| Literature DB >> 33512660 |
Andrew W Downey1, Laura V Duggan2, J Adam Law3.
Abstract
PURPOSE: In the preceding 20 years, many randomized-controlled trials and meta-analyses have compared direct Macintosh laryngoscopy with videolaryngoscopy. The videolaryngoscope blades have included both traditional Macintosh blades and hyperangulated blades. Macintosh and hyperangulated blades differ in their geometry and technique for tracheal intubation; certain patient populations may benefit from one blade type over another. The primary objective of this systematic review was to assess whether published meta-analyses comparing direct Macintosh laryngoscopy to videolaryngoscopy have accounted for the videolaryngoscope blade type. Secondary objectives evaluated heterogeneity among practitioner experience and specialty, clinical context, patient population, and original primary study outcomes. SOURCE: A search was performed across Ovid Medline, Ovid Embase, ClinicalKey, PubMed, TRIP, AccessAnesthesiology, Google Scholar, and ANZCA discovery. A systematic review identified meta-analyses which compared direct Macintosh laryngoscopy to videolaryngoscopy. There were no patient age or clinical specialty restrictions. Exclusion criteria included non-English language, studies comparing non-Macintosh blade to videolaryngoscopy, and studies in awake patients. PRINCIPALEntities:
Keywords: Macintosh laryngoscopy; direct laryngoscopy; hyperangulated blade; meta-analysis; videolaryngoscopy
Mesh:
Year: 2021 PMID: 33512660 PMCID: PMC7845281 DOI: 10.1007/s12630-021-01921-7
Source DB: PubMed Journal: Can J Anaesth ISSN: 0832-610X Impact factor: 6.713
Fig. 2PRISMA flow diagram of systematic review process.
Comparison of meta-analyses based on single or multiple VL blade type and clinician and patient factors
| Publication | Multiple VL blades | Mixed practitioner experience | Mixed practitioner speciality | Location (ED/ICU/OR/pre hospital/multiple) | Difficult airways only | Patient population |
|---|---|---|---|---|---|---|
| Jiang 2019 | Y | Y | N | OR | N | Adults |
| Arulkumaran 2018 | Y | Y | Y | Multiple | N | Adults |
| Bhattacharjee 2018 | Y | Y | Y | ED | N | Adults |
| Hoshijima 2018 | Y | Y | Y | OR | N | Adults |
| Hoshijima 2018 | N | Y* | N | OR | N | Adults |
| Hoshijima 2018 | Y | Y | Y | Multiple | N | Adults |
| Hoshijima 2018 | Y | Y | Y | Multiple | N | Adult |
| Liu 2018 | Y | Y | N | OR | N | Adults |
| Huang 2017 | Y | Y | Y | ICU | N | Adults |
| Jiang 2017 | Y | Y | Y | Multiple | N | Adults |
| Pieters 2017 | Y | N | N | OR | Y | Adults |
| Savino 2017 | Y | Y | Y | Prehospital | N | All ages |
| Zhao 2017 | Y | Y | Y | ICU | N | Not defined |
| Lewis 2016 | Y | Y | Y | Multiple | N | Adults |
| De Jong 2014 | Y | Y | Y | ICU | N | Adults |
| Hoshijima 2014 | N | Y | Y | Multiple | N | Adults |
| Lee 2012 | Y | Y | Y | Multiple | N | All ages |
| Griesdale 2012 | N | Y | Y | Multiple | N | Adults |
| Lu 2011 | N | Y | N | Not defined | N | Not defined |
| Su 2011 | Y | Y | N | OR | N | All ages |
| Mihai 2008^ | N | Y | Y | Not defined | N^ | Adults |
*Presumed mixed experience as not documented in three studies included in this meta-analysis.
^Videolaryngoscopes were considered individually, difficult airways considered in other parts of publication but not in relation to VL vs Macintosh.
ED = emergency department; ICU= intensive care unit; OR = operating room; VL = videolaryngoscopy.
