Literature DB >> 33549871

Feasibility and Safety of Tethered Capsule Endomicroscopy in Patients With Barrett's Esophagus in a Multi-Center Study.

Jing Dong1, Catriona Grant2, Barry Vuong1, Norman Nishioka1, Anna Huizi Gao2, Matthew Beatty2, Grace Baldwin2, Aaron Baillargeon2, Ara Bablouzian2, Patricia Grahmann2, Nitasha Bhat2, Emily Ryan2, Amilcar Barrios2, Sarah Giddings2, Timothy Ford1, Emilie Beaulieu-Ouellet2, Seyed Hamid Hosseiny2, Irene Lerman2, Wolfgang Trasischker1, Rohith Reddy1, Kanwarpal Singh1, Michalina Gora3, Daryl Hyun2, Lucille Quénéhervé1, Michael Wallace4, Herbert Wolfsen4, Prateek Sharma5, Kenneth K Wang6, Cadman L Leggett6, John Poneros7, Julian A Abrams7, Charles Lightdale7, Samantha Leeds7, Mireille Rosenberg1, Guillermo J Tearney8.   

Abstract

BACKGROUND & AIMS: Tethered capsule endomicroscopy (TCE) involves swallowing a small tethered pill that implements optical coherence tomography (OCT) imaging, procuring high resolution images of the whole esophagus. Here, we demonstrate and evaluate the feasibility and safety of TCE and a portable OCT imaging system in patients with Barrett's esophagus (BE) in a multi-center (5-site) clinical study.
METHODS: Untreated patients with BE as per endoscopic biopsy diagnosis were eligible to participate in the study. TCE procedures were performed in unsedated patients by either doctors or nurses. After the capsule was swallowed, the device continuously obtained 10-μm-resolution cross-sectional images as it traversed the esophagus. Following imaging, the device was withdrawn through mouth, and disinfected for subsequent reuse. BE lengths were compared to endoscopy findings when available. OCT-TCE images were compared to volumetric laser endomicroscopy (VLE) images from a patient who had undergone VLE on the same day as TCE.
RESULTS: 147 patients with BE were enrolled across all sites. 116 swallowed the capsule (79%), 95/114 (83.3%) men and 21/33 (63.6%) women (P = .01). High-quality OCT images were obtained in 104/111 swallowers (93.7%) who completed the procedure. The average imaging duration was 5.55 ± 1.92 minutes. The mean length of esophagus imaged per patient was 21.69 ± 5.90 cm. A blinded comparison of maximum extent of BE measured by OCT-TCE and EGD showed a strong correlation (r = 0.77-0.79). OCT-TCE images were of similar quality to those obtained by OCT-VLE.
CONCLUSIONS: The capabilities of TCE to be used across multiple sites, be administered to unsedated patients by either physicians or nurses who are not expert in OCT-TCE, and to rapidly and safely evaluate the microscopic structure of the esophagus make it an emerging tool for screening and surveillance of BE patients. Clinical trial registry website and trial number: NCT02994693 and NCT03459339.
Copyright © 2022 AGA Institute. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Barrett’s Esophagus; Optical Coherence Tomography; Tethered Capsule Endomicroscopy

Mesh:

Year:  2021        PMID: 33549871      PMCID: PMC8715859          DOI: 10.1016/j.cgh.2021.02.008

Source DB:  PubMed          Journal:  Clin Gastroenterol Hepatol        ISSN: 1542-3565            Impact factor:   11.382


  41 in total

1.  Identifying intestinal metaplasia at the squamocolumnar junction by using optical coherence tomography.

Authors:  John A Evans; Brett E Bouma; Jason Bressner; Milen Shishkov; Gregory Y Lauwers; Mari Mino-Kenudson; Norman S Nishioka; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2006-09-20       Impact factor: 9.427

2.  Standard endoscopy with random biopsies versus narrow band imaging targeted biopsies in Barrett's oesophagus: a prospective, international, randomised controlled trial.

Authors:  Prateek Sharma; Robert H Hawes; Ajay Bansal; Neil Gupta; Wouter Curvers; Amit Rastogi; Mandeep Singh; Matt Hall; Sharad C Mathur; Sachin B Wani; Brenda Hoffman; Srinivas Gaddam; Paul Fockens; Jacques J Bergman
Journal:  Gut       Date:  2012-02-07       Impact factor: 23.059

Review 3.  Chromoendoscopy.

