Literature DB >> 33432628

A comparison of cannula insufflation device performance for emergency front of neck airway.

Caroline M Mann1, Paul A Baker1, David M Sainsbury1, Richard Taylor2.   

Abstract

BACKGROUND: Pediatric emergency front of neck airway guidelines recommend oxygenation via cannula cricothyroidotomy or tracheotomy. AIM: The primary aim was to measure test lung pressures and volumes generated by cannula insufflation devices recommended for emergency front of neck airway compared with a pressure limit of 50 cm H2 O and volume limit of 20 ml/kg. The secondary aim was to calculate pressure and volume variability. The primary end point was test lung expansion.
METHOD: Adult, child, and infant airway models, each with three degrees of upper airway obstruction, were oxygenated using six cannula insufflation devices: 3-way stopcock, Rapid-O2 , Manujet, Enk oxygen flow modulator, Ventrain, and self-inflating bags. Test lung pressures and volumes were recorded.
RESULTS: Pressures and volumes from all devices were highly variable, despite oxygen flow calibration and strict adherence to oxygen insufflation protocols. With upper airway occlusion, pressures >50 cm H2 0 were produced by Rapid-O2 and Enk oxygen flow meter in adult and infant lungs, 3-way stopcock in adult and child lungs, and Manujet in all lung sizes. Ventrain produced acceptable pressures <35 cm H2 O in all models. Test lung volumes >20 ml/kg were recorded in airway models with fully obstructed proximal airways using Rapid-O2 and Enk oxygen flow meter in infant lungs, and Manujet in all lung sizes. Rapid-O2 produced lung volumes >20 ml/kg in the infant model with partially obstructed and open upper airways. Test lung volumes >20 ml/kg were produced by the 3-way stopcock in adult, child, and infant models. Insufflation was unsuccessful with the self-inflating bag. Ventrain produced acceptable volumes <7 ml/kg in all airway models.
CONCLUSION: Rapid-O2 , Enkoxygen flow meter, Manujet, and 3-way stopcock oxygenation devices produced highly variable and excessive airway pressures and volumes in models with obstructed upper airways. Self-inflating bag insufflation was unsuccessful. Ventrain was the only device that insufflated oxygen with acceptable pressures and volumes in adult, child, and infant airway models with any degree of airway obstruction.
© 2021 John Wiley & Sons Ltd.

Entities:  

Keywords:  Tracheal; airway; cannula; oxygenation; pediatric; pressures; volumes

Mesh:

Year:  2021        PMID: 33432628     DOI: 10.1111/pan.14128

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  3 in total

1.  Near total intrathoracic airway obstruction managed with a Tritube (R) and flow-controlled ventilation: a reply.

Authors:  L Böttinger; J Uriarte; J W A van der Hoorn
Journal:  Anaesth Rep       Date:  2022-03-22

Review 2.  Ventilation through small-bore airways in children by implementing active expiration.

Authors:  Michiel de Wolf; Dietmar Enk; Narasimhan Jagannathan
Journal:  Paediatr Anaesth       Date:  2021-12-22       Impact factor: 2.129

3.  Canadian Airway Focus Group updated consensus-based recommendations for management of the difficult airway: part 1. Difficult airway management encountered in an unconscious patient.

Authors:  J Adam Law; Laura V Duggan; Mathieu Asselin; Paul Baker; Edward Crosby; Andrew Downey; Orlando R Hung; Philip M Jones; François Lemay; Rudiger Noppens; Matteo Parotto; Roanne Preston; Nick Sowers; Kathryn Sparrow; Timothy P Turkstra; David T Wong; George Kovacs
Journal:  Can J Anaesth       Date:  2021-06-18       Impact factor: 5.063

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.