OBJECTIVE: This study evaluated the efficacy of a novel treatment method utilizing high-intensity focused electromagnetic field (HIFEM) in reducing fat and strengthening the muscles in the abdominal and gluteal areas. METHODS: A total of 14 patients, aged 23 to 49 years (mean: 33.2 years) received four treatments on the abdomen and/or buttocks, each lasting for 30 minutes. Ultrasound imaging was performed at baseline, immediately post-treatment, and eight weeks after the last treatment to examine the changes in thickness of the rectus abdominis and subcutaneous fat. Additionally, waist circumference, digital photographs, and patient satisfaction were collected at the same time points. The improvement in digital images was evaluated by practitioners and the patients themselves. RESULTS: Two months after the treatments, ultrasound measurements showed, on average, a 15.7-percent reduction of subcutaneous adipose tissue and an average increase in the thickness of the rectus abdominis muscle by 26.1 percent. The abdominal circumference of the treated patients showed an average decrease of 2.84 centimeters. Immediately following the final session, the patient's satisfaction was 87.5 percent; eight weeks later, it was 100 percent. During the patient evaluation of photographs, 25 percent of the patients rated their appearance as improved, 66.7 percent as significantly improved, and 8.3 percent as greatly improved. Using the Global Aesthetic Improvement Scale, the medical practitioners rated the patients as 100-percent improved. No relevant side effects of the treatment were documented. CONCLUSION: The data collected on the HIFEM procedure evaluated here are in line with the results from clinical studies and applications of this treatment in the United States. These results support the efficacy and tolerability of the HIFEM procedure. The treatment achieved high doctor and patient satisfaction.
OBJECTIVE: This study evaluated the efficacy of a novel treatment method utilizing high-intensity focused electromagnetic field (HIFEM) in reducing fat and strengthening the muscles in the abdominal and gluteal areas. METHODS: A total of 14 patients, aged 23 to 49 years (mean: 33.2 years) received four treatments on the abdomen and/or buttocks, each lasting for 30 minutes. Ultrasound imaging was performed at baseline, immediately post-treatment, and eight weeks after the last treatment to examine the changes in thickness of the rectus abdominis and subcutaneous fat. Additionally, waist circumference, digital photographs, and patient satisfaction were collected at the same time points. The improvement in digital images was evaluated by practitioners and the patients themselves. RESULTS: Two months after the treatments, ultrasound measurements showed, on average, a 15.7-percent reduction of subcutaneous adipose tissue and an average increase in the thickness of the rectus abdominis muscle by 26.1 percent. The abdominal circumference of the treated patients showed an average decrease of 2.84 centimeters. Immediately following the final session, the patient's satisfaction was 87.5 percent; eight weeks later, it was 100 percent. During the patient evaluation of photographs, 25 percent of the patients rated their appearance as improved, 66.7 percent as significantly improved, and 8.3 percent as greatly improved. Using the Global Aesthetic Improvement Scale, the medical practitioners rated the patients as 100-percent improved. No relevant side effects of the treatment were documented. CONCLUSION: The data collected on the HIFEM procedure evaluated here are in line with the results from clinical studies and applications of this treatment in the United States. These results support the efficacy and tolerability of the HIFEM procedure. The treatment achieved high doctor and patient satisfaction.
Authors: Ethne L Nussbaum; Pamela Houghton; Joseph Anthony; Sandy Rennie; Barbara L Shay; Alison M Hoens Journal: Physiother Can Date: 2017 Impact factor: 1.037
Authors: G A Ferraro; F De Francesco; C Cataldo; F Rossano; G Nicoletti; F D'Andrea Journal: Aesthetic Plast Surg Date: 2011-11-01 Impact factor: 2.326
Authors: Lilit Garibyan; William H Sipprell; H Ray Jalian; Fernanda H Sakamoto; Mathew Avram; R Rox Anderson Journal: Lasers Surg Med Date: 2013-12-03 Impact factor: 4.025
Authors: Steven Paul Nisticò; Paolo Bonan; Federica Coli; Alice Verdelli; Irene Fusco; Francesco Gratteri; Claudia Sicilia; Carmen Cantisani; Giovanni Pellacani; Luigi Bennardo; Giovanni Cannarozzo Journal: Bioengineering (Basel) Date: 2022-04-21