Literature DB >> 33439138

Step and Distance Measurement From a Low-Cost Consumer-Based Hip and Wrist Activity Monitor: Protocol for a Validity and Reliability Assessment.

Thomas Carlin1,2, Nicolas Vuillerme1,2,3.   

Abstract

BACKGROUND: Self-tracking via wearable and mobile technologies is becoming an essential part of personal health management. At this point, however, little information is available to substantiate the validity and reliability of low-cost consumer-based hip and wrist activity monitors, with regard more specifically to the measurements of step counts and distance traveled while walking.
OBJECTIVE: The aim of our study is to assess the validity and reliability of step and distance measurement from a low-cost consumer-based hip and wrist activity monitor specific in various walking conditions that are commonly encountered in daily life. Specifically, this study is designed to evaluate whether and to what extent validity and reliability could depend on the sensor placement on the human body and the walking task being performed.
METHODS: Thirty healthy participants will be instructed to wear four PBN 2433 (Nakosite) activity monitors simultaneously, with one placed on each hip and each wrist. Participants will attend two experimental sessions separated by 1 week. During each experimental session, two separate studies will be performed. In study 1, participants will be instructed to complete a 2-minute walk test along a 30-meter indoor corridor under 3 walking speeds: very slow, slow, and usual speed. In study 2, participants will be required to complete the following 3 conditions performed at usual walking speed: walking on flat ground, upstairs, and downstairs. Activity monitor measured step count and distance values will be computed along with the actual step count (determined from video recordings) and distance (measured using a measuring tape) to determine validity and reliability for each activity monitor placement and each walking condition.
RESULTS: Participant recruitment and data collection began in January 2020. As of June 2020, we enrolled 8 participants. Dissemination of study results in peer-reviewed journals is expected in spring 2021.
CONCLUSIONS: To the best of our knowledge, this is the first study that examines the validity and reliability of step and distance measurement during walking using the PBN 2433 (Nakosite) activity monitor. Results of this study will provide beneficial information on the effects of activity monitor placement, walking speed, and walking tasks on the validity and reliability of step and distance measurement. We believe such information is of utmost importance to general consumers, clinicians, and researchers. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/21262. ©Thomas Carlin, Nicolas Vuillerme. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 13.01.2021.

Entities:  

Keywords:  activity monitor; distance; measurement; pedometer; reliability; step count; validity; walking

Year:  2021        PMID: 33439138      PMCID: PMC7840275          DOI: 10.2196/21262

Source DB:  PubMed          Journal:  JMIR Res Protoc        ISSN: 1929-0748


  82 in total

1.  The Toronto Charter for Physical Activity: A Global Call for Action.

Authors: 
Journal:  J Phys Act Health       Date:  2010-11

2.  The usefulness of activity trackers in elderly with reduced mobility: a case study.

Authors:  Jonas Lauritzen; Adolfo Muñoz; Jose Luis Sevillano; Anton Civit
Journal:  Stud Health Technol Inform       Date:  2013

3.  Pedometer accuracy during stair climbing and bench stepping exercises.

Authors:  Makoto Ayabe; Junichiro Aoki; Kojiro Ishii; Kohsaku Takayama; Hiroaki Tanaka
Journal:  J Sports Sci Med       Date:  2008-06-01       Impact factor: 2.988

4.  Validity and reliability of the Omron HJ-303 tri-axial accelerometer-based pedometer.

Authors:  Jeremy A Steeves; Brian M Tyo; Christopher P Connolly; Douglas A Gregory; Nyle A Stark; David R Bassett
Journal:  J Phys Act Health       Date:  2011-09

5.  Validity of the "Samsung Health" application to measure steps: A study with two different samsung smartphones.

Authors:  Vicente J Beltrán-Carrillo; Alejandro Jiménez-Loaisa; Miriam Alarcón-López; Jose L L Elvira
Journal:  J Sports Sci       Date:  2018-10-17       Impact factor: 3.337

6.  Calibration of ActiGraph GT3X, Actical and RT3 accelerometers in adolescents.

Authors:  Marcelo Romanzini; Edio Luiz Petroski; David Ohara; Antonio Carlos Dourado; Felipe Fossat Reichert
Journal:  Eur J Sport Sci       Date:  2012-10-18       Impact factor: 4.050

7.  Assessment of pedometer accuracy in capturing habitual types of physical activities in overweight and obese children.

Authors:  Tom J Hazell; Caitlin V L Ellery; Tamara R Cohen; Catherine A Vanstone; Celia J Rodd; Hope A Weiler
Journal:  Pediatr Res       Date:  2016-06-24       Impact factor: 3.756

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  "Stepping Up" Activity Poststroke: Ankle-Positioned Accelerometer Can Accurately Record Steps During Slow Walking.

Authors:  Tara D Klassen; Lisa A Simpson; Shannon B Lim; Dennis R Louie; Beena Parappilly; Brodie M Sakakibara; Dominik Zbogar; Janice J Eng
Journal:  Phys Ther       Date:  2015-08-06

10.  Counting Steps in Activities of Daily Living in People With a Chronic Disease Using Nine Commercially Available Fitness Trackers: Cross-Sectional Validity Study.

Authors:  Darcy Ummels; Emmylou Beekman; Kyra Theunissen; Susy Braun; Anna J Beurskens
Journal:  JMIR Mhealth Uhealth       Date:  2018-04-02       Impact factor: 4.773

View more
  1 in total

1.  Assessing and Qualifying Neighborhood Walkability for Older Adults: Construction and Initial Testing of a Multivariate Spatial Accessibility Model.

Authors:  Valkiria Amaya; Thibauld Moulaert; Luc Gwiazdzinski; Nicolas Vuillerme
Journal:  Int J Environ Res Public Health       Date:  2022-02-05       Impact factor: 3.390