Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system.

Corina Nüesch1, Elena Roos2, Geert Pagenstert3, Annegret Mündermann4.   

Abstract

Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Keywords:  Agreement; Inertial sensors; Kinematics; Running; Walking

Mesh:

Year:  2017        PMID: 28366438     DOI: 10.1016/j.jbiomech.2017.03.015

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  30 in total

1.  Patterns of intermuscular inhibitory force feedback across cat hindlimbs suggest a flexible system for regulating whole limb mechanics.

Authors:  Mark A Lyle; T Richard Nichols
Journal:  J Neurophysiol       Date:  2017-11-15       Impact factor: 2.714

2.  Prediction of lower limb joint angles and moments during gait using artificial neural networks.

Authors:  Marion Mundt; Wolf Thomsen; Tom Witter; Arnd Koeppe; Sina David; Franz Bamer; Wolfgang Potthast; Bernd Markert
Journal:  Med Biol Eng Comput       Date:  2019-12-11       Impact factor: 2.602

3.  Wearables for Running Gait Analysis: A Systematic Review.

Authors:  Rachel Mason; Liam T Pearson; Gillian Barry; Fraser Young; Oisin Lennon; Alan Godfrey; Samuel Stuart
Journal:  Sports Med       Date:  2022-10-15       Impact factor: 11.928

4.  Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis.

Authors:  Ziwei Zeng; Yue Liu; Xiaoyue Hu; Meihua Tang; Lin Wang
Journal:  Sports Med Open       Date:  2022-06-27

5.  Functional movement assessment by means of inertial sensor technology to discriminate between movement behaviour of healthy controls and persons with knee osteoarthritis.

Authors:  Rob van der Straaten; Mariska Wesseling; Ilse Jonkers; Benedicte Vanwanseele; Amber K B D Bruijnes; Jan Malcorps; Johan Bellemans; Jan Truijen; Liesbet De Baets; Annick Timmermans
Journal:  J Neuroeng Rehabil       Date:  2020-05-19       Impact factor: 4.262

6.  Kinematics and temporospatial parameters during gait from inertial motion capture in adults with and without HIV: a validity and reliability study.

Authors:  Karina Berner; John Cockcroft; Quinette Louw
Journal:  Biomed Eng Online       Date:  2020-07-24       Impact factor: 2.819

7.  Validation of a portable marker-based motion analysis system.

Authors:  Shaobai Wang; Xiaolong Zeng; Liang Huangfu; Zhenyan Xie; Limin Ma; Wenhan Huang; Yu Zhang
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

8.  Inertial Sensor-Based Motion Analysis of Lower Limbs for Rehabilitation Treatments.

Authors:  Tongyang Sun; Hua Li; Quanquan Liu; Lihong Duan; Meng Li; Chunbao Wang; Qihong Liu; Weiguang Li; Wanfeng Shang; Zhengzhi Wu; Yulong Wang
Journal:  J Healthc Eng       Date:  2017-07-05       Impact factor: 2.682

9.  Validity, Test-Retest Reliability and Long-Term Stability of Magnetometer Free Inertial Sensor Based 3D Joint Kinematics.

Authors:  Wolfgang Teufl; Markus Miezal; Bertram Taetz; Michael Fröhlich; Gabriele Bleser
Journal:  Sensors (Basel)       Date:  2018-06-21       Impact factor: 3.576

10.  Reliability of 3D Lower Extremity Movement Analysis by Means of Inertial Sensor Technology during Transitional Tasks.

Authors:  Rob van der Straaten; Annick Timmermans; Amber K B D Bruijnes; Benedicte Vanwanseele; Ilse Jonkers; Liesbet De Baets
Journal:  Sensors (Basel)       Date:  2018-08-11       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.