Literature DB >> 33430078

Study of Long-Term Determination Accuracy for REEs in Geological Samples by Inductively Coupled Plasma Quadrupole Mass Spectrometry.

Xijuan Tan1,2, Minwu Liu1,2, Ke He1,2.   

Abstract

This work presents the long-term determination accuracy study of ICP-QMS for rare earth elements (REEs) in geological matrices. Following high-pressure closed acidic decomposition, REEs are measured repetitively across seven months by ICP-QMS. Under optimum experimental conditions (including spray chamber temperature, gas flow rate, sampling depth, etc.), the REE contents in geological standard materials from basic (basalt BCR-2 and BE-N) to intermediate (andesite AGV-2) and up to acidic (granite GSR-1) show good agreement with the certified values, giving relative errors below 10%. Here, the influence of two storage materials (perfluoroalkoxy PFA and polypropylene PP) on the long-term determination accuracy of REEs has also been monitored. It is found that the relative errors of REEs using a PFA container range from -6.6 to 6.3% (RSDs < 6.0%), while that using a PP container are within -4.0 to 3.9% (RSDs < 4.6%). By using PP material as a solution storage container, the accuracy of REEs quantification in a series of real geological samples are checked, showing the RSDs of less than 5.0%. This work first clarifies the long-term stability of REEs quantification by ICP-QMS covering two types of storage materials, confirming the reasonability of PP material as a daily storage container in terms of higher data precision and lower cost.

Entities:  

Keywords:  ICP-QMS; REE determination accuracy; geological samples; long-term stability

Mesh:

Substances:

Year:  2021        PMID: 33430078      PMCID: PMC7827012          DOI: 10.3390/molecules26020290

Source DB:  PubMed          Journal:  Molecules        ISSN: 1420-3049            Impact factor:   4.411


  10 in total

1.  Comparison of inductively coupled plasma spectrometry techniques for the direct determination of rare earth elements in digests from geological samples.

Authors:  Francisco Ardini; Francesco Soggia; Francesco Rugi; Roberto Udisti; Marco Grotti
Journal:  Anal Chim Acta       Date:  2010-07-30       Impact factor: 6.558

2.  Determination of trace rare earth elements by X-ray fluorescence spectrometry after preconcentration on a new chelating resin loaded with thorin.

Authors:  I E De Vito; A N Masi; R A Olsina
Journal:  Talanta       Date:  1999-07-12       Impact factor: 6.057

3.  Evaluation of a mirror-polishing technique for fluorocarbon polymer surfaces for reduction of contamination from containers used in ultratrace analysis.

Authors:  M Takenaka; M Hayashi; I Suzuki; Y Yamada; K Takamatsu; M Kageyama
Journal:  Anal Chem       Date:  1997-03-01       Impact factor: 6.986

4.  A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices.

Authors:  Laurence Whitty-Léveillé; Keven Turgeon; Claude Bazin; Dominic Larivière
Journal:  Anal Chim Acta       Date:  2017-01-31       Impact factor: 6.558

5.  Does bottle type and acid-washing influence trace element analyses by ICP-MS on water samples? A test covering 62 elements and four bottle types: high density polyethene (HDPE), polypropene (PP), fluorinated ethene propene copolymer (FEP) and perfluoroalkoxy polymer (PFA).

Authors:  C Reimann; U Siewers; H Skarphagen; D Banks
Journal:  Sci Total Environ       Date:  1999-10-01       Impact factor: 7.963

6.  Rare earth elements profile in a cultivated and non-cultivated soil determined by laser ablation-inductively coupled plasma mass spectrometry.

Authors:  Vinicius M Neves; Graciela M Heidrich; Flavia B Hanzel; Edson I Muller; Valderi L Dressler
Journal:  Chemosphere       Date:  2018-02-03       Impact factor: 7.086

7.  Formation of carbonatite-related giant rare-earth-element deposits by the recycling of marine sediments.

Authors:  Zengqian Hou; Yan Liu; Shihong Tian; Zhiming Yang; Yuling Xie
Journal:  Sci Rep       Date:  2015-06-02       Impact factor: 4.379

8.  Rare earth and trace element signatures for assessing an impact of rock mining and processing on the environment: Wiśniówka case study, south-central Poland.

Authors:  Zdzisław M Migaszewski; Agnieszka Gałuszka; Sabina Dołęgowska
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-25       Impact factor: 4.223

9.  Evaluation of an Element-Tagged Duplex Immunoassay Coupled with Inductively Coupled Plasma Mass Spectrometry Detection: A Further Study for the Application of the New Assay in Clinical Laboratory.

Authors:  Wencan Jiang; Gongwei Sun; Wenbin Cui; Shasha Men; Miao Jing; Danna Pu; Sichun Zhang; Xiaozhou Yuan; Xinrong Zhang; Chengbin Wang
Journal:  Molecules       Date:  2020-11-17       Impact factor: 4.411

10.  A Microwave Digestion Technique for the Analysis of Rare Earth Elements, Thorium and Uranium in Geochemical Certified Reference Materials and Soils by Inductively Coupled Plasma Mass Spectrometry.

Authors:  Sharayu Kasar; Rajamanickam Murugan; Hideki Arae; Tatsuo Aono; Sarata Kumar Sahoo
Journal:  Molecules       Date:  2020-11-06       Impact factor: 4.411

  10 in total
  1 in total

1.  Energy Efficiency Enhancement of Inductively Coupled Plasma Torch: Computational Study.

Authors:  Samira Elaissi; Amira Ben Gouider Trabelsi; Fatemah H Alkallas; Tahani A Alrebdi; Kamel Charrada
Journal:  Materials (Basel)       Date:  2022-07-28       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.