Primary outcome of meta-analyses with VL blade (either single blade described or multiple) and outcome (if primary outcome described)
| Publication | Year | Meta-analysis outcome | Outcome result |
|---|---|---|---|
| Jiang | 2019 | 1° outcome: overall success: VL (multiple types) | No difference |
| Arulkumaran | 2018 | 1° outcome: first attempt intubation: VL (multiple types) | No difference |
| Bhattacharjee | 2018 | 1° outcome: first attempt success: VL (multiple types) | No difference |
| Hoshijima | 2018 | 1° outcome: overall success: VL (multiple types) | Improved success |
| Hoshijima | 2018 | 1° outcome: haemodynamic response 60 sec after laryngoscopy: VL (Airtraq) | Reduced HR and MAP |
| Hoshijima | 2018 | Multiple outcomes, 1° outcome not defined: VL (multiple types) | NA |
| Hoshijima | 2018 | Multiple outcomes, 1° outcome not defined: VL (multiple types) | NA |
| Liu | 2018 | 1° outcome: first attempt success: VL (multiple types including optical stylet) | Improved success |
| Huang | 2017 | 1° outcome: first attempt success rate: VL (multiple types) | No difference |
| Jiang | 2017 | 1° outcome: first attempt success rate: VL (multiple types) | No difference |
| Pieters | 2017 | Multiple outcomes: 1° outcome not defined: VL (multiple types) | NA |
| Savino | 2017 | Multiple outcomes, 1° outcome not defined: VL (multiple types) | NA |
| Zhao | 2017 | 1° outcome: first attempt success: VL (multiple types) | No difference |
| Lewis | 2016 | 1° outcome: complications & failure: VL (multiple types) | Fewer complications and fewer failed intubations |
| De Jong | 2014 | 1° outcome: difficult tracheal intubation: VL (multiple types) | Fewer difficult intubations |
| Hoshijima | 2014 | Multiple outcomes, 1° outcome not defined: VL (Pentax Airway Scope) | NA |
| Lee | 2012 | Multiple outcomes, 1° outcome not defined: VL (multiple types) | NA |
| Griesdale | 2012 | 1° outcome: glottic view: VL (Glidescope) | Improved glottic view |
| Lu | 2011 | 1° outcome: intubation time and first attempt success rate: VL (Airtraq) | Reduced intubation time, no difference in first attempt success rate |
| Su | 2011 | Multiple outcomes, 1° outcome not defined: VL (multiple types) | NA |
| Mihai | 2008 | Multiple outcomes, 1° outcome not defined: VL (multiple types compared individually) difficult airways considered in other parts of publication but not in relation to VL | NA |
DL = direct laryngoscopy, HR = heart rate, MAP = mean arterial blood pressure; NA = not applicable as 1° outcome not defined; VL= videolaryngoscopy.
Fig. 1Comparison of Macintosh direct laryngoscope (A), videolaryngoscope with Macintosh blade (B), videolaryngoscope with hyperangulated blade (C). Videolaryngoscopes displayed are from the C-MAC system (Karl Storz, Tuttlingen, Germany).
Fig. 3An example of a videolaryngoscope blade with an intermediate angulation (A), i.e., less than a hyperangulated blade but greater than a Macintosh blade (B). The videolaryngoscope displayed is the McGrath system with MAC 3 blade (Medtronic, Minneapolis, MN, USA).
| # | Search statement | Results |
|---|---|---|
| 1 | direct laryngoscop*.mp. | 2338 |
| 2 | Meta-Analysis as Topic/ or meta-analys*.mp. | 177819 |
| 3 | videolaryngoscop*.mp. | 1047 |
| 4 | video laryngoscop*.mp. | 965 |
| 5 | Laryngoscopy.mp. or exp LARYNGOSCOPY/ | 15759 |
| 6 | exp Video Recording/ | 39054 |
| 7 | 3 or 4 or 6 | 40329 |
| 8 | Laryngoscopy/ or Laryngoscopes/ | 14089 |
| 9 | 1 or 8 | 15032 |
| 10 | 3 or 4 or 6 | 40329 |
| 11 | 1 or 8 | 15032 |
| 12 | 1 and 2 and 10 | 17 |
| 13 | 10 and 11 | 2268 |
| 14 | limit 13 to (english language and yr=“2000 -Current”) | 1813 |
| 15 | limit 14 to meta analysis | 21 |
| 16 | 3 or 4 | 1941 |
| 17 | 1 and 16 | 463 |
| 18 | limit 17 to (english language and yr=“2000 -Current”) | 425 |
| 19 | limit 18 to meta analysis | 14 |
| 20 | 8 and 10 | 2151 |
| 21 | limit 20 to (english language and yr=“2000 -Current”) | 1707 |
| 22 | limit 21 to meta analysis | 21 |
| 23 | 2 and 20 | 30 |
| 24 | limit 23 to (english language and yr=“2000 -Current”) | 26 |
| 25 | Glidescope.mp. | 592 |
| 26 | Macintosh.mp. | 1904 |
| 27 | 25 or 26 | 2333 |
| 28 | 2 and 27 | 24 |
| 29 | limit 28 to (english language and yr=“2000 -Current”) | 17 |
| 30 | limit 29 to meta analysis | 14 |
| 31 | limit 27 to meta analysis | 21 |
| 32 | limit 31 to (english language and yr=“2000 -Current”) | 14 |
| 33 | c-mac.mp. | 196 |
| 34 | mcgrath.mp. | 338 |
| 35 | 25 or 26 or 33 or 34 | 2669 |
| 36 | limit 35 to (yr=“2000 -Current” and meta analysis) | 22 |
| 37 | from 32 keep 1-14 | 14 |
| 38 | from 36 keep 1-22 | 22 |
| 39 | 2 and 35 | 26 |
| 40 | 1 or 5 or 8 or 26 | 18541 |
| 41 | 3 or 4 or 6 or 25 or 33 or 34 | 40707 |
| 42 | 40 and 41 | 2683 |
| 43 | 2 and 42 | 34 |
| 44 | Pentax Airway Scope.mp. or exp flexible laryngoscope/ | 43 |
| 45 | 25 or 33 or 34 or 44 | 1085 |
| 46 | 1 or 26 | 3969 |
| 47 | 45 and 46 | 442 |
| 48 | limit 47 to (english language and meta analysis and yr=“2000 -Current”) | 8 |