Literature DB >> 24318791

Utility of a scoring balloon for a severely calcified lesion: bench test and finite element analysis.

Yoshiaki Kawase1, Naritatsu Saito, Shin Watanabe, Bingyuan Bao, Erika Yamamoto, Hiroki Watanabe, Hirooki Higami, Hitoshi Matsuo, Katsumi Ueno, Takeshi Kimura.   

Abstract

We aimed to investigate the effectiveness of a scoring balloon catheter in expanding a circumferentially calcified lesion compared to a conventional balloon catheter using an in vitro experiment setting and elucidate the underlying mechanisms of this ability using a finite element analysis. True efficacy of the scoring device and the underlying mechanisms for heavily calcified coronary lesions are unclear. We employed a Scoreflex scoring balloon catheter (OrbusNeich, Hong Kong, China). The ability of Scoreflex to dilate a calcified lesion was compared with a conventional balloon catheter using 3 different sized calcium tubes. The thickness of the calcium tubes were 2.0, 2.25, and 2.5 mm. The primary endpoints were the successful induction of cracks in the calcium tubes and the inflation pressures required for inducing cracks. The inflation pressure required for cracking the calcium tubes were consistently lower with Scoreflex (p < 0.05, Student t test). The finite element analysis revealed that the first principal stress applied to the calcified plaque was higher by at least threefold when applying the balloon catheter with scoring elements. A scoring balloon catheter can expand a calcified lesion with lower pressure than that of a conventional balloon. The finite element analysis revealed that the concentration of the stress observed in the outside of the calcified plaque just opposite to the scoring element is the underlying mechanism of the increased ability of Scoreflex to dilate the calcified lesion.

Entities:  

Mesh:

Year:  2013        PMID: 24318791     DOI: 10.1007/s12928-013-0232-6

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  3 in total

1.  Efficacy of the Wolverine cutting balloon on a circumferential calcified coronary lesion: Bench test using a three-dimensional printer and computer simulation with the finite element method.

Authors:  Xiaoyang Song; Taiji Adachi; Yoshiaki Kawase; Takeshi Kimura; Naritatsu Saito
Journal:  Cardiovasc Interv Ther       Date:  2021-01-03

Review 2.  Contemporary Approach to Heavily Calcified Coronary Lesions.

Authors:  Carlotta Sorini Dini; Giulia Nardi; Francesca Ristalli; Alessio Mattesini; Brunilda Hamiti; Carlo Di Mario
Journal:  Interv Cardiol       Date:  2019-11-18

3.  Combination therapy using scoring and sirolimus drug-coated balloons during lower limb endovascular revascularization for chronic limb threatening ischaemia: A case series.

Authors:  Tiffany Sh Bong; Charyl Jq Yap; Shereen Xy Soon; Tjun Y Tang
Journal:  SAGE Open Med Case Rep       Date:  2022-03-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.