Literature DB >> 33385003

Use of Ultrathin Bronchoscope on a Need Basis Improves Diagnostic Yield of Difficult-to-Approach Pulmonary Lesions.

Yoichi Nishii1, Yuki Nakamura1, Kentaro Fujiwara1, Kentaro Ito1, Tadashi Sakaguchi1, Yuta Suzuki1, Kazuki Furuhashi1, Tetsu Kobayashi2, Taro Yasuma3, Corina N D'Alessandro-Gabazza3, Esteban C Gabazza3, Fumihiro Asano4, Osamu Taguchi1, Osamu Hataji1.   

Abstract

There are cases of peripheral lung nodules that are difficult to approach despite using ancillary diagnostic devices during multimodal bronchoscopy. The use of ultrathin bronchoscopes has shown superiority over standard thin bronchoscopes. We retrospectively evaluated whether substitution of the thin-bronchoscope by the ultrathin device during multimodal bronchoscopy improves lesion ultrasound visualization and diagnostic yield in patients with difficult-to-approach pulmonary lesions. The study comprised 44 out of 338 patients that underwent multimodal bronchoscopy at Matsusaka Municipal Hospital. The thin-bronchoscope with an external diameter of 4 mm was substituted by the ultrathin-bronchoscope with an external diameter of 3 mm when the radial endobronchial ultrasound showed that the probe position was not within the target lesion. The median diameter of the pulmonary tumors was 17.5 mm (range: 6.0-5.2.0 mm). The endobronchial ultrasound showed the probe's position adjacent to the lesion in 12 cases and no visible lesion in 32 cases using a thin-bronchoscope. However, the endobronchial ultrasound views changed from adjacent to the lesion to within the lesion in nine cases, from no visible lesion to within the lesion in 17 cases, and from no visible lesion to adjacent to the lesion in nine cases after bronchoscope substitution. After substitution, the diagnostic yield was 80.8% in cases with the radial probe within the target lesion, 72.7% in cases with the probe adjacent to the target lesion, and 0% in cases with no visible lesion. The overall diagnostic yield was 65.9% after bronchoscope substitution. The substitution of the thin bronchoscope by the ultrathin device on a need basis improves the position of the radial endobronchial ultrasound probe and diagnostic yield of pulmonary lesions during multimodal diagnostic bronchoscopy.
Copyright © 2020 Nishii, Nakamura, Fujiwara, Ito, Sakaguchi, Suzuki, Furuhashi, Kobayashi, Yasuma, D'Alessandro-Gabazza, Gabazza, Asano, Taguchi and Hataji.

Entities:  

Keywords:  diagnostic bronchoscopy; endobronchial ultrasound; peripheral pulmonary lesion; thin bronchoscope; ultrathin bronchoscope

Year:  2020        PMID: 33385003      PMCID: PMC7771655          DOI: 10.3389/fmed.2020.588048

Source DB:  PubMed          Journal:  Front Med (Lausanne)        ISSN: 2296-858X


  15 in total

1.  Endobronchial ultrasonography using a guide sheath increases the ability to diagnose peripheral pulmonary lesions endoscopically.

Authors:  Noriaki Kurimoto; Teruomi Miyazawa; Seiji Okimasa; Akihiro Maeda; Hiroshi Oiwa; Yuka Miyazu; Masaki Murayama
Journal:  Chest       Date:  2004-09       Impact factor: 9.410

2.  Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions. A Randomized Trial.

Authors:  Masahide Oki; Hideo Saka; Masahiko Ando; Fumihiro Asano; Noriaki Kurimoto; Katsuhiko Morita; Chiyoe Kitagawa; Yoshihito Kogure; Teruomi Miyazawa
Journal:  Am J Respir Crit Care Med       Date:  2015-08-15       Impact factor: 21.405

3.  Virtual bronchoscopic navigation combined with ultrathin bronchoscopy. A randomized clinical trial.

Authors:  Fumihiro Asano; Naofumi Shinagawa; Takashi Ishida; Joe Shindoh; Masaki Anzai; Akifumi Tsuzuku; Satoshi Oizumi; Satoshi Morita
Journal:  Am J Respir Crit Care Med       Date:  2013-08-01       Impact factor: 21.405

4.  Diagnostic utility of additional conventional techniques after endobronchial ultrasonography guidance during transbronchial biopsy.

