Literature DB >> 33517139

Effectiveness of synthetic aperture focusing and coherence factor weighting for intravascular ultrasound imaging.

Sungwoo Kang1, Junsu Lee1, Jin Ho Chang2.   

Abstract

Synthetic aperture focusing (SAF) and coherence factor weighting (CFW) have been used to improve the lateral resolution of ultrasound images. Although the two methods are effective for array-based ultrasound imaging, many researchers have also employed the methods for single-element-based imaging including intravascular ultrasound (IVUS) imaging. For single-element-based imaging, CFW is generally calculated from the scanlines obtained by SAF and applied to the scanline obtained after coherent summation of the SAF delayed scanlines, which is called a SAF-CFW method. In the paper, a theoretical model was derived to explore the effectiveness of SAF and CFW for single-element-based imaging, and the model was used to explain that SAF is not effective for IVUS imaging in terms of enhancing the spatial resolution, although it has the advantage of improving a contrast-to-noise ratio (CNR). This means that the SAF-CFW method is not optimal for improving the spatial resolution of IVUS imaging. In contrast, it was found in simulations and experiments that applying CFW to the target scanline itself is beneficial for the spatial resolution rather than a coherent summed scanline for IVUS SAF imaging, but CNR was not as good as SAF and SAF-CFW. As a result of both simulation and experimentation, it could be concluded that focused IVUS transducers without the application of those methods may be more advantageous to improve the spatial and contrast resolution simultaneously, considering the system complexity in the implementation of such imaging methods.
Copyright © 2021 Elsevier B.V. All rights reserved.

Keywords:  Coherence factor; High frequency transducer; Intravascular Ultrasound (IVUS) imaging; Synthetic aperture focusing; Ultrasonic imaging

Year:  2021        PMID: 33517139     DOI: 10.1016/j.ultras.2021.106364

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  2 in total

1.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

2.  A novel design framework of synthetic radial aperture focusing for volumetric transrectal ultrasound imaging.

Authors:  Hyunwoo Song; Jeeun Kang; Emad M Boctor
Journal:  J Comput Des Eng       Date:  2022-08-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.