BACKGROUND: Magnesium has been used as degradable fixation material for osteosynthesis, but it seems that mechanical strength is still a current issue in these fixations. The aim of this study was to evaluate the axial pull-out force of compression headless screws made of magnesium alloy during their resorption.
METHODS: The tests included screws made for osteosynthesis of the mandible head: 2.2 mm diameter magnesium alloy MgYREZr (42 screws) and 2.5 mm diameter polylactic-co-glycolic acid (PLGA) (42 pieces, control). The screws were resorbed in Sørensen's buffer for 2, 4, 8, 12, and 16 weeks, and force was measured as the screw was pulled out from the polyurethane block.
RESULTS: The force needed to pull the screw out was significantly higher for MgYREZr screws than for PLGA ones (p < 0.01). Within eight weeks, the pull-out force for MgYREZr significantly decreased to one third of its initial value (p < 0.01). The dynamics of this decrease were greater than those of the pull-out force for PLGA screws (p < 0.05). After these eight weeks, the values for metal and polymer screws equalized. It seems that the described reduction of force requires taking into account when using magnesium screws. This will provide more stable resorbable metallic osteosynthesis.

Entities:  

Keywords:  condylar head fracture; fixation material; magnesium; mandible; polyglycolic acid; polylactide; pull-out force; screw

Year:  2021        PMID: 33418924     DOI: 10.3390/ma14020237

Source DB:  PubMed          Journal:  Materials (Basel)        ISSN: 1996-1944            Impact factor:   3.623


  3 in total

1.  Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head.

Authors:  Marcin Kozakiewicz; Izabela Gabryelczak; Bartosz Bielecki-Kowalski
Journal:  Materials (Basel)       Date:  2022-01-18       Impact factor: 3.623

Review 2.  Variants and Modifications of the Retroauricular Approach Using in Temporomandibular Joint Surgery: A Systematic Review.

Authors:  Maciej Sikora; Maciej Chęciński; Zuzanna Nowak; Dariusz Chlubek
Journal:  J Clin Med       Date:  2021-05-11       Impact factor: 4.241

3.  Bone Union Quality after Fracture Fixation of Mandibular Head with Compression Magnesium Screws.

Authors:  Marcin Kozakiewicz; Izabela Gabryelczak
Journal:  Materials (Basel)       Date:  2022-03-17       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.