Literature DB >> 33312901

Overcoming the transcatheter aortic valve replacement Achilles heel: conduction abnormalities-a systematic review.

Alberto Alperi1, Guillem Muntané-Carol1, Afonso B Freitas-Ferraz1, Lucia Junquera1, David Del Val1, Laurent Faroux1, François Philippon1, Josep Rodés-Cabau1.   

Abstract

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has been shown to be a good alternative to surgery for treating severe symptomatic aortic stenosis (AS) across the whole range of surgical risk patients. Whereas most periprocedural TAVR complications have significantly decreased over time, conduction disturbances remain high. Approaches to decrease this shortcoming are under continuous investigation.
METHODS: We conducted a systematic review focusing on modifiable factors impacting post-TAVR conduction disturbances, such as balloon aortic valvuloplasty (BAV), type of new-generation transcatheter valve and implantation depth (ID). Search strategies were based on the best available evidence from each study. Primary endpoints were post-TAVR need of permanent pacemaker implantation (PPI) and new onset left bundle branch block (NOLBBB).
RESULTS: Data from 35 studies with a total of 29,982 patients were analyzed. BAV did not negatively impact PPI rates after TAVR. In propensity-matched and randomized trials, the Evolut R valve was associated with higher rates of PPI compared to the Sapien 3 valve (25% vs. 19.2% in propensity-matched studies; 22.9% vs. 19% in a randomized trial). The Acurate Neo valve was associated with the lowest PPI rate in observational studies (10.4%), but a PPI rate similar to Sapien 3 was reported in a randomized trial (10% vs. 9%). The Portico valve system was associated with a higher PPI risk (PPI rate of 21.9% and 27.7% in propensity-matched and randomized studies, respectively). ID and its relation with the membranous septum (MS) length predicted post-TAVR conduction disturbances, particularly with Evolut R and Sapien 3 valves.
CONCLUSIONS: Pre-TAVR BAV did not increase the risk of conduction disturbances post-TAVR. Among the new-generation transcatheter valve systems, Sapien 3 and Acurate Neo valves were associated with the lowest PPI rates followed by the Evolut and Portico valves. A deeper valve implantation and a shorter MS length determined an increased risk of conduction disturbances post-TAVR. 2020 Annals of Cardiothoracic Surgery. All rights reserved.

Entities:  

Keywords:  Transcatheter aortic valve replacement (TAVR); conduction disturbances; left bundle branch block; pacemaker

Year:  2020        PMID: 33312901      PMCID: PMC7724069          DOI: 10.21037/acs-2020-av-40

Source DB:  PubMed          Journal:  Ann Cardiothorac Surg        ISSN: 2225-319X


  45 in total

1.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

2.  Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

Authors:  Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

3.  Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement.

Authors:  Hasan Jilaihawi; Zhengang Zhao; Run Du; Cezar Staniloae; Muhamed Saric; Peter J Neuburger; Michael Querijero; Alan Vainrib; Kazuhiro Hisamoto; Homam Ibrahim; Tara Collins; Emily Clark; Illya Pushkar; Daniel Bamira; Ricardo Benenstein; Afnan Tariq; Mathew Williams
Journal:  JACC Cardiovasc Interv       Date:  2019-08-28       Impact factor: 11.195

4.  Sapien 3 Transcatheter Aortic Valve Implantation With Moderate or Without Predilation.

Authors:  Yigal Abramowitz; Hasan Jilaihawi; Tarun Chakravarty; Yoshio Maeno; Hiroyuki Kawamori; Yoshio Kazuno; Geeteshwar Mangat; Tanya Rami; Zev Allison; David Anderson; Larry Chan; Wen Cheng; Raj R Makkar
Journal:  J Invasive Cardiol       Date:  2016-10       Impact factor: 2.022

5.  Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial.

Authors:  Holger Thiele; Thomas Kurz; Hans-Josef Feistritzer; Georg Stachel; Philipp Hartung; Ingo Eitel; Christoph Marquetand; Holger Nef; Oliver Doerr; Alexander Lauten; Ulf Landmesser; Mohamed Abdel-Wahab; Marcus Sandri; David Holzhey; Michael Borger; Hüseyin Ince; Alper Öner; Roza Meyer-Saraei; Harm Wienbergen; Andreas Fach; Norbert Frey; Inke R König; Reinhard Vonthein; Yvonne Rückert; Anne-Kathrin Funkat; Suzanne de Waha-Thiele; Steffen Desch
Journal:  Eur Heart J       Date:  2020-05-21       Impact factor: 29.983

6.  Very low pacemaker rate following ACURATE neo transcatheter heart valve implantation.

Authors:  Stefan Toggweiler; Henrik Nissen; Brynjolfur Mogensen; Florim Cuculi; Christian Fallesen; Karsten Tange Veien; Miriam Brinkert; Richard Kobza; Andreas Rück
Journal:  EuroIntervention       Date:  2017-12-20       Impact factor: 6.534

7.  Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.

