Literature DB >> 33479835

Acetabular screws do not improve early revision rates in primary total hip arthroplasty. An instrumented registry analysis.

Mary Nugent1, David G Campbell2, Peter L Lewis3, Alana R Cuthbert3, Lucien B Solomon4.   

Abstract

BACKGROUND: Initial stability of uncemented acetabular components in total hip arthroplasty (THA) is important for osseointegration and potentially enhanced by screw fixation. We used Australian Orthopaedic Association National Joint Replacement Registry data to determine whether screw usage influences uncemented acetabular component survival.
METHODS: Primary THA with uncemented acetabular components performed for osteoarthritis from 1999 to 2018 was included. Survivorship was calculated using Kaplan-Meier estimates of cumulative percent revision (CPR). Comparisons used Cox proportional hazards method. An instrumental variable analysis adjusted for surgeon preference for screws as a confounding factor was used.
RESULTS: Three hundred thirty thousand one hundred ninety-two THAs were included (31.8% with screws, 68.2% without). Two hundred twenty thousand six hundred seven were included in the instrumental variable analysis. Revision rate of acetabular components (all causes) was higher with screws during the first six years (hazard ratio (HR) = 1.45 (95% CI 1.34, 1.57), p < 0.001) and lower thereafter (HR = 0.81 (95% CI 0.67, 0.98), p = 0.027). Revision rate of acetabular components for loosening was higher with screws over the entire study period (HR = 1.73 (95% CI 1.51, 1.98), p < 0.001). Overall THA revision rate was higher with screws during the first six years (HR = 1.20 (95% CI 1.15, 1.26), p < 0.001) but lower thereafter (HR = 0.89 (95% CI 0.81, 0.98), p = 0.020). Revision rate for dislocation was higher with screws over the entire period (HR = 1.16 (95% CI 1.06, 1.26), p < 0.001). Instrumental variable analysis revealed higher revision rates with acetabular screws in the first six years. (HR = 1.18 (95% CI 1.09-1.29), p < 0.001).
CONCLUSION: Screws did not confer a protective effect against acetabular loosening and were not associated with long-term negative consequences.

Entities:  

Keywords:  Acetabulum; Arthroplasty; Hip; Revision; Uncemented

Year:  2021        PMID: 33479835     DOI: 10.1007/s00264-021-04949-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  12 in total

1.  The number of screws, bone quality, and friction coefficient affect acetabular cup stability.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Heng-Li Huang; Mark E Zobitz; Weng-Pin Chen; Kuo-An Lai; Kai-Nan An
Journal:  Med Eng Phys       Date:  2006-12-27       Impact factor: 2.242

2.  Press-fit cementless acetabular fixation with and without screws.

Authors:  Sheng-Hui Ni; Lei Guo; Tian-Long Jiang; Jie Zhao; Yan-Gang Zhao
Journal:  Int Orthop       Date:  2013-08-28       Impact factor: 3.075

3.  Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

Authors:  Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Nao Shibanuma; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2014-01-11       Impact factor: 3.075

4.  Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening.

Authors:  Luis Natera; Marius Valera; Esther Moya Gómez; Natalia Ibañez; Xavier Crusi; Rogelio Sancho
Journal:  Hip Int       Date:  2017-01-28       Impact factor: 2.135

5.  Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

Authors:  Tomonori Tabata; Nobuhiro Kaku; Katsutoshi Hara; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-25

6.  Uncemented cups with and without screw holes in primary THA: a Swedish Hip Arthroplasty Register study with 22,725 hips.

Authors:  Volker Otten; Sebastian Mukka; Kjell Nilsson; Sead Crnalic; Johan Kärrholm
Journal:  Acta Orthop       Date:  2019-04-08       Impact factor: 3.717

7.  Cup Alignment Change after Screw Fixation in Total Hip Arthroplasty.

Authors:  Yingyong Suksathien; Urawit Piyapromdee; Thanut Tippimanchai
Journal:  Indian J Orthop       Date:  2019 Sep-Oct       Impact factor: 1.251

8.  Relationship between use of screws and acetabular cup stability in total hip arthroplasty: a meta-analysis.

Authors:  Chen Fei; Peng-Fei Wang; Wei Wei; Shuang-Wei Qu; Kun Yang; Zhi Li; Yan Zhuang; Bin-Fei Zhang; Kun Zhang
Journal:  J Int Med Res       Date:  2020-02       Impact factor: 1.671

9.  No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome.

Authors:  Michiel J M Minten; Petra J C Heesterbeek; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-06-14       Impact factor: 3.717

10.  Comparing Long-term Mortality After Carotid Endarterectomy vs Carotid Stenting Using a Novel Instrumental Variable Method for Risk Adjustment in Observational Time-to-Event Data.

Authors:  Jesse A Columbo; Pablo Martinez-Camblor; Todd A MacKenzie; Douglas O Staiger; Ravinder Kang; Philip P Goodney; A James O'Malley
Journal:  JAMA Netw Open       Date:  2018-09-07
View more
  3 in total

1.  Comment to "Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up".

Authors:  Zhi-Qiang Fan; Xin Xu
Journal:  Int Orthop       Date:  2021-03-16       Impact factor: 3.075

Review 2.  Efficacy and Safety of Acetabular Cup without Screw Fixation in Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Takanori Miura; Hiroaki Kijima; Ryota Kimura; Jun Watanabe; Yuji Okazaki; Naohisa Miyakoshi
Journal:  Medicina (Kaunas)       Date:  2022-08-05       Impact factor: 2.948

3.  The use of acetabular screws in total hip arthroplasty and its influence on wear and periacetabular osteolysis in the long-term follow-up.

Authors:  Steffen Brodt; Kathleen Bischoff; Marcel Schulze; Dimitri Nowack; Andreas Roth; Georg Matziolis
Journal:  Int Orthop       Date:  2021-09-28       Impact factor: 3.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.