Long-Term results of total Hip Arthroplasty performed using a cementless expansive Acetabular Cup and Spotorno Femoral Stem.

Engin Carkci1, Ayse Esin Polat2, Yusuf Ozturkmen3, Tolga Tuzuner4.   

Abstract

OBJECTIVE: In this study we aimed to investigate the long-term clinical and radiological results, revision rates and causes, and the rate of implant survival in total hip arthroplasty performed using CLS® expansion cup and Spotorno® cementless femoral stem.
METHODS: Clinical results of total hip arthroplasty performed on 131 hips of 114 patients in Istanbul Training and Research Hospital between 1993 and 2003 were retrospectively evaluated according to the Harris Hip Score. Revision rates were determined and implant survival rates were identified using the Kaplan-Meier estimator.
RESULTS: Of the patients, 39 were males and 75 were females. The average age of the patients at surgery was 48.7±11.3 years. Patients were followed up for a mean period of 13.9±2.4 years. The mean Harris Hip Score was 34.35±6.09 preoperatively and 88.20±7.11 at the final follow-up (p<0.001). The Kaplan-Meier survivorship estimate for the cup at 13.9 years, taking revision for any reason as the end point was 95.6% (95% CI), while the 15th and 17th year survival rates were 90% and 85%, respectively.
CONCLUSION: In total hip arthroplasty using a cementless expansive acetabular cup, a 95.6% survival rate is achieved after an average of 14 years, whereas the rate decreases to 85% after 17 years. Even if the incidence of cup breakage is reduced with proper implantation, particle disease and periacetabular osteolysis remains a problem for the long-term survival. Copyright: © Pakistan Journal of Medical Sciences.

Entities:  

Keywords:  Hip arthroplasty; Osteolysis; Spotorno; Survivorship

Year:  2021        PMID: 33437250      PMCID: PMC7794123          DOI: 10.12669/pjms.37.1.3089

Source DB:  PubMed          Journal:  Pak J Med Sci        ISSN: 1681-715X            Impact factor:   1.088


  18 in total

1.  [Non-cemented CLS Spotorno Socket and Cemented Polyethylene Socket in Revised Replacements of the Hip Joint.].

Authors:  Z Rozkydal; P Janícek; Z Smíd
Journal:  Acta Chir Orthop Traumatol Cech       Date:  1997       Impact factor: 0.531

2.  Effect of cementless acetabular cup geometry on strain distribution and press-fit stability.

Authors:  M D Ries; M Harbaugh; J Shea; R Lambert
Journal:  J Arthroplasty       Date:  1997-02       Impact factor: 4.757

3.  Outcome of a hemispherical porous-coated acetabular component with a proximally hydroxyapatite-coated anatomical femoral component: an update at 23 to 26 years’ follow-up

Authors:  E García-Rey; R Carbonell-Escobar; J Cordero-Ampuero; E García-Cimbrelo
Journal:  Bone Joint J       Date:  2019-04       Impact factor: 5.082

4.  The CLS system. Theoretical concept and results.

Authors:  L Spotorno; S Romagnoli; N Ivaldo; G Grappiolo; E Bibbiani; D J Blaha; T A Guen
Journal:  Acta Orthop Belg       Date:  1993       Impact factor: 0.500

5.  Mid-term results of total hip arthroplasty with the CementLess Spotorno (CLS) system.

Authors:  P B de Witte; R Brand; H G W Vermeer; H J L van der Heide; A F W Barnaart
Journal:  J Bone Joint Surg Am       Date:  2011-07-06       Impact factor: 5.284

6.  The 21- to 27-year results of the Harris-Galante cementless total hip arthroplasty.

Authors:  Haruo Kawamura; Hajime Mishima; Hisashi Sugaya; Tomofumi Nishino; Yukiyo Shimizu; Shumpei Miyakawa
Journal:  J Orthop Sci       Date:  2016-03-09       Impact factor: 1.601

7.  Transverse Acetabular Ligament as an Anatomical Landmark for Intraoperative Cup Anteversion in Primary Total Hip Replacement.

Authors:  Mohammed Hatem Salal
Journal:  J Coll Physicians Surg Pak       Date:  2017-10       Impact factor: 0.711

8.  Surgeon-stratified cohort analysis of 1976 cementless Zweymüller total hip arthroplasties from a single hospital with 23,255 component years of follow-up.

Authors:  Samo Roškar; Vane Antolič; Blaž Mavčič
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-09       Impact factor: 3.067

9.  Restoration of femoral offset, rotation centers, limbs length equality of Chinese total hip arthroplasty patients.

Authors:  Yu-Ping Liu; Yue-Dong Hao
Journal:  Pak J Med Sci       Date:  2014-01       Impact factor: 1.088

10.  Long term survival analysis of cementless Spotorno femoral stem in young patients.

Authors:  Murat Mert; Cenk Ermutlu; Emrah Kovalak; Ethem Ünkar; Sibel Çağlar Okur
Journal:  Acta Orthop Traumatol Turc       Date:  2018-12-21       Impact factor: 1.511

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.