Literature DB >> 33344191

Study of corneal biomechanical properties in patients with childhood glaucoma.

Sara Garcia Caride1, Lucia Perucho González1, Federico Sáenz Francés1, Julián García Feijoo1.   

Abstract

AIM: To study of corneal biomechanical properties and intraocular pressure (IOP) measured with Corvis Scheimpflug Technology (ST) in patients with childhood glaucoma (CG).
METHODS: Cross-sectional study in which 89 eyes were included 56 of them with CG. Only one eye per patient was included. The following variables were obtained from the clinical history and the ophthalmological examination: age, sex, IOP, number of surgeries, and the cup/disc ratio (CDR). The following parameters were recorded using Corvis ST: corrected by biomechanics IOP (bIOP), not corrected IOP (nctIOP), central corneal thickness (CCT), maximum concavity [radius, peak distance (PD) and deformation amplitude], applanation 1 and 2 (length and velocity). The mean age was 23±14.55 and 33±19.5 years old for the control group and CG group, respectively. Totally 36 were males and 53 were females. In the CG group, 7 patients were controlled only with medical treatment. Sixteen had at least one previous goniotomy, 19 had at least one trabeculectomy, and 11 had an Ahmed implant.
RESULTS: A significant and positive intraclass correlation coefficient was found between Goldman IOP and the IOP measured by Corvis in both groups. No differences were found between the IOP measured with Corvis and Goldman using a student t-test. Regarding biomechanical parameters, there were differences in the applanation length 2 (A-L2), in the applanation velocity 2 (A-V2) and in the PD. By sex, only the applanation length 1 (A-L1) was found to be different in control group. A positive and significant Pearson correlation was found between CDR and the A-L1.
CONCLUSION: Corneal biomechanical properties have shown differences between CG and healthy subjects and also between men and women. International Journal of Ophthalmology Press.

Entities:  

Keywords:  Corvis Scheimpflug Technology; biomechanical properties; childhood glaucoma

Year:  2020        PMID: 33344191      PMCID: PMC7708360          DOI: 10.18240/ijo.2020.12.12

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  21 in total

1.  Biomechanical changes in the sclera of monkey eyes exposed to chronic IOP elevations.

Authors:  Michaël J A Girard; J-K Francis Suh; Michael Bottlang; Claude F Burgoyne; J Crawford Downs
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-07-29       Impact factor: 4.799

2.  [Correlation between intraocular pressure, paquimetry and keratometry in a normal population].

Authors:  H Sánchez-Tocino; R Bringas-Calvo; D Iglesias-Cortiñas
Journal:  Arch Soc Esp Oftalmol       Date:  2007-05

3.  Changes in the extracellular matrix of the human optic nerve head in primary open-angle glaucoma.

Authors:  M R Hernandez; W M Andrzejewska; A H Neufeld
Journal:  Am J Ophthalmol       Date:  1990-02-15       Impact factor: 5.258

4.  Assessment of ocular biomechanics using dynamic ultra high-speed Scheimpflug imaging in keratoconic and normal eyes.

Authors:  Lei Tian; Match W L Ko; Li-ke Wang; Jia-ying Zhang; Tian-jie Li; Yi-fei Huang; Yong-ping Zheng
Journal:  J Refract Surg       Date:  2014-10-07       Impact factor: 3.573

5.  Corneal hysteresis and visual field asymmetry in open angle glaucoma.

Authors:  Aashish Anand; Carlos Gustavo V De Moraes; Christopher C Teng; Celso Tello; Jeffrey M Liebmann; Robert Ritch
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-23       Impact factor: 4.799

6.  Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer.

Authors:  Caitriona Kirwan; Michael O'Keefe; Bernadette Lanigan
Journal:  Am J Ophthalmol       Date:  2006-09-01       Impact factor: 5.258

7.  [Comparison between Goldmann, Icare Pro and Corvis ST tonometry].

Authors:  P Bañeros-Rojas; J M Martinez de la Casa; P Arribas-Pardo; C Berrozpe-Villabona; P Toro-Utrera; J García-Feijoó
Journal:  Arch Soc Esp Oftalmol       Date:  2014-05-10

8.  Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera.

Authors:  Bruno Freitas Valbon; Renato Ambrósio; Bruno Machado Fontes; Milton Ruiz Alves
Journal:  Arq Bras Oftalmol       Date:  2013 Jul-Aug       Impact factor: 0.872

9.  A new tonometer--the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers.

Authors:  Jiaxu Hong; Jianjiang Xu; Anji Wei; Sophie X Deng; Xinhan Cui; Xiaobo Yu; Xinghuai Sun
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-01-23       Impact factor: 4.799

10.  Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST.

Authors:  Bernardo T Lopes; Cynthia J Roberts; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Sven Reisdorf; Stefanie Berger; Robert Koprowski; Renato Ambrósio
Journal:  J Ophthalmol       Date:  2017-06-06       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.