Literature DB >> 33536857

Agreement and Reliability of Median Neurodynamic Test 1 and Resting Scapular Position.

Sean P Riley1, Jason K Grimes1, Kylie Calandra1, Kelsey Foster1, Melissa Peet1, Matthew T Walsh1.   

Abstract

OBJECTIVE: The purposes of this study were to determine whether there are differences between the dominant and nondominant arms for the Median Neurodynamic Test 1 (MNT 1); whether there are differences between men and women on the MNT 1; the reliability of an assessment of resting scapular position; the reliability of the MNT 1; and the frequency and percentage of sensory responses that are present during the MNT 1 in the asymptomatic population.
METHODS: This was a reliability and agreement study. It included asymptomatic students enrolled in the college of health professions and the college of nursing at a university. The Mann-Whitney U was used to determine whether there were any differences between the dominant and nondominant sides and between sexes for elbow extension range of motion and for sensory responses on the numeric pain rating scale when performing the MNT 1. A χ2 analysis was used to determine whether there were any differences between sexes and between dominant and nondominant upper extremities for sensory-response location, sensory-response type, and structural differentiation for raters 1 and 2. The intraclass correlation coefficient (ICC2,3) was used to determine the intertester and intratester reliability for the degrees of elbow extension attained during testing.
RESULTS: Reliability for degrees of elbow extension and strength of the sensory response was excellent (ICC2,3 ˃ 0.75) and substantial (κ ≥ 0.68), respectively. Resting scapular position and all other components of the MNT 1 demonstrated statistically significant side-to-side differences and κ values ranging from 0.23 to 0.88.
CONCLUSION: Elbow extension and magnitude of sensory response are reliable components of the MNT 1 that are not different between the dominant and nondominant sides in the asymptomatic population.
© 2020 by National University of Health Sciences.

Entities:  

Keywords:  Median Nerve; Reproducibility of Results; Upper Extremity

Year:  2021        PMID: 33536857      PMCID: PMC7835492          DOI: 10.1016/j.jcm.2020.09.002

Source DB:  PubMed          Journal:  J Chiropr Med        ISSN: 1556-3707


  31 in total

Review 1.  The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.

Authors:  Robert J Nee; Gwendolen A Jull; Bill Vicenzino; Michel W Coppieters
Journal:  J Orthop Sports Phys Ther       Date:  2012-03-08       Impact factor: 4.751

2.  Common interlimb asymmetries and neurogenic responses during upper limb neurodynamic testing: implications for test interpretation.

Authors:  Benjamin S Boyd
Journal:  J Hand Ther       Date:  2011-11-12       Impact factor: 1.950

3.  Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed.

Authors:  Jan Kottner; Laurent Audigé; Stig Brorson; Allan Donner; Byron J Gajewski; Asbjørn Hróbjartsson; Chris Roberts; Mohamed Shoukri; David L Streiner
Journal:  J Clin Epidemiol       Date:  2010-06-17       Impact factor: 6.437

4.  Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses.

Authors:  G Rankin; M Stokes
Journal:  Clin Rehabil       Date:  1998-06       Impact factor: 3.477

Review 5.  Physical evaluation of the peripheral nervous system in disorders of pain and dysfunction.

Authors:  R L Elvey
Journal:  J Hand Ther       Date:  1997 Apr-Jun       Impact factor: 1.950

6.  The influence of a depressed scapular alignment on upper limb neural tissue mechanosensitivity and local pressure pain sensitivity.

Authors:  Patricia Martínez-Merinero; Enriqe Lluch; Tomas Gallezo-Izquierdo; Daniel Pecos-Martín; Gustavo Plaza-Manzano; Susana Nuñez-Nagy; Deborah Falla
Journal:  Musculoskelet Sci Pract       Date:  2017-03-10       Impact factor: 2.520

7.  Clinical trial registration in physiotherapy journals: recommendations from the International Society of Physiotherapy Journal Editors.

Authors: 
Journal:  J Man Manip Ther       Date:  2013-02

8.  The Frankfort horizontal as a basis for cephalometric analysis.

Authors:  A Lundström; F Lundström
Journal:  Am J Orthod Dentofacial Orthop       Date:  1995-05       Impact factor: 2.650

9.  Development of a clinical prediction rule for the diagnosis of carpal tunnel syndrome.

Authors:  Robert S Wainner; Julie M Fritz; James J Irrgang; Anthony Delitto; Stephen Allison; Michael L Boninger
Journal:  Arch Phys Med Rehabil       Date:  2005-04       Impact factor: 3.966

10.  Ulnar nerve neurodynamic test: study of the normal sensory response in asymptomatic individuals.

Authors:  Maria Dolores Arguisuelas Martínez; Carlos López Cubas; Enrique Lluch Girbés
Journal:  J Orthop Sports Phys Ther       Date:  2014-05-10       Impact factor: 4.751

View more
  1 in total

1.  Quantifying the Elasticity Properties of the Median Nerve during the Upper Limb Neurodynamic Test 1.

Authors:  Ming Lin; Yaodong Chen; Weixin Deng; Hongying Liang; Suiqing Yu; Zhijie Zhang; Chunlong Liu
Journal:  Appl Bionics Biomech       Date:  2022-03-20       Impact factor: 1.781

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.