Literature DB >> 33514161

Sensitivity and specificity of a method for diagnosis of military noise-induced hearing loss.

Brian C J Moore1, Petra von Gablenz2.   

Abstract

Moore [(2020). J. Acoust. Soc. Am. 148, 884-894] proposed a method for the diagnosis of hearing loss produced by noise exposure during military service (denoted M-NIHL) based on the audiogram. This letter characterizes the sensitivity and specificity of the method, based on 116 ears of men claiming compensation for M-NIHL and 244 ears of an age-matched non-noise-exposed control group of men screened to match the noise-exposed group in age, absence of conductive hearing loss, no history of ear diseases, and asymmetry across ears ≤10 dB. The sensitivity was 0.97 and the specificity was 0.67, giving a discriminability index d' of 2.3.

Entities:  

Mesh:

Year:  2021        PMID: 33514161     DOI: 10.1121/10.0002977

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  2 in total

1.  Guidelines for Diagnosing and Quantifying Noise-Induced Hearing Loss.

Authors:  Brian C J Moore; David A Lowe; Graham Cox
Journal:  Trends Hear       Date:  2022 Jan-Dec       Impact factor: 3.496

Review 2.  Prevention of Noise-Induced Hearing Loss Using Investigational Medicines for the Inner Ear: Previous Trial Outcomes Should Inform Future Trial Design.

Authors:  Colleen G Le Prell
Journal:  Antioxid Redox Signal       Date:  2021-10-04       Impact factor: 7.468

  2 in total