Haubruck2.
Abstract
BACKGROUND: Implant-associated infections (IAI) remain a challenging complication in osteosynthesis. There is no consensus or clear evidence whether titanium offers a relevant clinical benefit over stainless steel.Entities:
Keywords: Implant related infection; Infection; Prevention of infection; Stainless steel implants; Titanium implants; Trauma surgery
Mesh:
Substances:
Year: 2021 PMID: 33586124 PMCID: PMC8476472 DOI: 10.1007/s15010-021-01583-z
Source DB: PubMed Journal: Infection ISSN: 0300-8126 Impact factor: 3.553
Summary of the eligibility criteria
| Inclusion criteria | Exclusion criteria |
|---|---|
| English language | Duplicate studies |
| German language | Studies investigating in only infectious behavior of titanium or stainless steel implants |
| Clinical studies | Studies investigating in implants used for elective spinal and orthopaedic surgery |
| Titanium versus stainless steel implants in fracture treatment comparative studies | Studies investigating in implants used for endoprosthesis |
| Susceptibility of implant material to infections clearly discussed | Pathological fractures |
| Studies investigating in implants used for trauma management in facial fractures |
Search strategy in the Cochrane library
| Terms | Results |
|---|---|
| MeSH descriptor: [Infection] explode all trees | 20,325 |
| MeSH descriptor: [Titanium] explode all trees | 748 |
| MeSH descriptor: [Stainless Steel] explode all trees | 265 |
| MeSH descriptor: [Postoperative Complications] explode all trees | 33,257 |
| MeSH descriptor: [Inflammation] explode all trees | 7505 |
| #4 and #2 and #3 | 6 |
| (#1 or #5) and #2 and #3 | 2 |
| #6 OR #7*1995-current | 6 |
Search strategy in the Medline database
| Terms | Results |
|---|---|
| 1 Stainless Steel/ | 6775 |
| 2 "stainless steel".ti,ab,af | 16,166 |
| 3 1 OR 2 | 16,166 |
| 4 titanium.ti,ab,af | 48,065 |
| 5 Titanium/ | 31,363 |
| 6 4 OR 5 | 48,065 |
| 7 3 AND 6 | 2325 |
| 8 Infection/ | 35,800 |
| 9 "infection".ti,ab,af | 1,085,492 |
| 10 infection/ OR postoperative complication/ OR bacterial infection/ OR implant associated infection/ OR inflammation/ | 529,409 |
| 11 8 or 9 or 10 | 1,518,218 |
| 12 7 and 11 | 167 |
| 13 limit 12 to yr = "1995 -Current" | 146 |
Search strategy in the Web of Science® database
| Terms | Results |
|---|---|
| 1 TI = "stainless steel*" | 20,320 |
| Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | |
| 2 TS = "stainless steel*" | 64,642 |
| Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | |
3 #1 OR #2 Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 64,642 |
4 TI = "titanium*" Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 43,030 |
5 TS = "titanium*" Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 150,133 |
6 #4 or #5 Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 150,133 |
7 #3 and #6 Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 5864 |
8 TI = (infection* or "postoperative complication*" or "bacterial infection*" or "implant associated infection*" or inflammation*) Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 331,482 |
9 TS = (infection* or "postoperative complication*" or "bacterial infection*" or "implant associated infection*" or inflammation*) Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 1,370,554 |
10 TI = infection* Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 260,052 |
11 TS = infection* Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 1,016,147 |
12 #8 OR #9 OR #10 OR #11 Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 1,370,554 |
13 #7 and #12 Indexes = SCI-EXPANDED, SSCI Timespan = 1995–2017 | 232 |
Fig. 1Flowchart of the record identification and selection process. Based on the PRISMA guidelines
Display of the summary of results
| Reference | Year of publication | Type of study | Title | Influence on implant related properties on the susceptibility to infection |
|---|---|---|---|---|
| Studies | ||||
| Mohamed et al | [ | Systematic review | Clinical outcomes and complications of titanium versus stainless steel elastic nail in management of paediatric femoral fractures—a systematic review | No statistical difference |
| Pieske et al | [ | RCT | Titanium Alloy Pins Versus Stainless Steel Pins in External Fixation at the Wrist: A Randomized Prospective Study | No statistical difference |
| Rozental et al | [ | Retrospective clinical trial | Functional Outcome and Complications Following Two Types of Dorsal Plating for Unstable Fractures of the Distal Part of the Radius | No statistical difference |
| Voggenreiter et al | [ | Retrospective clinical trial | Immuno-inflammatory tissue reaction to stainless-steel and titanium platesusedforinternalfixationoflongbones | No statistical difference |
| Arens et al | [ | RCT | Infection after open reduction and internal fixation with dynamic compression plates—Clinical and experimental data | No statistical difference |