Accuracy of a Low-Cost Continuous Subcutaneous Insulin Infusion Pump Prototype: In Vitro Study Using Combined Methodologies.

Fernanda Silva Tenorio1, Luiz Eduardo Galvão Martins2, Tatiana Sousa Cunha2.   

Abstract

Considering that infusion devices are safety-critical systems, the main goal of this paper is to evaluate the infusion accuracy and precision of a low-cost insulin infusion pump prototype, using two different methodologies. The first one used a microgravimetric method adapted from IEC60601-2-24, and the second estimated the displacement of the syringe plunger in response to programmed infusions. The low-cost prototype resulted in a compact and functional device with good accuracy. The prototype infused the programmed fluid doses with an average error of 2.2%. The percentage of infusions within ± 5% accuracy was 42.50 and of 84.17% for the ± 15% limit. The developed miniaturized mechanical system presented functionality, precision, and accuracy when coupled to the electronic system, responded well to repeatability tests. Additionally, the results from in vitro tests demonstrated that the performance of the device is satisfactory and comparable to commercial continuous insulin infusion pumps. This study presents a low-cost prototype as a candidate to be used by type 1 diabetic patients in Brazil and developing countries, especially in the context of public health.
© 2021. Biomedical Engineering Society.

Entities:  

Keywords:  Accuracy; Diabetes mellitus type 1; Insulin infusion pump; Mechanical system; Quantitative evaluation

Mesh:

Year:  2021        PMID: 33495976     DOI: 10.1007/s10439-020-02721-8

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  2 in total

1.  Cost-effectiveness of insulin pumps compared with multiple daily injections both provided with structured education for adults with type 1 diabetes: a health economic analysis of the Relative Effectiveness of Pumps over Structured Education (REPOSE) randomised controlled trial.

Authors:  Daniel John Pollard; Alan Brennan; Simon Dixon; Norman Waugh; Jackie Elliott; Simon Heller; Ellen Lee; Michael Campbell; Hasan Basarir; David White
Journal:  BMJ Open       Date:  2018-04-07       Impact factor: 2.692

2.  Impact of the Type of Continuous Insulin Administration on Metabolism in a Diabetic Rat Model.

Authors:  A Schaschkow; C Mura; S Dal; A Langlois; E Seyfritz; C Sookhareea; W Bietiger; C Peronet; N Jeandidier; M Pinget; S Sigrist; E Maillard
Journal:  J Diabetes Res       Date:  2016-07-18       Impact factor: 4.011

  2 in total
  1 in total

Review 1.  The Relationship Between Different Bench Test Methodologies and Accuracy of Insulin Infusion Pumps: A Systematic Literature Review.

Authors:  Fernanda Silva Tenorio; Luiz Eduardo Galvão Martins; Glória Sthefany Pereira da Silva; Camila Bertini Martins; Ana Lucia Domingues Neves; Tatiana Sousa Cunha
Journal:  Ann Biomed Eng       Date:  2022-08-11       Impact factor: 4.219

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.