Quantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals.

Hao Li1, Yangyang Qu2, Patrick Metze2, Florian Sommerfeld1, Steffen Just2, Alireza Abaei1, Volker Rasche1,2.   

Abstract

Myocardial strain is a well-validated parameter for evaluating myocardial contraction. Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a novel method for the quantitative measurements of myocardial strain from routine cine acquisitions. In this study, we investigated the influence of temporal resolution on tracking accuracy of CMR-FT and the intraobserver, interobserver, and interstudy reproducibilities for biventricular strain analysis in mice from self-gated CMR at 11.7 T. 12 constitutive nexilin knockout (Nexn-KO) mice, heterozygous (Het, N = 6) and wild-type (WT, N = 6), were measured with a well-established self-gating sequence twice within two weeks. CMR-FT measures of biventricular global and segmental strain parameters were derived. Interstudy, intraobserver, and interobserver reproducibilities were investigated. For the assessment of the impact of the temporal resolution for the outcome in CMR-FT, highly oversampled semi-4 chamber and midventricular short-axis data were acquired and reconstructed with 10 to 80 phases per cardiac cycle. A generally reduced biventricular myocardial strain was observed in Nexn-KO Het mice. Excellent intraobserver and interobserver reproducibility was achieved in all global strains (ICC range from 0.76 to 0.99), where global right ventricle circumferential strain (RCSSAX) showed an only good interobserver reproducibility (ICC 0.65, 0.11-0.89). For interstudy reproducibility, left ventricle longitudinal strain (LLSLAX) was the most reproducible measure of strain (ICC 0.90, 0.71-0.97). The left ventricle radial strain (LRSSAX) (ICC 0.50, 0.10-0.83) showed fair reproducibility and RCSSAX (ICC 0.36, 0.14-0.74) showed only poor reproducibility. In general, compared with global strains, the segmental strains showed relatively lower reproducibility. A minimal temporal resolution of 20 phases per cardiac cycle appeared sufficient for CMR-FT strain analysis. The analysis of myocardial strain from high-resolution self-gated cine images by CMR-FT provides a highly reproducible method for assessing myocardial contraction in small rodent animals. Especially, global LV longitudinal and circumferential strain revealed excellent reproducibility of intra- and interobserver and interstudy measurements.
Copyright © 2021 Hao Li et al.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33553431      PMCID: PMC7847329          DOI: 10.1155/2021/8492705

Source DB:  PubMed          Journal:  Biomed Res Int            Impact factor:   3.411


  45 in total

1.  MR imaging of motion with spatial modulation of magnetization.

Authors:  L Axel; L Dougherty
Journal:  Radiology       Date:  1989-06       Impact factor: 11.105

Review 2.  New approaches in small animal echocardiography: imaging the sounds of silence.

Authors:  Rashmi Ram; Deanne M Mickelsen; Catherine Theodoropoulos; Burns C Blaxall
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-08-26       Impact factor: 4.733

3.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.

Authors:  E A Zerhouni; D M Parish; W J Rogers; A Yang; E P Shapiro
Journal:  Radiology       Date:  1988-10       Impact factor: 11.105

4.  Age- and gender-related normal references of right ventricular strain values by tissue tracking cardiac magnetic resonance: results from a Chinese population.

Authors:  Ting Liu; Congcong Wang; Shu Li; Yu Zhao; Peiling Li
Journal:  Quant Imaging Med Surg       Date:  2019-08

5.  Myocardial strain measurement with feature-tracking cardiovascular magnetic resonance: normal values.

Authors:  Robin J Taylor; William E Moody; Fraz Umar; Nicola C Edwards; Tiffany J Taylor; Berthold Stegemann; John N Townend; Kan N Hor; Richard P Steeds; Wojciech Mazur; Francisco Leyva
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-02-23       Impact factor: 6.875

6.  The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength.

Authors:  Andreas Schuster; Geraint Morton; Shazia T Hussain; Roy Jogiya; Shelby Kutty; Kaleab N Asrress; Marcus R Makowski; Boris Bigalke; Divaka Perera; Philipp Beerbaum; Eike Nagel
Journal:  Eur J Radiol       Date:  2012-12-12       Impact factor: 3.528

7.  Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of Fallot and healthy controls.

Authors:  Aleksander Kempny; Rodrigo Fernández-Jiménez; Stefan Orwat; Pia Schuler; Alexander C Bunck; David Maintz; Helmut Baumgartner; Gerhard-Paul Diller
Journal:  J Cardiovasc Magn Reson       Date:  2012-05-31       Impact factor: 5.364

8.  Right ventricular strain assessment by cardiovascular magnetic resonance myocardial feature tracking allows optimized risk stratification in Takotsubo syndrome.

Authors:  Thomas Stiermaier; Torben Lange; Amedeo Chiribiri; Christian Möller; Tobias Graf; Uwe Raaz; Adriana Villa; Johannes T Kowallick; Joachim Lotz; Gerd Hasenfuß; Holger Thiele; Andreas Schuster; Ingo Eitel
Journal:  PLoS One       Date:  2018-08-29       Impact factor: 3.240

9.  Normal values for myocardial deformation within the right heart measured by feature-tracking cardiovascular magnetic resonance imaging.

Authors:  Boyang Liu; Ahmed M Dardeer; William E Moody; Nicola C Edwards; Lucy E Hudsmith; Richard P Steeds
Journal:  Int J Cardiol       Date:  2017-10-31       Impact factor: 4.164

10.  Myocardial strain assessed by feature tracking cardiac magnetic resonance in patients with a variety of cardiovascular diseases - A comparison with echocardiography.

Authors:  Kasper Pryds; Anders Hostrup Larsen; Mona Sahlholdt Hansen; Anne Yoon Krogh Grøndal; Rasmus Stilling Tougaard; Nils Henrik Hansson; Tor Skibsted Clemmensen; Brian Bridal Løgstrup; Henrik Wiggers; Won Yong Kim; Hans Erik Bøtker; Roni Ranghøj Nielsen
Journal:  Sci Rep       Date:  2019-08-05       Impact factor: 4.379

View more
  1 in total

1.  A head-to-head comparison of fast-SENC and feature tracking to LV long axis strain for assessment of myocardial deformation in chest pain patients.

Authors:  Deborah Siry; Johannes Riffel; Janek Salatzki; Florian André; Lukas Damian Weberling; Marco Ochs; Noura A Atia; Elizabeth Hillier; David Albert; Hugo A Katus; Evangelos Giannitsis; Norbert Frey; Matthias G Friedrich
Journal:  BMC Med Imaging       Date:  2022-09-05       Impact factor: 2.795

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.