Literature DB >> 33502555

Percutaneous Sonazoid-enhanced ultrasonography combined with in vitro verification for detection and characterization of sentinel lymph nodes in early breast cancer.

Yunxia Hao1, Yan Sun1, Yutao Lei2, Hongmei Zhao2, Ligang Cui3.   

Abstract

OBJECTIVES: To assess the efficacy of percutaneous Sonazoid-enhanced ultrasound and in vitro verification for identification sentinel lymph nodes (SLNs) and diagnosis of metastatic SLNs in patients with early breast cancer (BC).
METHODS: Sixty-eight patients with early BC were enrolled finally. After the induction of general anesthesia, 0.4 ml of Sonazoid (SNZ), a new second-generation tissue-specific ultrasound contrast agent (UCA), mixed with 0.6 ml of methylene blue, was injected intradermally. The lymphatic vessels and connected SLNs were immediately observed and marked. After being resected, these SLNs were soaked in saline water and examined still in the mode of contrast-enhanced ultrasound (CEUS) in vitro. This procedure could ensure that all the enhanced nodes had been removed as much as possible. The numbers of SLNs detected by UCA and blue dye were recorded. The enhancement patterns of SLNs were compared with the final pathological results.
RESULTS: SLNs detection rate by SNZ-CEUS was 100%, which was higher than that by blue dye (95.59%). CEUS identified a median of 1.5 nodes, while blue dye identified a median of 1.9 nodes per case (p = 0.0012). When homogeneous high perfusion and complete annular high perfusion were regarded as negative nodes, the sensitivity and negative predictive value were 92.31% and 96.79% respectively, while the specificity was 84.21%.
CONCLUSIONS: Percutaneous SNZ-enhanced ultrasonography combined with in vitro verification is a feasible and reliable method for SLNs identification intraoperatively. Enhancement patterns can be helpful in determining the status of SLNs. KEY POINTS: • CEUS with percutaneous injection of Sonazoid can successfully identify SLNs with the rate of 100% in early breast cancer patients, higher than 95.59% of blue dye. • Sonazoid, with high affinity with reticuloendothelial cells, increases the imaging time of SLNs and facilitates biopsy intraoperatively better than Sonovue as a lymphatic tracer. • Homogenous high and complete annular high perfusions have a sensitivity of 92.31% and a negative predictive value of 96.79% in the prediction of uninvolved SLNs.
© 2021. The Author(s).

Entities:  

Keywords:  Breast neoplasms; Contrast media; Sentinel lymph node; Sonazoid; Ultrasonography

Mesh:

Substances:

Year:  2021        PMID: 33502555     DOI: 10.1007/s00330-020-07639-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

1.  Breast cancer in limited-resource countries: an overview of the Breast Health Global Initiative 2005 guidelines.

Authors:  Benjamin O Anderson; Roman Shyyan; Alexandru Eniu; Robert A Smith; Cheng-Har Yip; Nuran Senel Bese; Louis W C Chow; Shahla Masood; Scott D Ramsey; Robert W Carlson
Journal:  Breast J       Date:  2006 Jan-Feb       Impact factor: 2.431

2.  Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization.

Authors:  Rache Simmons; Sarmela Thevarajah; Meghan B Brennan; Paul Christos; Michael Osborne
Journal:  Ann Surg Oncol       Date:  2003-04       Impact factor: 5.344

Review 3.  Blue dye for identification of sentinel nodes in breast cancer and malignant melanoma: a systematic review and meta-analysis.

Authors:  Mirjam Cl Peek; Petros Charalampoudis; Bauke Anninga; Rose Baker; Michael Douek
Journal:  Future Oncol       Date:  2016-08-31       Impact factor: 3.404

4.  Lymphatic Mapping and Sentinel Lymph Node Biopsy for Breast Cancer.

Authors:  Alexandra S Heerdt
Journal:  JAMA Oncol       Date:  2018-03-01       Impact factor: 31.777

Review 5.  Incidence of unilateral arm lymphoedema after breast cancer: a systematic review and meta-analysis.

Authors:  Tracey DiSipio; Sheree Rye; Beth Newman; Sandi Hayes
Journal:  Lancet Oncol       Date:  2013-03-27       Impact factor: 41.316

6.  Surgical technical details improving sentinel node identification in breast cancer.

Authors:  J Rodier; J Janser
Journal:  Oncol Rep       Date:  1997 Mar-Apr       Impact factor: 3.906

7.  Sentinel node detection in breast cancer using contrast-enhanced sonography with 25% albumin--Initial clinical experience.

Authors:  Kiyoka Omoto; Yasuo Hozumi; Yawara Omoto; Nobuyuki Taniguchi; Kouichi Itoh; Yasutomo Fujii; Hirobumi Mizunuma; Hideo Nagai
Journal:  J Clin Ultrasound       Date:  2006-09       Impact factor: 0.910

8.  Surgical complications associated with sentinel lymph node dissection (SLND) plus axillary lymph node dissection compared with SLND alone in the American College of Surgeons Oncology Group Trial Z0011.

Authors:  Anthony Lucci; Linda Mackie McCall; Peter D Beitsch; Patrick W Whitworth; Douglas S Reintgen; Peter W Blumencranz; A Marilyn Leitch; Sukumal Saha; Kelly K Hunt; Armando E Giuliano
Journal:  J Clin Oncol       Date:  2007-05-07       Impact factor: 44.544

9.  Technical outcomes of sentinel-lymph-node resection and conventional axillary-lymph-node dissection in patients with clinically node-negative breast cancer: results from the NSABP B-32 randomised phase III trial.

Authors:  David N Krag; Stewart J Anderson; Thomas B Julian; Ann M Brown; Seth P Harlow; Takamaru Ashikaga; Donald L Weaver; Barbara J Miller; Lynne M Jalovec; Thomas G Frazier; R Dirk Noyes; André Robidoux; Hugh M C Scarth; Denise M Mammolito; David R McCready; Eleftherios P Mamounas; Joseph P Costantino; Norman Wolmark
Journal:  Lancet Oncol       Date:  2007-10       Impact factor: 41.316

10.  Sentinel lymph nodes in a swine model with melanoma: contrast-enhanced lymphatic US.

Authors:  Barry B Goldberg; Daniel A Merton; Ji-Bin Liu; Mathew Thakur; George F Murphy; Larry Needleman; Audun Tornes; Flemming Forsberg
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

View more
  1 in total

1.  Contrast-enhanced lymphatic US can improve the preoperative diagnostic performance for sentinel lymph nodes in early breast cancer.

Authors:  Zihan Niu; Yuanjing Gao; Mengsu Xiao; Feng Mao; Yidong Zhou; Qingli Zhu; Yuxin Jiang
Journal:  Eur Radiol       Date:  2022-09-24       Impact factor: 7.034

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.