BACKGROUND: Facet osteosynthesis can be performed to treat facet syndrome (FS) and reduce spinal instability following laminectomy in patients with lumbar spinal stenosis (LSS). The present study evaluated clinical and radiological outcomes following facet osteosynthesis with the FFX device. METHODS: Patients with FS or LSS were prospectively enrolled in a single-arm, multicenter study. The device was placed at affected levels with or without concomitant posterior lumbar interbody fusion (PLIF) procedures. The visual analog scale (VAS) for back and leg pain and Oswestry Disability Index (ODI) were evaluated preoperatively and postoperatively. Computed tomography scans to assess fusion and migration were performed 1 year following surgery. RESULTS: Fifty-three patients (26 men/27 women) with a mean age of 65.0 ± 9.6 years (range: 37-83 years) were enrolled. A total of 205 FFX devices were implanted with 15 patients undergoing concurrent PLIF procedures. There were no intraoperative or postoperative surgical complication reported, and no patient required revision surgery. Mean VAS leg and back pain scores significantly improved from 5.57 to 2.09 (P < .001) and 5.74 to 3.13 (P < .001), respectively, between the preoperative and 1 year follow-up assessments. Mean ODI scores also significantly improved from 44.7% to 24.0% (P < .001) during the same time period. Facet fusion occurred with 86.3% of device placements after 12 months. There was 1 (0.5%) asymptomatic device migration. Eight devices (3.9%) were considered misplaced. CONCLUSIONS: The use of the FFX device is associated with a significant reduction in both pain and disability following surgery with a high facet joint fusion rate. LEVEL OF EVIDENCE: 4. CLINICAL RELEVANCE: This is the first study reporting clinical experience using the FFX device to facilitate facet osteosynthesis. The ability of the device to relieve pain, reduce disability, and enhance lumbar facet fusion with a low rate of device misplacement and migration was demonstrated. This manuscript is generously published free of charge by ISASS, the International Society for the Advancement of Spine Surgery.
BACKGROUND: Facet osteosynthesis can be performed to treat facet syndrome (FS) and reduce spinal instability following laminectomy in patients with lumbar spinal stenosis (LSS). The present study evaluated clinical and radiological outcomes following facet osteosynthesis with the FFX device. METHODS:Patients with FS or LSS were prospectively enrolled in a single-arm, multicenter study. The device was placed at affected levels with or without concomitant posterior lumbar interbody fusion (PLIF) procedures. The visual analog scale (VAS) for back and leg pain and Oswestry Disability Index (ODI) were evaluated preoperatively and postoperatively. Computed tomography scans to assess fusion and migration were performed 1 year following surgery. RESULTS: Fifty-three patients (26 men/27 women) with a mean age of 65.0 ± 9.6 years (range: 37-83 years) were enrolled. A total of 205 FFX devices were implanted with 15 patients undergoing concurrent PLIF procedures. There were no intraoperative or postoperative surgical complication reported, and no patient required revision surgery. Mean VAS leg and back pain scores significantly improved from 5.57 to 2.09 (P < .001) and 5.74 to 3.13 (P < .001), respectively, between the preoperative and 1 year follow-up assessments. Mean ODI scores also significantly improved from 44.7% to 24.0% (P < .001) during the same time period. Facet fusion occurred with 86.3% of device placements after 12 months. There was 1 (0.5%) asymptomatic device migration. Eight devices (3.9%) were considered misplaced. CONCLUSIONS: The use of the FFX device is associated with a significant reduction in both pain and disability following surgery with a high facet joint fusion rate. LEVEL OF EVIDENCE: 4. CLINICAL RELEVANCE: This is the first study reporting clinical experience using the FFX device to facilitate facet osteosynthesis. The ability of the device to relieve pain, reduce disability, and enhance lumbar facet fusion with a low rate of device misplacement and migration was demonstrated. This manuscript is generously published free of charge by ISASS, the International Society for the Advancement of Spine Surgery.
Authors: Paul Park; Hugh J Garton; Vishal C Gala; Julian T Hoff; John E McGillicuddy Journal: Spine (Phila Pa 1976) Date: 2004-09-01 Impact factor: 3.468
Authors: J S Fischgrund; M Mackay; H N Herkowitz; R Brower; D M Montgomery; L T Kurz Journal: Spine (Phila Pa 1976) Date: 1997-12-15 Impact factor: 3.468
Authors: Laxmaiah Manchikanti; Salahadin Abdi; Sairam Atluri; Ramsin M Benyamin; Mark V Boswell; Ricardo M Buenaventura; David A Bryce; Patricia A Burks; David L Caraway; Aaron K Calodney; Kimberly A Cash; Paul J Christo; Steven P Cohen; James Colson; Ann Conn; Harold Cordner; Sareta Coubarous; Sukdeb Datta; Timothy R Deer; Sudhir Diwan; Frank J E Falco; Bert Fellows; Stephanie Geffert; Jay S Grider; Sanjeeva Gupta; Haroon Hameed; Mariam Hameed; Hans Hansen; Standiford Helm; Jeffrey W Janata; Rafael Justiz; Alan D Kaye; Marion Lee; Kavita N Manchikanti; Carla D McManus; Obi Onyewu; Allan T Parr; Vikram B Patel; Gabor B Racz; Nalini Sehgal; Manohar Lal Sharma; Thomas T Simopoulos; Vijay Singh; Howard S Smith; Lee T Snook; John R Swicegood; Ricardo Vallejo; Stephen P Ward; Bradley W Wargo; Jie Zhu; Joshua A Hirsch Journal: Pain Physician Date: 2013-04 Impact factor: 4.965