Literature DB >> 33571771

Air filtration as a tool for the reduction of viral aerosols.

Nicole Zacharias1, Alexandra Haag2, Regina Brang-Lamprecht2, Jürgen Gebel2, Sarah M Essert2, Thomas Kistemann2, Martin Exner2, Nico T Mutters2, Steffen Engelhart2.   

Abstract

For testing the effectiveness of air purification devices in regard to the reduction of virus-containing aerosols, a test method involving test viruses has been lacking until now. The use of bacteriophages (phiX174 phages) is a method to test the efficiency of air purification devices under experimental conditions. Using air purifiers with a HEPA filter H14, a 4.6-6.1 Log reduction of test viruses can be achieved if bacteriophages are directly aerosolised into the air purifier, which corresponds to a reduction of 99.9974-99.9999%. Due to the complexity and individuality of air flow, an experimental approach was used in which all outside influences were minimised. The experimental setup was practical and chosen to project a scenario of direct transmission by an emitting source to a recipient. The experiments were performed with and without the air purifier at a distance of 0.75 m and 1.5 m each. Using the air purifier at a setting of 1000 m3/h, the concentration of the phiX174 phages in the air could be reduced by 2.86 Log (mean value). Nevertheless, the experiments without the air purifier showed a similar reduction rate of 2.61 Log (mean value) after 35 min. The concentration of phiX174 phages in the air could be additionally reduced up to 1 log step (maximum value) by the use of the air purifier in comparison to the experiments without. Distance was shown to be an important factor for risk reduction.
Copyright © 2021 Elsevier B.V. All rights reserved.

Keywords:  Air purification; Bacteriophages; COVID-19; Transmission; phiX174

Mesh:

Substances:

Year:  2021        PMID: 33571771     DOI: 10.1016/j.scitotenv.2021.144956

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  5 in total

1.  A review of facilities management interventions to mitigate respiratory infections in existing buildings.

Authors:  Yan Zhang; Felix Kin Peng Hui; Colin Duffield; Ali Mohammed Saeed
Journal:  Build Environ       Date:  2022-06-28       Impact factor: 7.093

2.  Graphene-Based Technologies for Tackling COVID-19 and Future Pandemics.

Authors:  Shaila Afroj; Liam Britnell; Tahmid Hasan; Daria V Andreeva; Kostya S Novoselov; Nazmul Karim
Journal:  Adv Funct Mater       Date:  2021-09-16       Impact factor: 19.924

Review 3.  [Ventilation concepts in schools for the prevention of transmission of highly infectious viruses (SARS-CoV-2) by aerosols in indoor air].

Authors:  Wolfram Birmili; Hans-Christoph Selinka; Heinz-Jörn Moriske; Anja Daniels; Wolfgang Straff
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2021-11-05       Impact factor: 1.513

4.  Experimental testing of air filter efficiency against the SARS-CoV-2 virus: The role of droplet and airborne transmission.

Authors:  Cesare Saccani; Alessandro Guzzini; Caterina Vocale; Davide Gori; Marco Pellegrini; Maria Pia Fantini; Alessandra Primavera
Journal:  Build Environ       Date:  2021-12-27       Impact factor: 7.093

5.  Reducing the Effectiveness of Ward Particulate Matter, Bacteria and Influenza Virus by Combining Two Complementary Air Purifiers.

Authors:  Bingliang Zhou; Tiantian Liu; Siqi Yi; Yuanyuan Huang; Yubing Guo; Si Huang; Chengxing Zhou; Rong Zhou; Hong Cao
Journal:  Int J Environ Res Public Health       Date:  2022-08-22       Impact factor: 4.614

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.