Literature DB >> 33478426

Phaco-UCP; combined phacoemulsification and ultrasound ciliary plasty versus phacoemulsification alone for management of coexisting cataract and open angle glaucoma: a randomized clinical trial.

Magda A Torky1, Yousef A Alzafiri2, Ameera G Abdelhameed3, Eman A Awad1.   

Abstract

BACKGROUND: Various surgical techniques have been described, to be combined with cataract surgery in glaucoma patients, aiming for an additional reduction of intraocular pressure (IOP), hence minimizing the burden of anti-glaucoma medication (AGM). Ultrasound ciliary plasty (UCP) is a recent microinvasive glaucoma surgery (MIGS) recommended for primary and refractory glaucoma. This study was conducted to evaluate the safety and efficacy of a new technique; combined phacoemulsification and ultrasound ciliary plasty (Phaco-UCP) as a primary surgical treatment for coexisting cataract and open angle glaucoma.
METHODS: A randomized clinical trial, including 61 eyes of 61 patients with visually significant cataract and open angle glaucoma, randomized to either Phaco-UCP (study group; 31 eyes) or phacoemulsification alone (Phaco-alone) (control group; 30 eyes). Primary outcomes included reduction in IOP and/or the number of AGM. Secondary outcomes included visual acuity improvement and complications. Qualified Success was defined as an IOP reduction ≥ 20% from baseline value, with an IOP 6-21 mmHg, with no additional AGM or glaucoma surgery. Failure was defined as either < 20% IOP reduction, despite AGM use, the need of glaucoma surgeries or serious complications.
RESULTS: At 18 months postoperatively, Phaco-UCP group had a median IOP reduction of 7 mmHg (Q1, Q3 = 3, 10) compared to 2 mmHg (Q1, Q3 = 2, 3) in Phaco-alone group (P < 0.001). Phaco-UCP group had significantly higher success rate at all time points reaching 67.7% at the last follow-up versus 16.7% only in Phaco-alone group (P< 0.001). The median number of AGM significantly decreased from [3 (Q1, Q3 = 2, 4), 3 (Q1, Q3 = 2,3)] respectively, (P =0.3)] at baseline to [1 (Q1,Q3 = 1, 2), 2 (Q1,Q3 = 2, 2)] respectively, (P < 0.001)] at 18 months postoperatively. No serious intraoperative or postoperative complications were encountered in either group.
CONCLUSION: Phaco-UCP is a simple, safe and effective procedure for management of coexisting cataract and open angle glaucoma. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT04430647 ; retrospectively registered. June 12, 2020.

Entities:  

Keywords:  OAG; Phaco-UCP; Phacoemulsification; Ultrasound ciliary plasty

Mesh:

Year:  2021        PMID: 33478426      PMCID: PMC7819220          DOI: 10.1186/s12886-021-01818-5

Source DB:  PubMed          Journal:  BMC Ophthalmol        ISSN: 1471-2415            Impact factor:   2.209


  31 in total

Review 1.  Surgical strategies in patients with combined cataract and glaucoma.

Authors:  C Vass; R Menapace
Journal:  Curr Opin Ophthalmol       Date:  2004-02       Impact factor: 3.761

2.  Long-term reduction of laser flare values after trabeculectomy but not after cyclodestructive procedures in uveitis patients.

Authors:  Carsten Heinz; Beatrix Zurek-Imhoff; Jörg Koch; Martin Rösel; Arnd Heiligenhaus
Journal:  Int Ophthalmol       Date:  2011-03-25       Impact factor: 2.031

3.  Short- and long-term effects on the ciliary body and the aqueous outflow pathways of high-intensity focused ultrasound cyclocoagulation.

Authors:  Florent Aptel; Aurélie Béglé; Arash Razavi; Fabrice Romano; Thomas Charrel; Jean-Yves Chapelon; Philippe Denis; Cyril Lafon
Journal:  Ultrasound Med Biol       Date:  2014-07-02       Impact factor: 2.998

4.  Ocular biometric parameters associated with intraocular pressure reduction after cataract surgery in normal eyes.

Authors:  Hyun Seung Yang; Junsung Lee; Sangkyung Choi
Journal:  Am J Ophthalmol       Date:  2013-04-28       Impact factor: 5.258

5.  Endoscopic cyclophotocoagulation for the treatment of glaucoma: an Asian experience.

Authors:  Leonard W Yip; Shao O Yong; Arul Earnest; Jian Ji; Boon A Lim
Journal:  Clin Exp Ophthalmol       Date:  2009-09       Impact factor: 4.207

6.  Ultrasound Cyclo-Plasty in Patients with Glaucoma: 1-Year Results from a Multicentre Prospective Study.

Authors:  Giuseppe Giannaccare; Aldo Vagge; Stefano Sebastiani; Lara E Urbini; Paolo Corazza; Marco Pellegrini; Luciana Carmassi; Fulvio Bergamini; Carlo E Traverso; Emilio C Campos
Journal:  Ophthalmic Res       Date:  2018-05-16       Impact factor: 2.892

7.  Outcomes of combined phacoemulsification and deep sclerectomy: a 10-year UK single-centre study.

Authors:  K Mercieca; B Shevade; N Anand
Journal:  Eye (Lond)       Date:  2015-09-04       Impact factor: 3.775

8.  Clinical application of the lens opacities classification system III in the performance of phacoemulsification.

Authors:  James A Davison; Leo T Chylack
Journal:  J Cataract Refract Surg       Date:  2003-01       Impact factor: 3.351

9.  Safety and efficacy of high-intensity focused ultrasound in severe or refractory glaucoma.

Authors:  Juliette Hugo; Frederic Matonti; Marie Beylerian; Emilie Zanin; Florent Aptel; Danièle Denis
Journal:  Eur J Ophthalmol       Date:  2019-09-25       Impact factor: 2.597

10.  Pupil Ovalization and Accommodation Loss after High-intensity Focused Ultrasound Treatment for Glaucoma: A Case Report.

Authors:  Amado Rivero-Santana; David Pérez-Silguero; Miguel A Pérez-Silguero; Pablo Encinas-Pisa
Journal:  J Curr Glaucoma Pract       Date:  2019 May-Aug
View more
  1 in total

1.  Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Authors:  Di Chen; Xiu-Juan Guo; Shu-Ke Luo; Yan Lu; Xiu-Rong Tang
Journal:  BMC Ophthalmol       Date:  2022-10-07       Impact factor: 2.086

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.