PURPOSE: To evaluate the efficacy and safety of an ab externo suture retrieval and scleral fixation technique in the treatment of subluxated posterior chamber intraocular lenses (PC IOLs).
SETTING: Academic tertiary care centers.
METHODS: Surgical databases from 2 surgeons were reviewed for consecutive cases from March 2000 to April 2004 in which the ab externo scleral suture fixation technique was used and a minimum follow-up of 3 months was completed. Patient charts were reviewed for 15 eyes that had decentered in-the-bag PC IOLs, 12 eyes with subluxated sulcus or bag-sulcus positioned PC IOLs, and 3 eyes with PC IOLs dislocated into the vitreous.
RESULTS: The mean time from cataract extraction to PC IOL stabilization was 3.4 years (range 2 days to 10.9 years). Surgical repositioning was successfully performed in all patients. After a mean follow-up of 14.7 months, the mean best corrected visual acuity (BCVA) improved from 20/140 to 20/40 (P = .0001). All patients had stable or improved BCVA. All patients with a successfully completed procedure achieved an adequately centered PC IOL postoperatively. One patient (3.3%) developed a significant intraoperative vitreous hemorrhage requiring the procedure to be aborted, but reoperation 3 months later was successful. Postoperative complications included persistent elevated intraocular pressure in 2 eyes (6.7%) and chronic cystoid macular edema in 1 eye (3.3%) that resolved with medication.
CONCLUSION: The ab externo suture loop retrieval and scleral fixation technique was effective in repositioning decentered, subluxated, or dislocated PC IOLs with excellent visual outcomes.

Entities:  

Mesh:

Year:  2006        PMID: 16516790     DOI: 10.1016/j.jcrs.2005.06.050

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  16 in total

1.  Ocular biocompatibility of nitinol intraocular clips.

Authors:  Jeffrey L Olson; Raul Velez-Montoya; Michael Erlanger
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-25       Impact factor: 4.799

2.  Outcome of iris fixation of subluxated intraocular lenses.

Authors:  Adi Michaeli; Uri Soiberman; Anat Loewenstein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-05-15       Impact factor: 3.117

3.  Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes.

Authors:  R Fernández-Buenaga; J L Alio; A L Pérez-Ardoy; A Larrosa-Quesada; L Pinilla-Cortés; R Barraquer; J L Alio; F J Muñoz-Negrete
Journal:  Eye (Lond)       Date:  2013-06-14       Impact factor: 3.775

Review 4.  [Iris suture fixation of posterior chamber lenses. New perspectives for an old technique].

Authors:  K Gerstmeyer; W Sekundo
Journal:  Ophthalmologe       Date:  2014-03       Impact factor: 1.059

Review 5.  Anterior chamber intraocular lens, sutured posterior chamber intraocular lens, or glued intraocular lens: where do we stand?

Authors:  Derick G Holt; Jason Young; Brian Stagg; Balamurali K Ambati
Journal:  Curr Opin Ophthalmol       Date:  2012-01       Impact factor: 3.761

6.  Scleral fixation of a one-piece toric intraocular lens.

Authors:  Matthew E Emanuel; J Bradley Randleman; Samuel Masket
Journal:  J Refract Surg       Date:  2013-02       Impact factor: 3.573

7.  Outcomes of a new suture technique for the treatment of dislocated intraocular lenses: locked loop on the haptic.

Authors:  Ugur Unsal; Berkay Akmaz; Deniz Kilic
Journal:  Int Ophthalmol       Date:  2021-06-26       Impact factor: 2.031

8.  Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses.

Authors:  J Lyu; P-Q Zhao
Journal:  Eye (Lond)       Date:  2016-01-22       Impact factor: 3.775

9.  Haptic breakage after transscleral fixation of a single-piece acrylic intraocular lens.

Authors:  Hiroki Tanaka; Kaoru Fujinami; Ken Watanabe; Toru Noda; Kunihiko Akiyama
Journal:  Case Rep Ophthalmol       Date:  2014-07-12

10.  Long-Term Suture Breakage After Scleral Fixation of a Modified Capsular Tension Ring with Polypropylene 10-0 Suture.

Authors:  Olav Kristianslund; Gunhild F Sandvik; Liv Drolsum
Journal:  Clin Ophthalmol       Date:  2021-06-14