Literature DB >> 3354039

Platelet membrane glycoprotein changes during the preparation and storage of platelet concentrates.

J N George1, E B Pickett, R Heinz.   

Abstract

Previous studies of platelet membrane glycoproteins during blood bank storage have reported conflicting results. This study assessed two major plasma membrane glycoproteins (GP Ib and GP IIb), an alpha-granule membrane protein (GMP-140), and the concentration of platelet membrane microparticles in cell-free plasma during routine hospital blood bank platelet storage. 125I-monoclonal antibody binding was used to measure membrane glycoproteins on the surface of intact platelets and to measure the concentration of membrane microparticles in cell-free plasma. Platelet concentrates were stored at room temperature in polyolefin bags for 7 days. In this blood bank, two types of rotators are routinely used for platelet concentrate storage: a 2-rpm circular tumbler rotator and a 6-rpm elliptical rotator. Different results were obtained with the rotators. With the tumbler rotator, there was no loss of platelets and antibody binding to GP Ib remained normal. With the elliptical rotator, one third of platelets were lost into clumps during storage, and a 50 percent decrease of antibody binding to GP Ib occurred in the remaining single platelets. There was no loss of antibody binding to GP IIb with either rotator. Antibody binding to GMP-140 increased equally in both rotators indicating that the remaining single platelets had secreted about 16 percent of their alpha-granule contents. The plasma concentration of platelet membrane microparticles was greater in the bags stored in the elliptical rotator. These results indicate that it is possible to maintain the normal concentration of platelet membrane glycoproteins Ib and IIb during 7 days of room-temperature blood bank storage.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3354039     DOI: 10.1046/j.1537-2995.1988.28288179014.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  8 in total

Review 1.  Infusible platelet membrane as a platelet substitute for transfusion: an overview.

Authors:  Saleh Nasiri
Journal:  Blood Transfus       Date:  2013-05-14       Impact factor: 3.443

Review 2.  Cell-derived microparticles in stored blood products: innocent-bystanders or effective mediators of post-transfusion reactions?

Authors:  Anastasios Kriebardis; Marianna Antonelou; Konstantinos Stamoulis; Issidora Papassideri
Journal:  Blood Transfus       Date:  2012-05       Impact factor: 3.443

3.  Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.

Authors:  Anastasios G Kriebardis; Marianna H Antonelou; Hara T Georgatzakou; Vassilis L Tzounakas; Konstantinos E Stamoulis; Issidora S Papassideri
Journal:  Blood Transfus       Date:  2016-02-22       Impact factor: 3.443

4.  Quality of pooled platelet concentrates prepared from buffy coats and stored in an additive solution after filtration.

Authors:  K Koerner; R Weihe; P Sahlmen; B Zeller; E Seifried; M Cardoso; B Kubanek
Journal:  Ann Hematol       Date:  1995-02       Impact factor: 3.673

5.  Storage lesion of human platelets as revealed by ultrathin sections and freeze-fracture replicas.

Authors:  M H Klinger; A S Mendoza; H Klüter; H J Krammer; W Kühnel
Journal:  Cell Tissue Res       Date:  1994-06       Impact factor: 5.249

6.  Six hours of resting platelet concentrates stored at 22-24 ºC for 48 hours in permeable bags preserved pH, swirling and lactate dehydrogenase better and caused less platelet activation.

Authors:  Hossin T Naghadeh; Bahram A Badlou; Ali S Ferizhandy; Tabatabai S Mohammadreza; Vaeli Shahram
Journal:  Blood Transfus       Date:  2012-10-29       Impact factor: 3.443

Review 7.  Biomarker analysis of stored blood products: emphasis on pre-analytical issues.

Authors:  Julien Delobel; Olivier Rubin; Michel Prudent; David Crettaz; Jean-Daniel Tissot; Niels Lion
Journal:  Int J Mol Sci       Date:  2010-11-17       Impact factor: 5.923

8.  Agitation-dependent biomechanical forces modulate GPVI receptor expression and platelet adhesion capacity during storage.

Authors:  Ehteramolsadat Hosseini; Amin Solouki; Masood Haghshenas; Mehran Ghasemzadeh; Simone M Schoenwaelder
Journal:  Thromb J       Date:  2022-01-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.