Literature DB >> 33352414

Robust scan synchronized force-fluorescence imaging.

Patrick Schmidt1, John Lajoie2, Sanjeevi Sivasankar3.   

Abstract

Simultaneous atomic force microscope (AFM) and sample scanning confocal fluorescence microscope measurements are widely used to obtain mechanistic and structural insights into protein dynamics in live cells. However, the absence of a robust technique to synchronously scan both AFM and confocal microscope piezo stages makes it difficult to visualize force-induced changes in fluorescent protein distribution in cells.  To address this challenge, we have built an integrated AFM-confocal fluorescence microscope platform that implements a synchronous scanning method which eliminates image artifacts from piezo motion ramping, produces accurate pixel binning and enables the collection of a scanned image of a sample while applying force to a single point on the sample. As proof of principle, we use this instrument to monitor the redistribution of fluorescent E-cadherin, an essential transmembrane protein, in live cells, upon application of mechanical force.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  AFM-sample scanning confocal microscope; Integrated AFM–fluorescence microscope; Point scanning; Simultaneous force-fluorescence measurements; Synchronized scanning

Mesh:

Substances:

Year:  2020        PMID: 33352414      PMCID: PMC8761069          DOI: 10.1016/j.ultramic.2020.113165

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  15 in total

1.  Fluorescence axial localization with nanometer accuracy and precision.

Authors:  Hui Li; Chi-Fu Yen; Sanjeevi Sivasankar
Journal:  Nano Lett       Date:  2012-06-25       Impact factor: 11.189

2.  Combined AFM and confocal fluorescence microscope for applications in bio-nanotechnology.

Authors:  R Kassies; K O van der Werf; A Lenferink; C N Hunter; J D Olsen; V Subramaniam; C Otto
Journal:  J Microsc       Date:  2005-01       Impact factor: 1.758

3.  Atomic force microscopy and confocal laser scanning microscopy on the cytoskeleton of permeabilised and embedded cells.

Authors:  Karl Meller; Carsten Theiss
Journal:  Ultramicroscopy       Date:  2005-11-28       Impact factor: 2.689

4.  Triggering enzymatic activity with force.

Authors:  Hermann Gumpp; Elias M Puchner; Julia L Zimmermann; Ulrich Gerland; Hermann E Gaub; Kerstin Blank
Journal:  Nano Lett       Date:  2009-09       Impact factor: 11.189

5.  Local measurements of viscoelastic parameters of adherent cell surfaces by magnetic bead microrheometry.

Authors:  A R Bausch; F Ziemann; A A Boulbitch; K Jacobson; E Sackmann
Journal:  Biophys J       Date:  1998-10       Impact factor: 4.033

6.  Comparison of viscoelastic properties of cancer and normal thyroid cells on different stiffness substrates.

Authors:  Carmela Rianna; Manfred Radmacher
Journal:  Eur Biophys J       Date:  2016-09-19       Impact factor: 1.733

7.  Single-molecule studies of classical and desmosomal cadherin adhesion.

Authors:  Andrew Vae Priest; Ramesh Koirala; Sanjeevi Sivasankar
Journal:  Curr Opin Biomed Eng       Date:  2019-09-28

8.  Tip-enhanced fluorescence microscopy at 10 nanometer resolution.

Authors:  Jordan M Gerton; Lawrence A Wade; Guillaume A Lessard; Z Ma; Stephen R Quake
Journal:  Phys Rev Lett       Date:  2004-10-28       Impact factor: 9.161

9.  Correlating confocal microscopy and atomic force indentation reveals metastatic cancer cells stiffen during invasion into collagen I matrices.

Authors:  Jack R Staunton; Bryant L Doss; Stuart Lindsay; Robert Ros
Journal:  Sci Rep       Date:  2016-01-27       Impact factor: 4.379

10.  Method for high frequency tracking and sub-nm sample stabilization in single molecule fluorescence microscopy.

Authors:  Patrick D Schmidt; Benjamin H Reichert; John G Lajoie; Sanjeevi Sivasankar
Journal:  Sci Rep       Date:  2018-09-17       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.