Authors:  Kei Kunimasa; Motoko Tachihara; Daisuke Tamura; Shuntaro Tokunaga; Kyosuke Nakata; Nobuko Hazeki; Hiroshi Kamiryo; Kazuyuki Kobayashi; Yasuhiro Sakai; Yoshihiro Nishimura
Journal:  Respirology       Date:  2016-06-01       Impact factor: 6.424

5.  Factors related to diagnostic yield of transbronchial biopsy using endobronchial ultrasonography with a guide sheath in small peripheral pulmonary lesions.

Authors:  Noriyuki Yamada; Koichi Yamazaki; Noriaki Kurimoto; Hajime Asahina; Eiki Kikuchi; Naofumi Shinagawa; Satoshi Oizumi; Masaharu Nishimura
Journal:  Chest       Date:  2007-06-15       Impact factor: 9.410

6.  Comparison of ultrathin bronchoscopy with conventional bronchoscopy for the diagnosis of peripheral lung lesions without virtual bronchial navigation.

Authors:  Toshiyuki Sumi; Takumi Ikeda; Takeyuki Sawai; Naoki Shijubou; Kenichi Kure; Yuichi Yamada; Hisashi Nakata; Yuji Mori; Hiroki Takahashi
Journal:  Respir Investig       Date:  2020-04-01

7.  Standard Bronchoscopy With Fluoroscopy vs Thin Bronchoscopy and Radial Endobronchial Ultrasound for Biopsy of Pulmonary Lesions: A Multicenter, Prospective, Randomized Trial.

Authors:  Nichole T Tanner; Lonny Yarmus; Alexander Chen; Jessica Wang Memoli; Hiren J Mehta; Nicholas J Pastis; Hans Lee; Michael A Jantz; Paul J Nietert; Gerard A Silvestri
Journal:  Chest       Date:  2018-08-23       Impact factor: 9.410

8.  CT-guided transbronchial biopsy using an ultrathin bronchoscope with virtual bronchoscopic navigation.

Authors:  Naofumi Shinagawa; Koichi Yamazaki; Yuya Onodera; Kazuo Miyasaka; Eiki Kikuchi; Hirotoshi Dosaka-Akita; Masaharu Nishimura
Journal:  Chest       Date:  2004-03       Impact factor: 9.410

9.  Virtual bronchoscopic navigation combined with endobronchial ultrasound to diagnose small peripheral pulmonary lesions: a randomised trial.

Authors:  Takashi Ishida; Fumihiro Asano; Koichi Yamazaki; Naofumi Shinagawa; Satoshi Oizumi; Hiroshi Moriya; Mitsuru Munakata; Masaharu Nishimura
Journal:  Thorax       Date:  2011-07-11       Impact factor: 9.139

10.  Factors leading to failure to diagnose pulmonary malignant tumors using endobronchial ultrasound with guide sheath within the target lesion.

Authors:  Yoichi Nishii; Taro Yasuma; Kentaro Ito; Yuta Suzuki; Fumiaki Watanabe; Tetsu Kobayashi; Kota Nishihama; Corina N D'Alessandro-Gabazza; Hajime Fujimoto; Esteban C Gabazza; Fumihiro Asano; Osamu Taguchi; Osamu Hataji
Journal:  Respir Res       Date:  2019-09-12
View more
  2 in total

1.  The Potential of Digital Polymerase Chain Reaction for Improving Diagnostic Yield of Nontuberculous Mycobacteria Pulmonary Disease.

Authors:  Yoichi Nishii; Kazuki Furuhashi; Saki Nakamura; Miho Nishio; Yuki Nakamura; Kengo Ushiro; Kentaro Ito; Tadashi Sakaguchi; Yuta Suzuki; Kentaro Fujiwara; Taro Yasuma; Tetsu Kobayashi; Corina D'Alessandro-Gabazza; Esteban C Gabazza; Osamu Taguchi; Osamu Hataji
Journal:  Infect Drug Resist       Date:  2021-12-01       Impact factor: 4.003

Review 2.  Advanced Bronchoscopic Technologies for Biopsy of the Pulmonary Nodule: A 2021 Review.

Authors:  Micah Z Levine; Sam Goodman; Robert J Lentz; Fabien Maldonado; Otis B Rickman; James Katsis
Journal:  Diagnostics (Basel)       Date:  2021-12-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.