| Literature DB >> 33312823 |
Vatche Melkonian1, Tess Huy2, Chintalapati R Varma1, Mustafa Nazzal1, Henry B Randall1, Minh-Tri J Nguyen3.
Abstract
Introduction Resident inexperience during time-sensitive vascular anastomoses of a kidney transplant can negatively impact outcomes. In light of this, we created a low-cost bench-top kidney transplant surgery simulator to help residents practice vascular anastomoses. Methods We searched for inexpensive materials to design an iliac fossa and kidney allograft. Eighteen residents with real-life kidney transplant experience trialed the simulator and scored its fidelity and educational utility on a 0-100 visual analog scale (VAS) survey. Results A 35.9 x 19.4 x 12.4 cm plastic box mimicked the iliac fossa. Hooks attached to the box's sidewall held under tension 1.27 and 0.64 cm diameter Penrose drains to replicate the external iliac vein and artery. A modified kidney-shaped stress ball with 1.27 x 4, 0.64 x 4, and 0.64 x 15 cm Penrose drains replicated a kidney allograft with its vein, artery, and ureter, respectively. Residents performed and assisted in vascular anastomoses on the simulator. The iliac fossa and allograft cost $20.20 and each practice run cost $7.20. Residents thought that the simulator was less difficult than real-life procedure, had acceptable fidelity levels, and they highly rated its educational utility. Conclusion Our novel low-cost bench-top kidney transplant surgery simulator focusing on vascular anastomoses received positive educational feedback from residents.Entities:
Keywords: kidney transplantation; medical education; residency; simulation training; surgical anastomosis
Year: 2020 PMID: 33312823 PMCID: PMC7727770 DOI: 10.7759/cureus.11427
Source DB: PubMed Journal: Cureus ISSN: 2168-8184
Figure 1The 10-question feedback survey on the fidelity and educational utility of the novel bench-top kidney transplant surgery simulator
The answers were recorded and scored using a 0-100 visual analog scale
PGY: post-graduate year
Figure 2Bench-top kidney transplant surgery simulator design
The images show the design replicating A) the recipient right iliac fossa and B) a left kidney transplant allograft
Video 1Brief demonstration of the bench-top kidney transplant surgery simulator
Figure 3Two residents work together on the bench-top kidney transplant surgery simulator
The images show residents performing the A) venous and B) arterial vascular anastomoses operative steps of a real-life kidney transplant. C) An alternative technique to the venous anastomosis is demonstrated in which the back wall is performed from inside the lumen
Cost of the bench-top kidney transplant surgery simulator
aSuture prices reflect the purchase of expired products from online vendors; bsurgical instruments and accessories were purchased from online vendors but can alternatively be borrowed for free from the operating room
| Quantity | Cost/unit ($) | Total cost ($) | |
| Bench-top kidney transplant surgery simulator materials | |||
| Reusables | |||
| Plastic box | 1 | 5.00 | 5.00 |
| Plastic mini-hooks | 4 | 1.00 | 4.00 |
| Kidney stress ball | 1 | 10.00 | 10.00 |
| Disposables | |||
| Penrose drain 1.27 x 45.72 cm | 1 | 0.60 | 0.60 |
| Penrose drain 0.64 x 45.72 cm | 1 | 0.60 | 0.60 |
| Total | 8 | 20.20 | |
| Sutures | |||
| Disposables | |||
| 5-0 Prolene suture with double-armed C1 needle (91 cm) | 4 | 1.00 | 4.00 |
| 6-0 Prolene suture with double-armed C1 needle (76 cm) | 2 | 1.00 | 2.00 |
| Total | 6 | 6.00a | |
| Surgical instruments and accessories | |||
| Reusables | |||
| Castroviejo straight needle holder (17.78 cm) | 1 | 10.00 | 10.00 |
| Lambert-Kay vascular clamp (21.59 cm) | 1 | 20.00 | 20.00 |
| DeBakey angled vascular clamp (12.7 cm) | 2 | 10.00 | 20.00 |
| Gerald tissue forceps (20.32 cm) | 3 | 5.00 | 15.00 |
| Metzenbaum curved scissors (17.78 cm) | 1 | 5.00 | 5.00 |
| Potts 45° Scissors (19.05 cm) | 1 | 5.00 | 5.00 |
| Hemostat curved clamp (12.7 cm) | 5 | 5.00 | 25.00 |
| Rubber-shod clamp cover | 4 | 1.00 | 4.00 |
| Vessel loop | 1 | 3.00 | 3.00 |
| Scalpel with 11 blade | 1 | 1.00 | 1.00 |
| Gauze sponge (10 x 10 cm) | 1 | 0.10 | 0.10 |
| Total | 21 | 108.10b |
Figure 4Mean 0-100 visual analog scale scores provided by PGY 1-5 general surgery residents for survey questions on the fidelity and educational utility of the novel bench-top kidney transplant surgery simulator
Comparisons of kidney transplant case log number and mean visual analog scale score for survey questions regarding the bench-top kidney transplant surgery simulator between PGY 1-3 and PGY 4-5 residents
aMann-Whitney U test
PGY: post-graduate year
| Survey questions | Mean score | P-valuea | |
| PGY 1-3 (n = 10) | PGY 4-5 (n = 8) | ||
| Case log number | 2 ± 0 | 18 ± 4 | <0.01 |
| 1. Difficulty level of the model | 25 ± 6 | 37 ± 5 | 0.37 |
| 2. Realism of arterial and venous anastomoses | 70 ± 5 | 70 ± 8 | 0.86 |
| 3. Practice needle control/precision | 89 ± 5 | 93 ± 2 | 0.82 |
| 4. Improve suturing speed | 87 ± 5 | 94 ± 2 | 0.52 |
| 5. Practice knot tying/handling small sutures | 91 ± 3 | 86 ± 8 | 1.00 |
| 6. Learn operative steps | 79 ± 8 | 88 ± 3 | 0.68 |
| 7. Learn to assist | 87 ± 5 | 82 ± 6 | 0.50 |
| 8. Adaptation to magnifying surgical loupes | 81 ± 8 | 83 ± 9 | 0.96 |
| 9. Access to model before the first kidney transplant | 96 ± 2 | 98 ± 2 | 0.73 |
| 10. Inclusion of model in transplant curriculum | 91 ± 4 | 99 ± 1 | 0.16 |