Literature DB >> 3347752

Pneumothorax and other lung diseases: effect of altered resolution and edge enhancement on diagnosis with digitized radiographs.

L R Goodman1, W D Foley, C R Wilson, R S Tikofsky, R G Hoffmann.   

Abstract

Prior studies have shown that pneumothorax is one of the more difficult entities to diagnose with digitized radiography. This study was designed to test whether increasing resolution from 1.25 to 2.5 line pairs per millimeter (lp/mm) and image processing (edge enhancement from unsharp masking) would increase accuracy and confidence in the diagnosis of pneumothorax, as well as normal cases and other forms of lung disease. Conventional radiographs were digitized with use of a laser reader and then reformatted as film hard copy. Eleven observers read 35 cases reformatted in three different ways (1.25 lp/mm, 2.5 lp/mm, 1.25 lp/mm unsharp mask). The images with finer resolution (2.5 lp/mm) and unsharp mask images were superior to those with coarser resolution (1.25 lp/mm) for the diagnosis of pneumothorax. There was no difference in diagnostic accuracy for normal patients. For abnormalities other than pneumothorax, the unsharp mask images were significantly worse. Confidence in the diagnosis of pneumothorax and other abnormalities was highest with the finest resolution (2.5 lp/mm).

Entities:  

Mesh:

Year:  1988        PMID: 3347752     DOI: 10.1148/radiology.167.1.3347752

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Enhancement of chest images by automatic adaptive spatial filtering.

Authors:  M Souto; J Correa; P G Tahoces; D Tucker; K S Malagari; J J Vidal; R G Fraser
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 2.  Literature review: picture archiving and communication system.

Authors:  U P Schmiedl; A H Rowberg
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

Review 3.  Chest imaging within the radiology department by means of photostimulable phosphor computed radiography: a review.

Authors:  H Blume; R G Jost
Journal:  J Digit Imaging       Date:  1992-05       Impact factor: 4.056

4.  Unsharp masking of low-dosed digital luminescence radiographs: results of a receiver operating characteristics analysis.

Authors:  R D Müller; M Voss; H Hirche; B Buddenbrock; V John; E Bosch
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

5.  Detection of interstitial lung abnormalities on picture archive and communication system video monitors.

Authors:  T L Washowich; S C Williams; L A Richardson; G E Simmons; N V Dao; T W Allen; G C Hammet; M J Morris
Journal:  J Digit Imaging       Date:  1997-02       Impact factor: 4.056

6.  Context-dependent enhancements for radiological images.

Authors:  B Plessis; M Goldberg; R Dillon; J Tombaugh; J Robertson; G Bélanger; N Hickey
Journal:  J Digit Imaging       Date:  1989-05       Impact factor: 4.056

7.  Image optimization in a computed-radiography/photostimulable-phosphor system.

Authors:  R H Sherrier; H G Chotas; G A Johnson; C Chiles; C E Ravin
Journal:  J Digit Imaging       Date:  1989-11       Impact factor: 4.056

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.