Literature DB >> 33460372

Fully Automated 3-D Ultrasound Segmentation of the Placenta, Amniotic Fluid, and Fetus for Early Pregnancy Assessment.

Padraig Looney, Yi Yin, Sally L Collins, Kypros H Nicolaides, Walter Plasencia, Malid Molloholli, Stavros Natsis, Gordon N Stevenson.   

Abstract

Volumetric placental measurement using 3-D ultrasound has proven clinical utility in predicting adverse pregnancy outcomes. However, this metric cannot currently be employed as part of a screening test due to a lack of robust and real-time segmentation tools. We present a multiclass (MC) convolutional neural network (CNN) developed to segment the placenta, amniotic fluid, and fetus. The ground-truth data set consisted of 2093 labeled placental volumes augmented by 300 volumes with placenta, amniotic fluid, and fetus annotated. A two-pathway, hybrid (HB) model using transfer learning, a modified loss function, and exponential average weighting was developed and demonstrated the best performance for placental segmentation (PS), achieving a Dice similarity coefficient (DSC) of 0.84- and 0.38-mm average Hausdorff distances (HDAV). The use of a dual-pathway architecture improved the PS by 0.03 DSC and reduced HDAV by 0.27 mm compared with a naïve MC model. The incorporation of exponential weighting produced a further small improvement in DSC by 0.01 and a reduction of HDAV by 0.44 mm. Per volume inference using the FCNN took 7-8 s. This method should enable clinically relevant morphometric measurements (such as volume and total surface area) to be automatically generated for the placenta, amniotic fluid, and fetus. The ready availability of such metrics makes a population-based screening test for adverse pregnancy outcomes possible.

Entities:  

Mesh:

Year:  2021        PMID: 33460372      PMCID: PMC8154733          DOI: 10.1109/TUFFC.2021.3052143

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  26 in total

Review 1.  Latest advances in understanding preeclampsia.

Authors:  Christopher W Redman; Ian L Sargent
Journal:  Science       Date:  2005-06-10       Impact factor: 47.728

Review 2.  Aetiology and pathogenesis of IUGR.

Authors:  Srividhya Sankaran; Phillipa M Kyle
Journal:  Best Pract Res Clin Obstet Gynaecol       Date:  2009-08-08       Impact factor: 5.237

Review 3.  Recent advances in ultrasound technology.

Authors:  Robert T O'Brien; Shannon P Holmes
Journal:  Clin Tech Small Anim Pract       Date:  2007-08

Review 4.  A survey on deep learning in medical image analysis.

Authors:  Geert Litjens; Thijs Kooi; Babak Ehteshami Bejnordi; Arnaud Arindra Adiyoso Setio; Francesco Ciompi; Mohsen Ghafoorian; Jeroen A W M van der Laak; Bram van Ginneken; Clara I Sánchez
Journal:  Med Image Anal       Date:  2017-07-26       Impact factor: 8.545

5.  User-Guided Segmentation of Multi-modality Medical Imaging Datasets with ITK-SNAP.

Authors:  Paul A Yushkevich; Artem Pashchinskiy; Ipek Oguz; Suyash Mohan; J Eric Schmitt; Joel M Stein; Dženan Zukić; Jared Vicory; Matthew McCormick; Natalie Yushkevich; Nadav Schwartz; Yang Gao; Guido Gerig
Journal:  Neuroinformatics       Date:  2019-01

6.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

7.  Evaluating the intra- and interobserver reliability of three-dimensional ultrasound and power Doppler angiography (3D-PDA) for assessment of placental volume and vascularity in the second trimester of pregnancy.

Authors:  Nia W Jones; Nick J Raine-Fenning; Hatem A Mousa; Eileen Bradley; George J Bugg
Journal:  Ultrasound Med Biol       Date:  2011-01-21       Impact factor: 2.998

8.  Slic-Seg: A minimally interactive segmentation of the placenta from sparse and motion-corrupted fetal MRI in multiple views.

Authors:  Guotai Wang; Maria A Zuluaga; Rosalind Pratt; Michael Aertsen; Tom Doel; Maria Klusmann; Anna L David; Jan Deprest; Tom Vercauteren; Sébastien Ourselin
Journal:  Med Image Anal       Date:  2016-05-03       Impact factor: 8.545

9.  3D fractional moving blood volume (3D-FMBV) demonstrates decreased first trimester placental vascularity in pre-eclampsia but not the term, small for gestation age baby.

Authors:  Sally L Collins; Alec W Welsh; Lawrence Impey; J Alison Noble; Gordon N Stevenson
Journal:  PLoS One       Date:  2017-06-01       Impact factor: 3.240

10.  Reproducibility of 3-Dimensional Ultrasound Measurements of Placental Volume at Gestational Ages 11 - 14 Weeks.

Authors:  M L Larsen; K V Naver; M M Kjaer; F S Jorgensen; L Nilas
Journal:  Facts Views Vis Obgyn       Date:  2015-12-28
View more
  2 in total

Review 1.  Amniotic Fluid Classification and Artificial Intelligence: Challenges and Opportunities.

Authors:  Irfan Ullah Khan; Nida Aslam; Fatima M Anis; Samiha Mirza; Alanoud AlOwayed; Reef M Aljuaid; Razan M Bakr
Journal:  Sensors (Basel)       Date:  2022-06-17       Impact factor: 3.847

2.  Toward deep observation: A systematic survey on artificial intelligence techniques to monitor fetus via ultrasound images.

Authors:  Mahmood Alzubaidi; Marco Agus; Khalid Alyafei; Khaled A Althelaya; Uzair Shah; Alaa Abd-Alrazaq; Mohammed Anbar; Michel Makhlouf; Mowafa Househ
Journal:  iScience       Date:  2022-07-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.