Literature DB >> 33389646

Efficacy of the Wolverine cutting balloon on a circumferential calcified coronary lesion: Bench test using a three-dimensional printer and computer simulation with the finite element method.

Xiaoyang Song1, Taiji Adachi2, Yoshiaki Kawase3, Takeshi Kimura1, Naritatsu Saito4.   

Abstract

Heavy calcification is one of the factors that hinder the success of coronary angioplasty, and a cutting balloon is used for such lesions. This study aimed to explore the optimal method of dilation of highly calcified lesions using a cutting balloon. Calcification models were developed from patient computed tomography and intravascular ultrasound data, and were constructed using three-dimensional printers. The lesions were dilated using a Wolverine™ cutting balloon and NC Emerge™ noncompliant balloon catheter, and the success rate of dilation and maximum dilation pressure were compared. The maximum first principal stresses in calcified lesions were also evaluated by computer simulation using the finite element method. In the bench test, the dilation success rate of the Wolverine™ cutting balloon was higher and the maximum dilation pressure required was lower (p < 0.01 in all analyses), compared with that of the NC Emerge™ balloon catheter. Finite element analysis showed that the cutting blade increased the maximum first principal stresses in calcified lesions, thus allowing for successful dilation at low pressures. The highest stress was obtained when the cutting blade was positioned at the thinnest part of the calcification. The cutting balloon allows for efficient calcification expansion by concentrating the stresses in the blade. When a cutting balloon is used, if the calcified lesion cannot be expanded in a single dilation, dilation success may be achieved after the balloon is rotated and the position of the blade is changed.
© 2021. Japanese Association of Cardiovascular Intervention and Therapeutics.

Entities:  

Keywords:  3D printer; Calcified lesion; Computer simulation; Cutting balloon; Finite element analysis

Mesh:

Year:  2021        PMID: 33389646     DOI: 10.1007/s12928-020-00739-2

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  8 in total

1.  Vascular mechanics of the coronary artery.

Authors:  A I Veress; D G Vince; P M Anderson; J F Cornhill; E E Herderick; J D Klingensmith; B D Kuban; N L Greenberg; J D Thomas
Journal:  Z Kardiol       Date:  2000

2.  Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: an intravascular ultrasound study.

Authors:  Hiroyuki Okura; Motoya Hayase; Shinichi Shimodozono; Toru Kobayashi; Kazuya Sano; Toyoaki Matsushita; Taizo Kondo; Mikihiko Kijima; Hideo Nishikawa; Hiroyuki Kurogane; Tadanori Aizawa; Hiroaki Hosokawa; Takahiko Suzuki; Tetsu Yamaguchi; Heidi N Bonneau; Paul G Yock; Peter J Fitzgerald
Journal:  Catheter Cardiovasc Interv       Date:  2002-12       Impact factor: 2.692

3.  Utility of a scoring balloon for a severely calcified lesion: bench test and finite element analysis.

Authors:  Yoshiaki Kawase; Naritatsu Saito; Shin Watanabe; Bingyuan Bao; Erika Yamamoto; Hiroki Watanabe; Hirooki Higami; Hitoshi Matsuo; Katsumi Ueno; Takeshi Kimura
Journal:  Cardiovasc Interv Ther       Date:  2013-12-07

4.  Successful predilation of a resistant, heavily calcified lesion with cutting balloon for coronary stenting: a case report.

Authors:  Y Asakura; Y Furukawa; S Ishikawa; K Asakura; K Sueyoshi; M Sakamoto; S Takagi; S Takatsuki; K Oyamada; T Okabe; H Mitamura; S Ogawa; T Hinohara
Journal:  Cathet Cardiovasc Diagn       Date:  1998-08

5.  Effect of cutting balloon after rotational atherectomy in severely calcified coronary artery lesions as assessed by optical coherence tomography.

Authors:  Kisaki Amemiya; Myong Hwa Yamamoto; Akiko Maehara; Yuji Oyama; Wataru Igawa; Morio Ono; Takehiko Kido; Seitarou Ebara; Toshitaka Okabe; Kennosuke Yamashita; Koichi Hoshimoto; Shigeo Saito; Tadayuki Yakushiji; Naoei Isomura; Hiroshi Araki; Gary S Mintz; Masahiko Ochiai
Journal:  Catheter Cardiovasc Interv       Date:  2019-04-11       Impact factor: 2.692

Review 6.  Challenges With Severe Coronary Artery Calcification in Percutaneous Coronary Intervention: A Narrative Review of Therapeutic Options.

Authors:  Jay S Shavadia; Minh N Vo; Kevin R Bainey
Journal:  Can J Cardiol       Date:  2018-08-14       Impact factor: 5.223

7.  Impact of target lesion coronary calcification on stent expansion.

Authors:  Yuhei Kobayashi; Hiroyuki Okura; Teruyoshi Kume; Ryotaro Yamada; Yukari Kobayashi; Kenzo Fukuhara; Terumasa Koyama; Shintaro Nezuo; Yoji Neishi; Akihiro Hayashida; Takahiro Kawamoto; Kiyoshi Yoshida
Journal:  Circ J       Date:  2014-07-14       Impact factor: 2.993

8.  Cutting-balloon angioplasty before drug-eluting stent implantation for the treatment of severely calcified coronary lesions.

Authors:  Zhe Tang; Jing Bai; Shao-Ping Su; Yu Wang; Mo-Han Liu; Qi-Cai Bai; Jin-Wen Tian; Qiao Xue; Lei Gao; Chun-Xiu An; Xiao-Juan Liu
Journal:  J Geriatr Cardiol       Date:  2014-03       Impact factor: 3.327

  8 in total