Literature DB >> 25476974

Dentinal crack formation during root canal preparations by the twisted file adaptive, ProTaper Next, ProTaper Universal, and WaveOne instruments.

Ertuğrul Karataş1, Hicran Ateş Gündüz2, Damla Özsu Kırıcı2, Hakan Arslan2, Meltem Çolak Topçu2, Kübra Yeşildal Yeter2.   

Abstract

INTRODUCTION: The aim of this study was to compare the incidence of root cracks after root canal instrumentation with the TF Adaptive, WaveOne, ProTaper Next, and ProTaper Universal systems.
METHODS: Seventy-five extracted mandibular central incisors with mature apices and straight root canals (<5°) were selected and kept in distilled water. The root canals were instrumented by using the ProTaper Universal, ProTaper Next, WaveOne, and TF Adaptive systems. All the roots were horizontally sectioned 3, 6, and 9 mm from the apex with a low-speed saw under water cooling. The slices were then viewed through a stereomicroscope at ×25 magnification. The samples were photographed with a camera to determine the presence of dentinal cracks.
RESULTS: The control group had no cracks, and the difference between the control group and the experimental groups was statistically significant (P < .001). The ProTaper Next and TF Adaptive systems produced significantly less cracks than the ProTaper Universal and WaveOne systems in the apical section (3 mm) (P < .05).
CONCLUSIONS: Under the study conditions and within the limitations of this study, it can be concluded that the ProTaper Universal, ProTaper Next, WaveOne, and TF Adaptive instruments can result in dentinal cracks.
Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dentinal crack; ProTaper Next; Twisted File Adaptive

Mesh:

Year:  2014        PMID: 25476974     DOI: 10.1016/j.joen.2014.10.019

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  24 in total

1.  Shaping ability of two nickel-titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study.

Authors:  E Pedullà; G Plotino; N M Grande; G Avarotti; G Gambarini; E Rapisarda; F Mannocci
Journal:  Clin Oral Investig       Date:  2016-02-15       Impact factor: 3.573

2.  The existence of butterfly effect and its impact on the dentinal microhardness and crack formation after root canal instrumentation.

Authors:  Galvin Sim Siang Lin; Nik Rozainah Nik Abdul Ghani; Tahir Yusuf Noorani
Journal:  Odontology       Date:  2021-01-17       Impact factor: 2.634

3.  Unprepared surface areas, accumulated hard tissue debris, and dentinal crack formation after preparation using reciprocating or rotary instruments: a study in human cadavers.

Authors:  Andrea F Campello; Marília F Marceliano-Alves; José F Siqueira; Simone C Fonseca; Ricardo T Lopes; Flávio R F Alves
Journal:  Clin Oral Investig       Date:  2021-04-26       Impact factor: 3.573

4.  Incidence of microcracks in maxillary first premolars after instrumentation with three different mechanized file systems: a comparative ex vivo study.

Authors:  A Kfir; D Elkes; A Pawar; A Weissman; I Tsesis
Journal:  Clin Oral Investig       Date:  2016-03-30       Impact factor: 3.573

5.  Safe way for using NiTi rotary files.

Authors:  Seok-Woo Chang
Journal:  Restor Dent Endod       Date:  2015-02

6.  Dentinal crack formation during root canal preparations by the twisted file adaptive, Reciproc and WaveOne instruments.

Authors:  Richard M Gergi; Nada E Osta; Alfred S Naaman
Journal:  Eur J Dent       Date:  2015 Oct-Dec

7.  Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use.

Authors:  Gianluca Gambarini; Lucila Piasecki; Dario Di Nardo; Gabriele Miccoli; Gianni Di Giorgio; Everdan Carneiro; Dina Al-Sudani; Luca Testarelli
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

8.  Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study.

Authors:  Galvin Sim Siang Lin; Kiran Prabhakar Singbal; Tahir Yusuf Noorani; Raghavendra Penukonda
Journal:  Odontology       Date:  2021-07-16       Impact factor: 2.634

9.  Influence of a glide path on the dentinal crack formation of ProTaper Next system.

Authors:  Sevinç Aktemur Türker; Emel Uzunoğlu
Journal:  Restor Dent Endod       Date:  2015-09-02

10.  Evaluation of dentinal defects during root canal preparation using thermomechanically processed nickel-titanium files.

Authors:  Bertan Kesim; Burak Sagsen; Tugrul Aslan
Journal:  Eur J Dent       Date:  2017 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.