| Literature DB >> 33463422 |
Ceyhun Çağlar1, Serhat Akçaalan, Halil İbrahim Özaslan, Hilal Yağar, Mahmut Uğurlu.
Abstract
OBJECTIVES: This study aims to compare clinically and functionally patients who had previously undergone tension band wiring (TBW) or plate fixation (PF) procedure due to the diagnosis of Mayo type 2A olecranon fracture in our clinic. PATIENTS AND METHODS: Data of 92 patients (51 males, 41 females; mean age 42.3±12.6 years; range, 16 to 75 years) operated on for olecranon fractures between January 2014 and December 2018 were recorded retrospectively. Forty-four patients received TBW and 48 patients received PF treatment. Their Disabilities of the Arm, Shoulder, and Hand (DASH) and Mayo scores and elbow range of motion (ROM) measurements were used for clinical and functional evaluations. Data including the time to return to work, revision rate, and follow-up time were also recorded.Entities:
Mesh:
Year: 2021 PMID: 33463422 PMCID: PMC8073451 DOI: 10.5606/ehc.2021.75812
Source DB: PubMed Journal: Jt Dis Relat Surg ISSN: 2687-4792
Characteristic features of patients in both groups
| TBW group | PF group | ||||||
| n | % | Mean±SD | n | % | Mean±SD | ||
| Age (year) | 40.4±18.1 | 43.7±20.5 | 0.726 | ||||
| Sex | 0.458 | ||||||
| Male | 24 | 55 | 27 | 56 | |||
| Female | 20 | 45 | 21 | 44 | |||
| Follow-up (month) | 39.3±16.8 | 37.2±17.6 | 0.623 | ||||
| Revisions (patient) (ratio) | 6 | 14 | 1 | 2 | 0.335 | ||
| Return to work (week) | 9.2±3.1 | 7.8±2.6 | 0.279 | ||||
| TBW: Tension band wiring; PF: Plate fixation; SD Standard deviation. | |||||||
Values of range and loss of motion
| TBW group | PF group | ||
| Degree±SD | Degree±SD | ||
| Mean extension deficit | 5.3±2.1 | 2.8±1.8 | 0.385 |
| Mean flexion deficit | 5.0±2.2 | 3.5±1.9 | 0.426 |
| Mean pronation deficit | 0.6±0.2 | 0.3±0.2 | 0.752 |
| Mean supination deficit | 1.2±0.5 | 0.9±0.4 | 0.811 |
| Mean flexion-extension ROM | 139.8±7.3 | 143.8±5.8 | 0.043* |
| Mean pronation-supination ROM | 98.3±1.2 | 98.8±0.8 | 0.257 |
| TBW: Tension band wiring; PF: Plate fixation; SD: Standard deviation; ROM: Range of motion; * Statistically significant. | |||
Values of Disabilities of the Arm, Shoulder, and Hand and Mayo score
| TBW group | PF group | ||
| Mean±SD | Mean±SD | ||
| DASH score | 10.0±1.8 | 7.7±1.2 | 0.001* |
| Mayo score | 84.0±9.3 | 88.3±9.1 | 0.049* |
| TBW: Tension band wiring; PF: Plate fixation; SD: Standard deviation; DASH: Disabilities of the Arm, Shoulder, and Hand; * Statistically significant. | |||