Literature DB >> 33562672

The Influence of Skin Thickness on Flash Glucose Monitoring System Accuracy in Dogs with Diabetes Mellitus.

Francesca Del Baldo1, Alessia Diana1, Claudia Canton1, Nikolina Linta1, Roberto Chiocchetti1, Federico Fracassi1.   

Abstract

A flash glucose monitoring system (FGMS) has been validated for use in diabetic dogs. However, it is unknown whether skin thickness affects FGMS measurements. The aim of this study was to evaluate whether FGMS accuracy is affected by skin thickness. Fourteen client-owned diabetic dogs on insulin treatment were prospectively enrolled in the study. The dogs were divided into two groups according to their ultrasound-measured skin thickness: dogs with skin thickness < 5 mm (Group 1) and dogs with skin thickness > 5 mm (Group 2). On days 1, 7 and 14, glucose curves were obtained simultaneously using the FGMS and a validated portable blood glucose meter. Paired measurements were used to calculate the mean bias and to determine accuracy according to ISO 15197:2013 criteria. The mean bias was significantly inversely correlated (p = 0.02; r = -0.6) with the mean skin thickness. Clinical accuracy was observed only in Group 2, with 99% of the results in zone A + B of the Parkes consensus error grid analysis. In conclusion, skin thickness seems to affect FGMS measurements, and the device is accurate in dogs with thicker skin (>5 mm); in dogs with thin skin (<5 mm), the clinical accuracy is low, and the results should be interpreted with caution.

Entities:  

Keywords:  canine diabetes mellitus; continuous glucose monitoring system; flash glucose monitoring system; skin thickness; ultrasound

Year:  2021        PMID: 33562672      PMCID: PMC7914766          DOI: 10.3390/ani11020408

Source DB:  PubMed          Journal:  Animals (Basel)        ISSN: 2076-2615            Impact factor:   2.752


  47 in total

1.  Skin imaging with high frequency ultrasound - preliminary results.

Authors:  E Szymańska; A Nowicki; K Mlosek; J Litniewski; M Lewandowski; W Secomski; R Tymkiewicz
Journal:  Eur J Ultrasound       Date:  2000-09

2.  A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose.

Authors:  J L Parkes; S L Slatin; S Pardo; B H Ginsberg
Journal:  Diabetes Care       Date:  2000-08       Impact factor: 19.112

3.  Ultrasonographic assessment of skin structure according to age.

Authors:  Diana Crisan; Monica Lupsor; Andreea Boca; Maria Crisan; Radu Badea
Journal:  Indian J Dermatol Venereol Leprol       Date:  2012 Jul-Aug       Impact factor: 2.545

4.  Use of high-frequency ultrasonography for evaluation of skin thickness in relation to hydration status and fluid distribution at various cutaneous sites in dogs.

Authors:  Alessia Diana; Carlo Guglielmini; Federico Fracassi; Marco Pietra; Erika Balletti; Mario Cipone
Journal:  Am J Vet Res       Date:  2008-09       Impact factor: 1.156

5.  Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology.

Authors:  Udo Hoss; Erwin Satrya Budiman
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

6.  Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensor.

Authors:  Anne Herman; Olivier Aerts; Marie Baeck; Magnus Bruze; Christophe De Block; An Goossens; Nils Hamnerius; Sara Huygens; Dominique Maiter; Dominique Tennstedt; Bernard Vandeleene; Martin Mowitz
Journal:  Contact Dermatitis       Date:  2017-08-14       Impact factor: 6.600

7.  Blood flow through human adipose tissue determined with radioactive xenon.

Authors:  O A Larsen; N A Lassen; F Quaade
Journal:  Acta Physiol Scand       Date:  1966-03

8.  Evaluation of sensor sites for continuous glucose monitoring in cats with diabetes mellitus.

Authors:  Michaela Hafner; Thomas A Lutz; Claudia E Reusch; Eric Zini
Journal:  J Feline Med Surg       Date:  2012-10-12       Impact factor: 2.015

9.  A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes.

Authors:  Arndís F Ólafsdóttir; Stig Attvall; Ulrika Sandgren; Sofia Dahlqvist; Aldina Pivodic; Stanko Skrtic; Elvar Theodorsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2017-03-06       Impact factor: 6.118

10.  Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis.

Authors:  D D Silva; G R M Cecci; G Biz; F N Chiaro; M S Zanutto
Journal:  Domest Anim Endocrinol       Date:  2020-07-18       Impact factor: 2.290

View more
  1 in total

1.  Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.

Authors:  Marieke Knies; Erik Teske; Hans Kooistra
Journal:  J Feline Med Surg       Date:  2022-06-28       Impact factor: 1.971

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.