Literature DB >> 28224906

A comparative study of sample dissolution techniques and plasma-based instruments for the precise and accurate quantification of REEs in mineral matrices.

Laurence Whitty-Léveillé1, Keven Turgeon1, Claude Bazin2, Dominic Larivière3.   

Abstract

The recent commercialisation of inductively coupled plasma tandem mass spectrometric (ICP-MS/MS) instruments has provided analytical chemists with a new tool to properly quantify atomic composition in a variety of matrices with minimal sample preparation. In this article, we report on our assessment of the compatibility of 3 sample preparation techniques (open-vessel acid digestion, microwave digestion and alkaline fusion) for the quantification of rare earth elements (REEs) in mineral matrices. The combination of the high digestion temperatures (1050 °C) and using LiBO2 as a flux was the most effective strategy for the digestion of all rare earth elements in mineral matrices and was compatible with ICP-MS/MS measurements. We also assessed the analytical performances of ICP-MS/MS against other plasma-based instrumentation (microwave induced plasma and inductively coupled plasma atomic emission spectroscopy (MIP-AES and ICP-AES, respectively) and single quadrupole inductively coupled plasma mass spectrometry (ICP-MS). The comparative study showed that the concentrations obtained by ICP-MS/MS are in excellent agreement with the certified reference material values, and much more suited than the other analytical techniques tested for the quantification of REEs, which exhibited low detectability and/or spectral interferences for some elements/isotopes. Finally, the ruggedness of the analytical protocol proposed which combines a rapid sample dissolution step performed by an automated fusion unit and an ICP-MS/MS as a detector was established using various certified mineral matrices containing variable levels of REEs.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alkaline fusion; Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS); Microwave digestion; Microwave induced plasma atomic emission spectroscopy (MIP-AES); Rare earth elements

Year:  2017        PMID: 28224906     DOI: 10.1016/j.aca.2017.01.045

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Study of Long-Term Determination Accuracy for REEs in Geological Samples by Inductively Coupled Plasma Quadrupole Mass Spectrometry.

Authors:  Xijuan Tan; Minwu Liu; Ke He
Journal:  Molecules       Date:  2021-01-08       Impact factor: 4.411

2.  Determination of major elements in igneous rocks using microwave plasma atomic emission spectrometry (MP-AES).

Authors:  María Cecilia Geisenblosen; Pedro Oyhantçabal; Mariela Pistón
Journal:  MethodsX       Date:  2022-07-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.