Literature DB >> 33542967

Comparison of Correction Techniques for the Spill in Effect in Emission Tomography.

Mercy I Akerele1, Nicolas A Karakatsanis2, Daniel Deidda3, Jacobo Cal-Gonzalez4, Rachael O Forsythe5, Marc R Dweck5, Maaz Syed5, David E Newby5, Robert G Aykroyd6, Steven Sourbron7, Charalampos Tsoumpas8.   

Abstract

In positron emission tomography (PET) imaging, accurate clinical assessment is often affected by the partial volume effect (PVE) leading to overestimation (spill-in) or underestimation (spill-out) of activity in various small regions. The spill-in correction, in particular, can be very challenging when the target region is close to a hot background region. Therefore, this study evaluates and compares the performance of various recently developed spill-in correction techniques, namely: background correction (BC), local projection (LP), and hybrid kernelized (HKEM) methods. We used a simulated digital phantom and [18F]-NaF PET data of three patients with abdominal aortic aneurysms (AAA) acquired with Siemens Biograph mMR™ and mCT™ scanners respectively. Region of Interest (ROI) analysis was performed and the extracted SUV mean , SUV max and target-to-background ratio (TBR) scores were compared. Results showed substantial spill-in effects from hot regions to targeted regions, which are more prominent in small structures. The phantom experiment demonstrated the feasibility of spill-in correction with all methods. For the patient data, large differences in SUV mean , SUV max and TBR max scores were observed between the ROIs drawn over the entire aneurysm and ROIs excluding some regions close to the bone. Overall, BC yielded the best performance in spill-in correction in both phantom and patient studies.

Entities:  

Keywords:  PET; PVE; SPECT; quantification; spill-in effect

Year:  2020        PMID: 33542967      PMCID: PMC7116684          DOI: 10.1109/TRPMS.2020.2980443

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  32 in total

1.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

Review 2.  A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology.

Authors:  Kjell Erlandsson; Irène Buvat; P Hendrik Pretorius; Benjamin A Thomas; Brian F Hutton
Journal:  Phys Med Biol       Date:  2012-10-16       Impact factor: 3.609

3.  Improved regional activity quantitation in nuclear medicine using a new approach to correct for tissue partial volume and spillover effects.

Authors:  Stephen C Moore; Sudeepti Southekal; Mi-Ae Park; Sarah J McQuaid; Marie Foley Kijewski; Stefan P Müller
Journal:  IEEE Trans Med Imaging       Date:  2011-09-29       Impact factor: 10.048

4.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

5.  Quantitative comparison of PET performance-Siemens Biograph mCT and mMR.

Authors:  Anna M Karlberg; Oddbjørn Sæther; Live Eikenes; Pål Erik Goa
Journal:  EJNMMI Phys       Date:  2016-02-25

6.  Optimization and Reproducibility of Aortic Valve 18F-Fluoride Positron Emission Tomography in Patients With Aortic Stenosis.

Authors:  Tania A Pawade; Timothy R G Cartlidge; William S A Jenkins; Philip D Adamson; Phillip Robson; Christophe Lucatelli; Edwin J R Van Beek; Bernard Prendergast; Alan R Denison; Laura Forsyth; James H F Rudd; Zahi A Fayad; Alison Fletcher; Sharon Tuck; David E Newby; Marc R Dweck
Journal:  Circ Cardiovasc Imaging       Date:  2016-10       Impact factor: 7.792

7.  Point-spread function reconstructed PET images of sub-centimeter lesions are not quantitative.

Authors:  O L Munk; L P Tolbod; S B Hansen; T V Bogsrud
Journal:  EJNMMI Phys       Date:  2017-01-13

8.  Validation of the physiological background correction method for the suppression of the spill-in effect near highly radioactive regions in positron emission tomography.

Authors:  Mercy I Akerele; Palak Wadhwa; Jesus Silva-Rodriguez; William Hallett; Charalampos Tsoumpas
Journal:  EJNMMI Phys       Date:  2018-12-05

9.  Invalidity of SUV Measurements of Lesions in Close Proximity to Hot Sources due to "Shine-Through" Effect on FDG PET-CT Interpretation.

Authors:  Yiyan Liu
Journal:  Radiol Res Pract       Date:  2012-10-14

10.  Identifying active vascular microcalcification by (18)F-sodium fluoride positron emission tomography.

Authors:  Agnese Irkle; Alex T Vesey; David Y Lewis; Jeremy N Skepper; Joseph L E Bird; Marc R Dweck; Francis R Joshi; Ferdia A Gallagher; Elizabeth A Warburton; Martin R Bennett; Kevin M Brindle; David E Newby; James H Rudd; Anthony P Davenport
Journal:  Nat Commun       Date:  2015-07-07       Impact factor: 14.919

View more
  4 in total

1.  Improved identification of abdominal aortic aneurysm using the Kernelized Expectation Maximization algorithm.

Authors:  Daniel Deidda; Mercy I Akerele; Robert G Aykroyd; Marc R Dweck; Kelley Ferreira; Rachael O Forsythe; Warda Heetun; David E Newby; Maaz Syed; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-05-10       Impact factor: 4.226

2.  Hybrid kernelised expectation maximisation for Bremsstrahlung SPECT reconstruction in SIRT with 90Y micro-spheres.

Authors:  Daniel Deidda; Ana M Denis-Bacelar; Andrew J Fenwick; Kelley M Ferreira; Warda Heetun; Brian F Hutton; Andrew P Robinson; James Scuffham; Kris Thielemans
Journal:  EJNMMI Phys       Date:  2022-04-04

3.  Voxelwise Principal Component Analysis of Dynamic [S-Methyl-11C]Methionine PET Data in Glioma Patients.

Authors:  Corentin Martens; Olivier Debeir; Christine Decaestecker; Thierry Metens; Laetitia Lebrun; Gil Leurquin-Sterk; Nicola Trotta; Serge Goldman; Gaetan Van Simaeys
Journal:  Cancers (Basel)       Date:  2021-05-12       Impact factor: 6.639

4.  Assessment of different quantification metrics of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm.

Authors:  Mercy I Akerele; Nouf A Mushari; Rachael O Forsythe; Maaz Syed; Nicolas A Karakatsanis; David E Newby; Marc R Dweck; Charalampos Tsoumpas
Journal:  J Nucl Cardiol       Date:  2020-06-17       Impact factor: 3.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.