Literature DB >> 33332814

Changes in the Plethysmographic Perfusion Index During an End-Expiratory Occlusion Detect a Positive Passive Leg Raising Test.

Alexandra Beurton1,2, Francesco Gavelli1, Jean-Louis Teboul1,2, Nello De Vita1, Xavier Monnet1,2.   

Abstract

OBJECTIVES: The end-expiratory occlusion test for assessing preload responsiveness consists in interrupting mechanical ventilation for 15 seconds at end-expiration and measuring the cardiac index changes. The perfusion index is the ratio between the pulsatile and the nonpulsatile portions of the plethysmography signal and is, in part, determined by stroke volume. We tested whether the end-expiratory occlusion-induced changes in perfusion index could detect a positive passive leg raising test, suggesting preload responsiveness.
DESIGN: Observational study.
SETTING: Medical ICU. PATIENTS: Thirty-one ventilated patients without atrial fibrillation.
INTERVENTIONS: We measured perfusion index (Radical-7 device; Masimo Corp., Irvine, CA) and cardiac index (PiCCO2; Pulsion Medical Systems, Feldkirchen, Germany) before and during a passive leg raising test and a 15-second end-expiratory occlusion.
MEASUREMENTS AND MAIN RESULTS: In 19 patients with a positive passive leg raising test (increase in cardiac index ≥ 10%), compared to the baseline value and expressed as a relative change, passive leg raising increased cardiac index and perfusion index by 17% ± 7% and 49% ± 23%, respectively, In these patients, end-expiratory occlusion increased cardiac index and perfusion index by 6% ± 2% and 11% ± 8%, respectively. In the 12 patients with a negative passive leg raising test, perfusion index did not significantly change during passive leg raising and end-expiratory occlusion. Relative changes in perfusion index and cardiac index observed during all interventions were significantly correlated (r = 0.83). An end-expiratory occlusion-induced relative increase in perfusion index greater than or equal to 2.5% ([perfusion index during end-expiratory occlusion-perfusion index at baseline]/perfusion index at baseline × 100) detected a positive passive leg raising test with an area under the receiver operating characteristic curve of 0.95 ± 0.03. This threshold is larger than the least significant change observed for perfusion index (1.62% ± 0.80%).
CONCLUSIONS: Perfusion index could be used as a reliable surrogate of cardiac index for performing the end-expiratory occlusion test. Confirming previous results, the relative changes in perfusion index also reliably detected a positive passive leg raising test.
Copyright © 2020 by the Society of Critical Care Medicine and Wolters Kluwer Health, Inc. All Rights Reserved.

Entities:  

Year:  2021        PMID: 33332814     DOI: 10.1097/CCM.0000000000004768

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

Review 1.  Prediction of fluid responsiveness. What's new?

Authors:  Xavier Monnet; Rui Shi; Jean-Louis Teboul
Journal:  Ann Intensive Care       Date:  2022-05-28       Impact factor: 10.318

Review 2.  Management of sepsis and septic shock in the emergency department.

Authors:  Francesco Gavelli; Luigi Mario Castello; Gian Carlo Avanzi
Journal:  Intern Emerg Med       Date:  2021-04-22       Impact factor: 3.397

Review 3.  Novel Methods for Predicting Fluid Responsiveness in Critically Ill Patients-A Narrative Review.

Authors:  Jan Horejsek; Jan Kunstyr; Pavel Michalek; Michal Porizka
Journal:  Diagnostics (Basel)       Date:  2022-02-16

Review 4.  How can assessing hemodynamics help to assess volume status?

Authors:  Daniel De Backer; Nadia Aissaoui; Maurizio Cecconi; Michelle S Chew; André Denault; Ludhmila Hajjar; Glenn Hernandez; Antonio Messina; Sheila Nainan Myatra; Marlies Ostermann; Michael R Pinsky; Jean-Louis Teboul; Philippe Vignon; Jean-Louis Vincent; Xavier Monnet
Journal:  Intensive Care Med       Date:  2022-08-10       Impact factor: 41.787

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.