Literature DB >> 33441675

Wrist-wearable bioelectrical impedance analyzer with miniature electrodes for daily obesity management.

Myoung Hoon Jung1, Kak Namkoong2, Yeolho Lee1, Young Jun Koh3, Kunsun Eom1, Hyeongseok Jang1, Wonjong Jung1, Jungmok Bae4, Jongae Park1.   

Abstract

Bioelectrical impedance analysis (BIA) is used to analyze human body composition by applying a small alternating current through the body and measuring the impedance. The smaller the electrode of a BIA device, the larger the impedance measurement error due to the contact resistance between the electrode and human skin. Therefore, most commercial BIA devices utilize electrodes that are large enough (i.e., 4 × 1400 mm2) to counteract the contact resistance effect. We propose a novel method of compensating for contact resistance by performing 4-point and 2-point measurements alternately such that body impedance can be accurately estimated even with considerably smaller electrodes (outer electrodes: 68 mm2; inner electrodes: 128 mm2). Additionally, we report the use of a wrist-wearable BIA device with single-finger contact measurement and clinical test results from 203 participants at Seoul St. Mary's Hospital. The correlation coefficient and standard error of estimate of percentage body fat were 0.899 and 3.76%, respectively, in comparison with dual-energy X-ray absorptiometry. This result exceeds the performance level of the commercial upper-body portable body fat analyzer (Omron HBF-306). With a measurement time of 7 s, this sensor technology is expected to provide a new possibility of a wearable bioelectrical impedance analyzer, toward obesity management.

Entities:  

Year:  2021        PMID: 33441675      PMCID: PMC7806851          DOI: 10.1038/s41598-020-79667-3

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  12 in total

1.  [Bioelectric properties of tissue. Impedance measurement in clinical medicine. Significance of curves obtained].

Authors:  M A THOMASSET
Journal:  Lyon Med       Date:  1962-07-15

Review 2.  Bioelectrical impedance analysis--part I: review of principles and methods.

Authors:  Ursula G Kyle; Ingvar Bosaeus; Antonio D De Lorenzo; Paul Deurenberg; Marinos Elia; José Manuel Gómez; Berit Lilienthal Heitmann; Luisa Kent-Smith; Jean-Claude Melchior; Matthias Pirlich; Hermann Scharfetter; Annemie M W J Schols; Claude Pichard
Journal:  Clin Nutr       Date:  2004-10       Impact factor: 7.324

3.  Evaluation of body fat estimated from body mass index, skinfolds and impedance. A comparative study.

Authors:  B L Heitmann
Journal:  Eur J Clin Nutr       Date:  1990-11       Impact factor: 4.016

4.  Bioelectrical impedance analysis-part II: utilization in clinical practice.

Authors:  Ursula G Kyle; Ingvar Bosaeus; Antonio D De Lorenzo; Paul Deurenberg; Marinos Elia; José Manuel Gómez; Berit Lilienthal Heitmann; Luisa Kent-Smith; Jean-Claude Melchior; Matthias Pirlich; Hermann Scharfetter; Annemie M W J Schols; Claude Pichard
Journal:  Clin Nutr       Date:  2004-12       Impact factor: 7.324

Review 5.  Bioelectrical impedance analysis: a review of principles and applications.

Authors:  R F Kushner
Journal:  J Am Coll Nutr       Date:  1992-04       Impact factor: 3.169

6.  Regional and total body bioelectrical impedance analysis compared with DXA in Icelandic elderly.

Authors:  A Ramel; O G Geirsdottir; A Arnarson; I Thorsdottir
Journal:  Eur J Clin Nutr       Date:  2011-05-11       Impact factor: 4.016

7.  Correlation of whole-body impedance with total body water volume.

Authors:  E C Hoffer; C K Meador; D C Simpson
Journal:  J Appl Physiol       Date:  1969-10       Impact factor: 3.531

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Single prediction equation for bioelectrical impedance analysis in adults aged 20--94 years.

Authors:  U G Kyle; L Genton; L Karsegard; D O Slosman; C Pichard
Journal:  Nutrition       Date:  2001-03       Impact factor: 4.008

10.  Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System.

Authors:  Vega Pradana Rachim; Wan-Young Chung
Journal:  Sci Rep       Date:  2019-05-28       Impact factor: 4.379

View more
  2 in total

Review 1.  Wearables in Cardiovascular Disease.

Authors:  Sanchit Kumar; Angela M Victoria-Castro; Hannah Melchinger; Kyle D O'Connor; Mitchell Psotka; Nihar R Desai; Tariq Ahmad; F Perry Wilson
Journal:  J Cardiovasc Transl Res       Date:  2022-09-09       Impact factor: 3.216

2.  Body composition analysis in patients with acute heart failure: the Scale Heart Failure trial.

Authors:  Fiorangelo De Ieso; Markus Reinhold Mutke; Noe Karl Brasier; Christina Janitha Raichle; Bettina Keller; Celine Sucker; Khaled Abdelhamid; Tiziano Bloch; Pamela Reissenberger; Ladina Schönenberg; Sandro Kevin Fischer; Jonas Saboz; Nora Weber; Sabine Schädelin; Nicole Bruni; Patrick R Wright; Jens Eckstein
Journal:  ESC Heart Fail       Date:  2021-10-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.