| Literature DB >> 33353381 |
Manish Devendra Mair1, Mohammed Hussain1, Saad Siddiqui1, Sudip Das1, Andrew Baker1, Peter Conboy1, Theodoros Valsamakis1, Javed Uddin1, Peter Rea1.
Abstract
OBJECTIVE: To perform a systematic review and meta-analysis to compare the diagnostic accuracy of CT and initial reverse transcriptase polymerase chain reaction (RT-PCR) for detecting COVID-19 infection.Entities:
Mesh:
Year: 2021 PMID: 33353381 PMCID: PMC8011239 DOI: 10.1259/bjr.20201039
Source DB: PubMed Journal: Br J Radiol ISSN: 0007-1285 Impact factor: 3.039
Figure 1.Literature search process is detailed in the PRISMA flow diagram
Demographic characteristics of the studies reporting diagnostic accuracy of computed tomography(CT) and reverse transcriptase-polymerase chain reaction (RT-PCR)
| Author | Type of study | Month of publication | Sample size | COVID negative patients | Mean Age | Male | Female | Reference standard taken |
|---|---|---|---|---|---|---|---|---|
| He et al17 | Retrospective | Apr-20 | 82 | 48 | 52/37 | 49 | 33 | RT-PCR |
| Fang Y et al18 | Retrospective | Apr-20 | 51 | 0 | 45 | 29 | 22 | RT-PCR |
| Bernheim et al19 | Retrospective | Feb-20 | 121 | 0 | 45 | 61 | 60 | RT-PCR |
| Jian Wu et al20 | Retrospective | Apr-20 | 80 | 0 | 46.1 | 39 | 41 | Epidemiology/clinical/RT-PCR |
| Xie et al21 | Retrospective | Apr-20 | 19 | 0 | 33 | 8 | 11 | Clinical |
| Tao Ai et al8 | Retrospective | Feb-20 | 1014 | 399 | 51 | 467 | 547 | RT-PCR |
| Chan et al26 | Retrospective | Jan-20 | 6 | 0 | 40.6 | 3 | 4 | Clinical |
| Zhang et al29 | Retrospective | Mar-20 | 14 | 0 | 41 | 7 | 7 | RT-PCR |
| Gietema et al24 | Prospective | Apr-20 | 193 | 110 | 66 | 113 | 80 | RT-PCR |
| Long et al23 | Retrospective | May-20 | 87 | 51 | 44.8 | 20 | 16 | RT-PCR |
| Xie et al25 | Retrospective | Apr-20 | 167 | 0 | – | – | – | RT-PCR |
Figure 2.a and b: Risk of bias and applicability concerns summary and graph.
Figure 3.Forest plots of sensitivities and specificities of the CT and RT-PCR for COVID-19 testing.
Figure 4.The pooled sensitivity of CT and RT-PCR.
Figure 5.Hierarchical summary Receiver operating curve (HSROC) curves.
Pooled Sensitivity and Specificity of CT scan and initial RT-PCR
| Sensitivity (95% CI) | Sensitivity (95% CI) | Specificity | ||
|---|---|---|---|---|
| CT scan | 0.91 (0.84–0.97) | 0.95 (0.88–0.98) | 0.31 (0.35–0.84) | 0.0000 |
| Initial RT-PCR | 0.84 (0.71–0.94) | 0.91 (0.80–0.96) | 1.00 (0.96–1.00) | – |