Authors:  Louis Michel Wong Kee Song; Douglas G Adler; Bipan Chand; Jason D Conway; Joseph M B Croffie; James A Disario; Daniel S Mishkin; Raj J Shah; Lehel Somogyi; William M Tierney; Bret T Petersen
Journal:  Gastrointest Endosc       Date:  2007-07-23       Impact factor: 9.427

4.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

5.  Detection of buried Barrett's glands after radiofrequency ablation with volumetric laser endomicroscopy.

Authors:  Anne-Fré Swager; David F Boerwinkel; Daniel M de Bruin; Dirk J Faber; Ton G van Leeuwen; Bas L Weusten; Sybren L Meijer; Jacques J Bergman; Wouter L Curvers
Journal:  Gastrointest Endosc       Date:  2015-06-26       Impact factor: 9.427

6.  Safety and feasibility of volumetric laser endomicroscopy in patients with Barrett's esophagus (with videos).

Authors:  Herbert C Wolfsen; Prateek Sharma; Michael B Wallace; Cadman Leggett; Guillermo Tearney; Kenneth K Wang
Journal:  Gastrointest Endosc       Date:  2015-05-06       Impact factor: 9.427

7.  Tethered capsule endomicroscopy for microscopic imaging of the esophagus, stomach, and duodenum without sedation in humans (with video).

Authors:  Michalina J Gora; Lucille Quénéhervé; Robert W Carruth; Weina Lu; Mireille Rosenberg; Jenny S Sauk; Alessio Fasano; Gregory Y Lauwers; Norman S Nishioka; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2018-07-19       Impact factor: 9.427

8.  Is the risk of concomitant invasive esophageal cancer in high-grade dysplasia in Barrett's esophagus overestimated?

Authors:  Vani J A Konda; Andrew S Ross; Mark K Ferguson; John A Hart; Shang Lin; Keith Naylor; Amy Noffsinger; Mitchell C Posner; Charles Dye; Barbara Cislo; Lynne Stearns; Irving Waxman
Journal:  Clin Gastroenterol Hepatol       Date:  2007-12-21       Impact factor: 11.382

9.  ACG Clinical Guideline: Diagnosis and Management of Barrett's Esophagus.

Authors:  Nicholas J Shaheen; Gary W Falk; Prasad G Iyer; Lauren B Gerson
Journal:  Am J Gastroenterol       Date:  2015-11-03       Impact factor: 10.864

10.  Incremental yield of dysplasia detection in Barrett's esophagus using volumetric laser endomicroscopy with and without laser marking compared with a standardized random biopsy protocol.

Authors:  Mohammad Alshelleh; Sumant Inamdar; Matthew McKinley; Molly Stewart; Jeffrey S Novak; Ronald E Greenberg; Keith Sultan; Bethany Devito; Mary Cheung; Maurice A Cerulli; Larry S Miller; Divyesh V Sejpal; Anil K Vegesna; Arvind J Trindade
Journal:  Gastrointest Endosc       Date:  2018-02-02       Impact factor: 9.427

View more
  3 in total

1.  High-Resolution Ex-Vivo Imaging of Retina with a Laptop-Based Portable Endoscope.

Authors:  Yanni Ge; Kai Jin; Yao Wang; Yufeng Xu; Haitong Lu; Juan Ye
Journal:  J Ophthalmol       Date:  2022-04-11       Impact factor: 1.974

Review 2.  Expanding beyond endoscopy: A review of non-invasive modalities in Barrett's esophagus screening and surveillance.

Authors:  Dariush Shahsavari; Praneeth Kudaravalli; John Erikson L Yap; Kenneth J Vega
Journal:  World J Gastroenterol       Date:  2022-08-28       Impact factor: 5.374

3.  Passively scanned, single-fiber optical coherence tomography probes for gastrointestinal devices.

Authors:  David O Otuya; Nicholas M Dechene; Darina Poshtupaka; Seth Judson; Camella J Carlson; Sarah K Zemlok; Evan Sevieri; Peter Choy; Rachel E Shore; Esmarline De León-Peralta; Alissa A Cirio; Tyler W Rihm; Alexander A Krall; Evangelia Gavgiotaki; Jing Dong; Sarah L Silva; Aaron Baillargeon; Grace Baldwin; Anna H Gao; Zachary Jansa; Amilcar Barrios; Emily Ryan; Nitasha G M Bhat; Indira Balmasheva; Anita Chung; Catriona N Grant; Ara L Bablouzian; Matthew Beatty; Osman O Ahsen; Hui Zheng; Guillermo J Tearney
Journal:  Lasers Surg Med       Date:  2022-06-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.