Literature DB >> 33404870

Determinants of accuracy of freehand external ventricular drain placement by neurosurgical trainees.

Masoud Pishjoo1, Kasra Khatibi2, Hamid Etemadrezaie1, Samira Zabihyan1, Babak Ganjeifar1, Mohammad Safdari3, Humain Baharvahdat1.   

Abstract

BACKGROUND: The external ventricular drain (EVD) placement is one of the most common neurosurgical procedures. This operation is performed by freehand technique in the majority of cases; therefore, the operator's experience plays an important role in success and possible morbidity of this procedure.
OBJECTIVE: To evaluate the accuracy and safety of EVD placement by junior neurosurgery residents and factors predicting accuracy of EVD placement.
METHODS: This is a prospective cohort study conducted at our academic medical center, between September 2017 and August 2018. All patients 18 years or older who required EVD placement were included. The accuracy and complications of EVD placement were assessed in the first and second year resident cohorts as well as by their level of experience, using descriptive statistics. Univariate and multivariate models were used to assess predictive factors for optimal EVD.
RESULTS: A total of 100 EVDs were placed in 100 patients during the study period. According to Kakarla classification, the catheter was optimally placed in 80% of cases. The first year residents had a significantly higher rate of suboptimal burr hole placement compared to the second year residents (66.7% versus 27.1%, p = 0.004). The trainees with less than 10 EVD placement experience also had a significantly higher rate of suboptimal burr hole placement (55.2% vs. 23.9%, p = 0.003), significantly longer duration of operation (43.1 min ± 14.9SD vs 34.2 min ± 9.6 p = 0.005), and significantly lower rate of optimal EVD location (85.9% versus 65.5%, p = 0.023). Optimal location of the burr hole was the only significant predictor of optimal EVD placement in multivariate analysis (OR 11.9, 95% CI 3.2-44.6, p < 0.001).
CONCLUSIONS: Neurosurgery residents experience and optimal burr hole placement are the main predicators of accurate EVD placement.

Entities:  

Keywords:  External ventricular drain; Freehand method; Neurosurgery resident; Ventriculostomy

Mesh:

Year:  2021        PMID: 33404870     DOI: 10.1007/s00701-020-04671-5

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  19 in total

1.  Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans.

Authors:  David R Huyette; Benjamin J Turnbow; Christian Kaufman; Dale F Vaslow; Benjamin B Whiting; Michael Y Oh
Journal:  J Neurosurg       Date:  2008-01       Impact factor: 5.115

2.  Safety and accuracy of bedside external ventricular drain placement.

Authors:  Udaya K Kakarla; Louis J Kim; Steven W Chang; Nicholas Theodore; Robert F Spetzler
Journal:  Neurosurgery       Date:  2008-07       Impact factor: 4.654

3.  The misplacement of external ventricular drain by freehand method in emergent neurosurgery.

Authors:  Cheng-Ta Hsieh; Guann-Juh Chen; Hsin-I Ma; Cheng-Fu Chang; Cheng-Ma Cheng; Yih-Huei Su; Da-Tong Ju; Chung-Ching Hsia; Yuan-Hao Chen; Hao-Yiang Wu; Ming-Ying Liu
Journal:  Acta Neurol Belg       Date:  2011-03       Impact factor: 2.396

4.  The burden and risk factors of ventriculostomy occlusion in a high-volume cerebrovascular practice: results of an ongoing prospective database.

Authors:  Kyle M Fargen; Brian L Hoh; Dan Neal; Timothy O'connor; Marie Rivera-Zengotita; Gregory J A Murad
Journal:  J Neurosurg       Date:  2015-10-30       Impact factor: 5.115

5.  Accuracy and Safety of External Ventricular Drain Placement by Physician Assistants and Nurse Practitioners in Aneurysmal Acute Subarachnoid Hemorrhage.

Authors:  Alejandro Enriquez-Marulanda; Luis C Ascanio; Mohamed M Salem; Georgios A Maragkos; Ray Jhun; Abdulrahman Y Alturki; Justin M Moore; Christopher S Ogilvy; Ajith J Thomas
Journal:  Neurocrit Care       Date:  2018-12       Impact factor: 3.210

6.  Placement accuracy of external ventricular drain when comparing freehand insertion to neuronavigation guidance in severe traumatic brain injury.

Authors:  Ahmed AlAzri; Kelvin Mok; Jeffrey Chankowsky; Mohammad Mullah; Judith Marcoux
Journal:  Acta Neurochir (Wien)       Date:  2017-05-29       Impact factor: 2.216

7.  Ventricular catheter placement in children with hydrocephalus and small ventricles: the use of a frameless neuronavigation system.

Authors:  Ziv Gil; Vitaly Siomin; Liana Beni-Adani; Ben Sira; Shlomi Constantini
Journal:  Childs Nerv Syst       Date:  2002-01-26       Impact factor: 1.475

8.  Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback.

Authors:  P Pat Banerjee; Cristian J Luciano; G Michael Lemole; Fady T Charbel; Michael Y Oh
Journal:  J Neurosurg       Date:  2007-09       Impact factor: 5.115

9.  The Evans' Index revisited: New cut-off levels for use in radiological assessment of ventricular enlargement in the elderly.

Authors:  Maiken K Brix; Eric Westman; Andrew Simmons; Geir Andre Ringstad; Per Kristian Eide; Kari Wagner-Larsen; Christian M Page; Valeria Vitelli; Mona K Beyer
Journal:  Eur J Radiol       Date:  2017-07-20       Impact factor: 3.528

10.  Hemorrhage rates after external ventricular drain placement.

Authors:  Paul A Gardner; Johnathan Engh; Dave Atteberry; John J Moossy
Journal:  J Neurosurg       Date:  2009-05       Impact factor: 5.115

View more
  2 in total

1.  Analysis of a Novel Entry Point for Freehand Ventriculostomy Using Computerized Tomography Scans.

Authors:  Anton N Konovalov; Vadim Gadzhiagaev; Alexei A Veselkov; Dmitry Okishev; Shalva Eliava
Journal:  Cureus       Date:  2022-01-10

2.  Multimodal Simulation of a Novel Device for a Safe and Effective External Ventricular Drain Placement.

Authors:  Giuseppe Emmanuele Umana; Gianluca Scalia; Kaan Yagmurlu; Rosalia Mineo; Simone Di Bella; Matteo Giunta; Angelo Spitaleri; Rosario Maugeri; Francesca Graziano; Marco Fricia; Giovanni Federico Nicoletti; Santino Ottavio Tomasi; Giuseppe Raudino; Bipin Chaurasia; Gianluca Bellocchi; Maurizio Salvati; Domenico Gerardo Iacopino; Salvatore Cicero; Massimiliano Visocchi; Lidia Strigari
Journal:  Front Neurosci       Date:  2021-06-14       Impact factor: 4.677