Literature DB >> 33384729

Clinical Utility of Coil in Plug Method (CIP) for Internal Iliac Artery Embolization during Endovascular Aortic Aneurysm Repair.

Akiyuki Kotoku1, Yukihisa Ogawa1, Kiyoshi Chiba2, Takaaki Maruhashi2,3, Hidefumi Mimura1, Takeshi Miyairi2, Hiroshi Nishimaki2.   

Abstract

Objective: To evaluate the clinical utility of the coil in plug (CIP) method in internal iliac artery (IIA) embolization during endovascular aortic aneurysm repair (EVAR) compared to conventional coil embolization (CCE). Material and
Methods: From July to December 2018, 10 patients who underwent IIA embolization during EVAR were divided into CIP (n=5) and CCE (n=5) groups. In the CIP technique, the AVP-1 with a size more than 30%-50% of that of the embolized IIA diameter was used. The AVP-1 was deployed in the IIA. Before detachment of the AVP-1, a 2.2-F micro catheter was inserted through the 6-F delivery guiding sheath, and entered the plug. The AVP-1 was then packed with hydrogel micro coils. We compared number of coils used, embolization length, embolization time, volume embolization ratio, and embolic material cost between the groups.
Results: The CIP method achieved shorter embolization length with fewer coils used compared to CCE. The CIP method decreased the cost of total embolic materials.
Conclusion: The CIP method can achieve shorter embolization length with fewer coils used compared to CCE.
© 2020 The Editorial Committee of Annals of Vascular Diseases.

Entities:  

Keywords:  EVAR; coil in plug; embolization; internal iliac artery

Year:  2020        PMID: 33384729      PMCID: PMC7751075          DOI: 10.3400/avd.oa.20-00034

Source DB:  PubMed          Journal:  Ann Vasc Dis        ISSN: 1881-641X


  8 in total

Review 1.  The Amplatzer Vascular Plug: Review of Evolution and Current Applications.

Authors:  Jorge E Lopera
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

2.  Initial clinical experience using the Amplatzer Vascular Plug.

Authors:  David J Tuite; David O Kessel; Anthony A Nicholson; Jai V Patel; Simon J McPherson; David R Shaw
Journal:  Cardiovasc Intervent Radiol       Date:  2007 Jul-Aug       Impact factor: 2.740

3.  Internal Coil Packing for Mesh Occlusion Device.

Authors:  Masamichi Koganemaru; Norimitsu Tanaka; Shuji Nagata; Toshi Abe
Journal:  J Vasc Interv Radiol       Date:  2017-08       Impact factor: 3.464

4.  Ultrashort-Segment Embolization of High-Flow Vessels Using a Coil Packing Technique in an Amplatzer Vascular Plug.

Authors:  Yoshiaki Katada; Shiro Onozawa; Shoichi Takahashi; Shigeru Suzuki
Journal:  J Endovasc Ther       Date:  2018-10-10       Impact factor: 3.487

5.  Internal Coil Packing of an Amplatzer Vascular Plug after Incomplete Occlusion of the Afferent Vessel of a Splenic Artery Aneurysm.

Authors:  Masamichi Koganemaru; Shuichi Tanoue; Asako Kuhara; Tomoko Kugiyama; Shuji Nagata; Norimitsu Tanaka; Toshi Abe
Journal:  J Vasc Interv Radiol       Date:  2018-09       Impact factor: 3.464

6.  Recurrent rupture of a hypogastric aneurysm caused by spontaneous recanalization of an Amplatzer vascular plug.

Authors:  Eric J Dorenberg; Geir Hafsahl; Rune Andersen; Kirsten Krohg-Sørensen
Journal:  J Vasc Interv Radiol       Date:  2006-06       Impact factor: 3.464

Review 7.  Systematic Review and Meta-analysis of the Effect of Internal Iliac Artery Exclusion for Patients Undergoing EVAR.

Authors:  D C Bosanquet; C Wilcox; L Whitehurst; A Cox; I M Williams; C P Twine
Journal:  Eur J Vasc Endovasc Surg       Date:  2017-02-24       Impact factor: 7.069

8.  Distal internal iliac artery embolization: a procedure to avoid.

Authors:  Boonprasit Kritpracha; John P Pigott; Charles I Price; Todd E Russell; Mary Jo Corbey; Hugh G Beebe
Journal:  J Vasc Surg       Date:  2003-05       Impact factor: 4.268

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.