Literature DB >> 3345277

Anterior fontanelle pressure responses to tracheal intubation in the awake and anaesthetized infant.

P J Stow1, M E McLeod, F A Burrows, R E Creighton.   

Abstract

In order to define the changes in intracranial pressure which occur during tracheal intubation in young infants, a Ladd transducer was used to monitor anterior fontanelle pressure (AFP) non-invasively in awake (group 1, n = 14) and anaesthetized (group 2, n = 10) infants during intubation of the trachea. Heart rate and systolic arterial pressure were also recorded. In quiet, undisturbed infants, AFP (mean +/- SEM) was similar in groups 1 (9.6 +/- 0.5 mm Hg) and 2 (8.7 +/- 0.8 mm Hg); with crying, AFP increased significantly in both groups. During laryngoscopy in group 1, AFP increased to 33.5 +/- 3.6 mm Hg, which was significantly greater than in the quiet infant, but did not differ significantly from measurements in the crying infant. In group 2, AFP increased significantly to 15.8 +/- 18 mm Hg during laryngoscopy. This increase was significantly less than the group 1 response. Neither heart rate nor systolic arterial pressure changed significantly in either group during laryngoscopy--when compared with measurements in the quiet state. It was concluded that AFP increases significantly during intubation and during crying in the infant. The response to intubation is only partially attenuated by the prior administration of general anaesthesia.

Entities:  

Mesh:

Year:  1988        PMID: 3345277     DOI: 10.1093/bja/60.2.167

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  11 in total

1.  Premedication before intubation in UK neonatal units.

Authors:  S Whyte; G Birrell; J Wyllie
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-01       Impact factor: 5.747

2.  Changes in resuscitation practice at birth.

Authors:  A C L Allwood; R J Madar; J H Baumer; L Readdy; D Wright
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2003-09       Impact factor: 5.747

Review 3.  Should premedication be used for semi-urgent or elective intubation in neonates?

Authors:  E Byrne; R MacKinnon
Journal:  Arch Dis Child       Date:  2006-01       Impact factor: 3.791

4.  Impact of premedication on neonatal intubations by pediatric and neonatal trainees.

Authors:  C N Le; D M Garey; T A Leone; J K Goodmar; W Rich; N N Finer
Journal:  J Perinatol       Date:  2014-02-27       Impact factor: 2.521

5.  Cyclic Head Rotations Produce Modest Brain Injury in Infant Piglets.

Authors:  Brittany Coats; Gil Binenbaum; Colin Smith; Robert L Peiffer; Cindy W Christian; Ann-Christine Duhaime; Susan S Margulies
Journal:  J Neurotrauma       Date:  2016-05-11       Impact factor: 5.269

6.  Awake intubation increases intracranial pressure without affecting cerebral blood flow velocity in infants.

Authors:  C Millar; B Bissonnette
Journal:  Can J Anaesth       Date:  1994-04       Impact factor: 5.063

Review 7.  Stimulating and maintaining spontaneous breathing during transition of preterm infants.

Authors:  Janneke Dekker; Anton H van Kaam; Charles C Roehr; Andreas W Flemmer; Elizabeth E Foglia; Stuart B Hooper; Arjan B Te Pas
Journal:  Pediatr Res       Date:  2019-06-19       Impact factor: 3.756

8.  Quality assessment and response to less invasive surfactant administration (LISA) without sedation.

Authors:  Ellen de Kort; Suzanne Kusters; Hendrik Niemarkt; Carola van Pul; Irwin Reiss; Sinno Simons; Peter Andriessen
Journal:  Pediatr Res       Date:  2019-08-27       Impact factor: 3.756

9.  Premedication for neonatal intubation: Current practice in Saudi Arabia.

Authors:  Rafat Mosalli; Lana Shaiba; Khalid Alfaleh; Bosco Paes
Journal:  Saudi J Anaesth       Date:  2012 Oct-Dec

10.  A comparison of surfactant administration through i-gel and ET-tube in the treatment of respiratory distress syndrome in newborns weighing more than 2000 grams.

Authors:  Alireza Sadeghnia; Mozhgan Tanhaei; Majid Mohammadizadeh; Mohammad Nemati
Journal:  Adv Biomed Res       Date:  2014-07-31
View more