Authors:  Victor Mauri; Andreas Reimann; Daniel Stern; Maximilian Scherner; Elmar Kuhn; Volker Rudolph; Stephan Rosenkranz; Kaveh Eghbalzadeh; Kai Friedrichs; Thorsten Wahlers; Stephan Baldus; Navid Madershahian; Tanja K Rudolph
Journal:  JACC Cardiovasc Interv       Date:  2016-11-14       Impact factor: 11.195

8.  A Direct Comparison of Self-Expandable Portico Versus Balloon-Expandable Sapien 3 Devices for Transcatheter Aortic Valve Replacement: A Case-Matched Cohort Study.

Authors:  Silvia Mas-Peiro; Philipp Christian Seppelt; Helge Weiler; Gina-Lisa Mohr; Nestoras Papadopoulos; Thomas Walther; Andreas M Zeiher; Stephan Fichtlscherer; Mariuca Vasa-Nicotera
Journal:  J Invasive Cardiol       Date:  2019-07       Impact factor: 2.022

9.  Comparison of the Hemodynamic Performance of the Balloon-expandable SAPIEN 3 Versus Self-expandable Evolut R Transcatheter Valve: A Case-matched Study.

Authors:  Eduardo Enríquez-Rodríguez; Ignacio J Amat-Santos; Pilar Jiménez-Quevedo; Irene Martín-Morquecho; Gabriela Tirado-Conte; María José Pérez-Vizcayno; José Juan Gómez de Diego; Roman Arnold; Andrés Aldazábal; Paol Rojas; Alberto de Agustín; María Del Trigo; Hipólito Gutiérrez; José A San Román; Carlos Macaya; Luis Nombela-Franco
Journal:  Rev Esp Cardiol (Engl Ed)       Date:  2017-11-28

10.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

Authors:  Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb
Journal:  N Engl J Med       Date:  2016-04-02       Impact factor: 91.245

View more
  4 in total

1.  Structured Allocation of Transcatheter Aortic Valve Replacement Patients during Coronavirus Disease 2019 Pandemic: Impact on Patient Selection and Clinical Results.

Authors:  Nora Berisha; Kathrin Klein; Verena Veulemans; Oliver Maier; Kerstin Piayda; Stephan Binnebößel; Shazia Afzal; Amin Polzin; Ralf Westenfeld; Patrick Horn; Christian Jung; Malte Kelm; Christine Quast; Tobias Zeus
Journal:  J Cardiovasc Dev Dis       Date:  2022-06-10

2.  The Predictors of Conduction Disturbances Following Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve: A Multicenter Study.

Authors:  Yuchao Guo; Dao Zhou; Mengqiu Dang; Yuxing He; Shenwei Zhang; Jun Fang; Shili Wu; Qiong Huang; Lianglong Chen; Yiqiang Yuan; Jiaqi Fan; Hasan Jilaihawi; Xianbao Liu; Jian'an Wang
Journal:  Front Cardiovasc Med       Date:  2021-11-29

3.  Preprocedural and procedural variables that predict new-onset conduction disturbances after transcatheter aortic valve replacement.

Authors:  Wongsaput Boonyakiatwattana; Adisak Maneesai; Vithaya Chaithiraphan; Decho Jakrapanichakul; Pranya Sakiyalak; Narathip Chunhamaneewat; Worawong Slisatkorn; Chunhakasem Chotinaiwattarakul; Rungtiwa Pongakasira; Nattawut Wongpraparut
Journal:  BMC Cardiovasc Disord       Date:  2022-03-31       Impact factor: 2.298

4.  Structural Changesofthe Right Fibrous Trigone as a Risk Factor for Conduction Disturbance After Transcatheter Aortic Valve Implantation.

Authors:  Serkan Aslan; Aysel Türkvatan; Çağdaş Topel; Ahmet Güner; Ali Rıza Demir; Serkan Kahraman; Ömer Çelik; Mehmet Ertürk
Journal:  Anatol J Cardiol       Date:  2022-07       Impact factor: 1.475

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.