Trabecular Bone Assessment Using Magnetic-Resonance Imaging: A Pilot Study.

Lauren Bohner1,2, Pedro Tortamano2, Norbert Meier3, Felix Gremse4, Johannes Kleinheinz1, Marcel Hanisch1.   

Abstract

The aim of this study was to assess trabecular bone morphology via magnetic-resonance imaging (MRI) using microcomputed tomography (µCT) as the control group. Porcine bone samples were scanned with T1-weighted turbo spin echo sequence imaging, using TR 25 ms, TE 3.5 ms, FOV 100 × 100 × 90, voxel size 0.22 × 0.22 × 0.50 mm, and scan time of 11:18. µCT was used as the control group with 80 kV, 125 mA, and a voxel size of 16 µm. The trabecular bone was segmented on the basis of a reference threshold value and morphological parameters. Bone volume (BV), Bone-volume fraction (BvTv), Bone specific surface (BsBv), trabecular thickness (TbTh), and trabecular separation (TbSp) were evaluated. Paired t-test and Pearson correlation test were performed at p = 0.05. MRI overestimated BV, BvTv, TbTh, and TbSp values. BsBv was the only parameter that was underestimated by MRI. High statistical correlation (r = 0.826; p < 0.05) was found for BV measurements. Within the limitations of this study, MRI overestimated trabecular bone parameters, but with a statistically significant fixed linear offset.

Entities:  

Keywords:  dental implants; magnetic-resonance imaging; microCT

Year:  2020        PMID: 33322479      PMCID: PMC7763832          DOI: 10.3390/ijerph17249282

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


  29 in total

Review 1.  Advanced imaging: Magnetic resonance imaging in implant dentistry.

Authors:  Crawford F Gray; Thomas W Redpath; Francis W Smith; Roger T Staff
Journal:  Clin Oral Implants Res       Date:  2003-02       Impact factor: 5.977

2.  Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment.

Authors:  Ji-Su Oh; Su-Gwan Kim
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2012-03

3.  Predictability of magnetic susceptibility artifacts from metallic orthodontic appliances in magnetic resonance imaging.

Authors:  F Blankenstein; B T Truong; A Thomas; N Thieme; C Zachriat
Journal:  J Orofac Orthop       Date:  2014-11-26       Impact factor: 1.938

4.  Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging.

Authors:  Felix H Blankenstein; Patrick Asbach; Florian Beuer; Johannes Glienke; Stefan Mayer; Christine Zachriat
Journal:  Clin Oral Investig       Date:  2016-03-17       Impact factor: 3.573

5.  Magnetic resonance imaging based computer-guided dental implant surgery-A clinical pilot study.

Authors:  Florian Andreas Probst; Josef Schweiger; Maria Juliane Stumbaum; Dimitrios Karampinos; Egon Burian; Monika Probst
Journal:  Clin Implant Dent Relat Res       Date:  2020-09-09       Impact factor: 3.932

6.  In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique.

Authors:  Dandan Song; Sohaib Shujaat; Ruiting Zhao; Yan Huang; Eman Shaheen; Jeroen Van Dessel; Kaan Orhan; Greetje Vande Velde; Ruxandra Coropciuc; Ruben Pauwels; Constantinus Politis; Reinhilde Jacobs
Journal:  Imaging Sci Dent       Date:  2020-09-16

Review 7.  "Black bone" MRI: a potential alternative to CT when imaging the head and neck: report of eight clinical cases and review of the Oxford experience.

Authors:  K A Eley; S R Watt-Smith; S J Golding
Journal:  Br J Radiol       Date:  2012-11       Impact factor: 3.039

8.  Bone tissue microarchitectural characteristics at dental implant sites part 2: correlation with bone classification and primary stability.

Authors:  Rejane Faria Ribeiro-Rotta; Rubelisa Cândido Gomes de Oliveira; Danilo Rocha Dias; Christina Lindh; Cláudio Rodrigues Leles
Journal:  Clin Oral Implants Res       Date:  2012-10-29       Impact factor: 5.977

9.  Assessment of signal-to-noise ratio and contrast-to-noise ratio in 3 T magnetic resonance imaging in the presence of zirconium, titanium, and titanium-zirconium alloy implants.

Authors:  Husniye Demirturk Kocasarac; Emine Sebnem Kursun-Cakmak; Gulbahar Ustaoglu; Seval Bayrak; Kaan Orhan; Marcel Noujeim
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2019-09-16

10.  Imalytics Preclinical: Interactive Analysis of Biomedical Volume Data.

Authors:  Felix Gremse; Marius Stärk; Josef Ehling; Jan Robert Menzel; Twan Lammers; Fabian Kiessling
Journal:  Theranostics       Date:  2016-01-01       Impact factor: 11.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.