BACKGROUND: Transcatheter aortic valve replacement (TAVR) has been shown to be a good alternative to surgery for treating severe symptomatic aortic stenosis (AS) across the whole range of surgical risk patients. Whereas most periprocedural TAVR complications have significantly decreased over time, conduction disturbances remain high. Approaches to decrease this shortcoming are under continuous investigation. METHODS: We conducted a systematic review focusing on modifiable factors impacting post-TAVR conduction disturbances, such as balloon aortic valvuloplasty (BAV), type of new-generation transcatheter valve and implantation depth (ID). Search strategies were based on the best available evidence from each study. Primary endpoints were post-TAVR need of permanent pacemaker implantation (PPI) and new onset left bundle branch block (NOLBBB). RESULTS: Data from 35 studies with a total of 29,982 patients were analyzed. BAV did not negatively impact PPI rates after TAVR. In propensity-matched and randomized trials, the Evolut R valve was associated with higher rates of PPI compared to the Sapien 3 valve (25% vs. 19.2% in propensity-matched studies; 22.9% vs. 19% in a randomized trial). The Acurate Neo valve was associated with the lowest PPI rate in observational studies (10.4%), but a PPI rate similar to Sapien 3 was reported in a randomized trial (10% vs. 9%). The Portico valve system was associated with a higher PPI risk (PPI rate of 21.9% and 27.7% in propensity-matched and randomized studies, respectively). ID and its relation with the membranous septum (MS) length predicted post-TAVR conduction disturbances, particularly with Evolut R and Sapien 3 valves. CONCLUSIONS: Pre-TAVR BAV did not increase the risk of conduction disturbances post-TAVR. Among the new-generation transcatheter valve systems, Sapien 3 and Acurate Neo valves were associated with the lowest PPI rates followed by the Evolut and Portico valves. A deeper valve implantation and a shorter MS length determined an increased risk of conduction disturbances post-TAVR. 2020 Annals of Cardiothoracic Surgery. All rights reserved.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) has been shown to be a good alternative to surgery for treating severe symptomatic aortic stenosis (AS) across the whole range of surgical risk patients. Whereas most periprocedural TAVR complications have significantly decreased over time, conduction disturbances remain high. Approaches to decrease this shortcoming are under continuous investigation. METHODS: We conducted a systematic review focusing on modifiable factors impacting post-TAVR conduction disturbances, such as balloon aortic valvuloplasty (BAV), type of new-generation transcatheter valve and implantation depth (ID). Search strategies were based on the best available evidence from each study. Primary endpoints were post-TAVR need of permanent pacemaker implantation (PPI) and new onset left bundle branch block (NOLBBB). RESULTS: Data from 35 studies with a total of 29,982 patients were analyzed. BAV did not negatively impact PPI rates after TAVR. In propensity-matched and randomized trials, the Evolut R valve was associated with higher rates of PPI compared to the Sapien 3 valve (25% vs. 19.2% in propensity-matched studies; 22.9% vs. 19% in a randomized trial). The Acurate Neo valve was associated with the lowest PPI rate in observational studies (10.4%), but a PPI rate similar to Sapien 3 was reported in a randomized trial (10% vs. 9%). The Portico valve system was associated with a higher PPI risk (PPI rate of 21.9% and 27.7% in propensity-matched and randomized studies, respectively). ID and its relation with the membranous septum (MS) length predicted post-TAVR conduction disturbances, particularly with Evolut R and Sapien 3 valves. CONCLUSIONS: Pre-TAVR BAV did not increase the risk of conduction disturbances post-TAVR. Among the new-generation transcatheter valve systems, Sapien 3 and Acurate Neo valves were associated with the lowest PPI rates followed by the Evolut and Portico valves. A deeper valve implantation and a shorter MS length determined an increased risk of conduction disturbances post-TAVR. 2020 Annals of Cardiothoracic Surgery. All rights reserved.
Authors: Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon Journal: N Engl J Med Date: 2019-03-16 Impact factor: 91.245
Authors: Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith Journal: N Engl J Med Date: 2019-03-16 Impact factor: 91.245
Authors: Hasan Jilaihawi; Zhengang Zhao; Run Du; Cezar Staniloae; Muhamed Saric; Peter J Neuburger; Michael Querijero; Alan Vainrib; Kazuhiro Hisamoto; Homam Ibrahim; Tara Collins; Emily Clark; Illya Pushkar; Daniel Bamira; Ricardo Benenstein; Afnan Tariq; Mathew Williams Journal: JACC Cardiovasc Interv Date: 2019-08-28 Impact factor: 11.195
Authors: Victor Mauri; Andreas Reimann; Daniel Stern; Maximilian Scherner; Elmar Kuhn; Volker Rudolph; Stephan Rosenkranz; Kaveh Eghbalzadeh; Kai Friedrichs; Thorsten Wahlers; Stephan Baldus; Navid Madershahian; Tanja K Rudolph Journal: JACC Cardiovasc Interv Date: 2016-11-14 Impact factor: 11.195
Authors: Silvia Mas-Peiro; Philipp Christian Seppelt; Helge Weiler; Gina-Lisa Mohr; Nestoras Papadopoulos; Thomas Walther; Andreas M Zeiher; Stephan Fichtlscherer; Mariuca Vasa-Nicotera Journal: J Invasive Cardiol Date: 2019-07 Impact factor: 2.022
Authors: Eduardo Enríquez-Rodríguez; Ignacio J Amat-Santos; Pilar Jiménez-Quevedo; Irene Martín-Morquecho; Gabriela Tirado-Conte; María José Pérez-Vizcayno; José Juan Gómez de Diego; Roman Arnold; Andrés Aldazábal; Paol Rojas; Alberto de Agustín; María Del Trigo; Hipólito Gutiérrez; José A San Román; Carlos Macaya; Luis Nombela-Franco Journal: Rev Esp Cardiol (Engl Ed) Date: 2017-11-28
Authors: Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb Journal: N Engl J Med Date: 2016-04-02 Impact factor: 91.245
Authors: Serkan Aslan; Aysel Türkvatan; Çağdaş Topel; Ahmet Güner; Ali Rıza Demir; Serkan Kahraman; Ömer Çelik; Mehmet Ertürk Journal: Anatol J Cardiol Date: 2022-07 Impact factor: 1.475