Literature DB >> 33419341

Efficacy of Inertial Measurement Units in the Evaluation of Trunk and Hand Kinematics in Baseball Hitting.

Niroshan G Punchihewa1, Shigeaki Miyazaki2, Etsuo Chosa2, Go Yamako3.   

Abstract

Baseball hitting is a highly dynamic activity, and advanced methods are required to accurately obtain biomechanical data. Inertial measurement units (IMUs) can capture the motion of body segments at high sampling rates both indoor and outdoor. The bat rotates around the longitudinal axis of the body; thus, trunk motion plays a key role in baseball hitting. Segmental coordination is important in transferring power to a moving ball and, therefore, useful in evaluating swing kinematics. The current study aimed to investigate the validity and reliability of IMUs with a sampling rate of 1000 Hz attached on the pelvis, thorax, and hand in assessing trunk and hand motion during baseball hitting. Results obtained using the IMU and optical motion capture system (OMCS) were compared. Angular displacements of the trunk segments and spine joint had a root mean square error of <5°. The mean absolute error of the angular velocities was ≤5%. The intra-class correlation coefficient (>0.950) had excellent reliability for trunk kinematics along the longitudinal-axis. Hand velocities at peak and impact corresponded to the values determined using the OMCS. In conclusion, IMUs with high sampling rates are effective in evaluating trunk and hand movement coordination during hitting motion.

Entities:  

Keywords:  accuracy; baseball batting; coordination; inertial sensors; motion analysis; reliability; trunk kinematics

Mesh:

Year:  2020        PMID: 33419341      PMCID: PMC7766213          DOI: 10.3390/s20247331

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  26 in total

1.  Abdominal muscle strains in professional baseball: 1991-2010.

Authors:  Stan A Conte; Matthew M Thompson; Matthew A Marks; Joshua S Dines
Journal:  Am J Sports Med       Date:  2012-01-19       Impact factor: 6.202

2.  Bat speed, trajectory, and timing for collegiate baseball batters hitting a stationary ball.

Authors:  Noriyuki Tabuchi; Tomoyuki Matsuo; Ken Hashizume
Journal:  Sports Biomech       Date:  2007-01       Impact factor: 2.832

3.  Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system.

Authors:  Corina Nüesch; Elena Roos; Geert Pagenstert; Annegret Mündermann
Journal:  J Biomech       Date:  2017-03-21       Impact factor: 2.712

4.  Kinetic analysis of the lower limbs in baseball tee batting.

Authors:  Kazumichi Ae; Sekiya Koike; Norihisa Fujii; Michiyoshi Ae; Takashi Kawamura
Journal:  Sports Biomech       Date:  2017-02-28       Impact factor: 2.832

5.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

6.  Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal.

Authors:  G K Cole; B M Nigg; J L Ronsky; M R Yeadon
Journal:  J Biomech Eng       Date:  1993-11       Impact factor: 2.097

7.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

8.  Trunk axial rotation in baseball pitching and batting.

Authors:  Glenn S Fleisig; Wellington K Hsu; Dave Fortenbaugh; Andrew Cordover; Joel M Press
Journal:  Sports Biomech       Date:  2013-11       Impact factor: 2.832

9.  How Angular Velocity Features and Different Gyroscope Noise Types Interact and Determine Orientation Estimation Accuracy.

Authors:  Ilaria Pasciuto; Gabriele Ligorio; Elena Bergamini; Giuseppe Vannozzi; Angelo Maria Sabatini; Aurelio Cappozzo
Journal:  Sensors (Basel)       Date:  2015-09-18       Impact factor: 3.576

10.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity.

Authors:  Mohammad Al-Amri; Kevin Nicholas; Kate Button; Valerie Sparkes; Liba Sheeran; Jennifer L Davies
Journal:  Sensors (Basel)       Date:  2018-02-28       Impact factor: 3.576

View more
  3 in total

1.  Impact Position Estimation for Baseball Batting with a Force-Irrelevant Vibration Feature.

Authors:  Wei-Han Chen; Yang-Chih Feng; Ming-Chia Yeh; Hsi-Pin Ma; Chiang Liu; Cheng-Wen Wu
Journal:  Sensors (Basel)       Date:  2022-02-17       Impact factor: 3.576

2.  Accuracy of a markerless motion capture system in estimating upper extremity kinematics during boxing.

Authors:  Bhrigu K Lahkar; Antoine Muller; Raphaël Dumas; Lionel Reveret; Thomas Robert
Journal:  Front Sports Act Living       Date:  2022-07-25

3.  Trunk Posture from Randomly Oriented Accelerometers.

Authors:  Aidan R W Friederich; Musa L Audu; Ronald J Triolo
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.