| Literature DB >> 33304578 |
Dereje Zewdu1, Fissiha Fentie2, Abdisa Aga3, Assefa Hika4, Diriba Teshome5.
Abstract
BACKGROUND: Caudal block is a common regional technique performed for infra umbilical surgery in pediatrics. Its limited duration of analgesia remains a gap in routine clinical practice. This study aimed to assess the analgesic effectiveness of caudal block with rectal diclofenac or rectal paracetamol among pediatric patients who underwent infra umbilical surgery.Entities:
Keywords: Caudal block; Diclofenac; Paracetamol; Postoperative analgesia
Year: 2020 PMID: 33304578 PMCID: PMC7718114 DOI: 10.1016/j.amsu.2020.11.071
Source DB: PubMed Journal: Ann Med Surg (Lond) ISSN: 2049-0801
Demographic and perioperative characteristics of the study participants.
| Variables | Group CA | Group CP | Group CD | P-value |
|---|---|---|---|---|
| Age (year) | 4.96 ± 2.3 | 4.63 ± 2.25 | 4.46 ± 2.26 | 0.97 |
| Gender (M/F) | 21/9 | 19/11 | 23/7 | 0.530 |
| ASA I/II | 26/4 | 27/3 | 25/5 | 0.749 |
| Weight (kg) | 13.96 ± 2.63 | 13.46 ± 2.69 | 14.1 ± 2.34 | 0.769 |
| Baseline Heart Rate | 129 ± 10.49 | 131 ± 11.38 | 133.5 ± 11.93 | 0.827 |
| Baseline MAP | 60.17 ± 5.37 | 63.96 ± 3.4 | 62.97 ± 4.13 | 0.231 |
| Atropine pre medication | 16/14 | 18/12 | 20/10 | 0.574 |
| Induction agent | 12/26 | 15/15 | 14/16 | 0.731 |
| Maintenance agent | 19/11 | 19/11 | 18/12 | 0.954 |
| Surgery duration (min) | 105.16 ± 18.91 | 101 ± 19 | 102.3 ± 17.86 | 0.598 |
| Anesthesia duration (min) | 119.66 ± 17.66 | 116.5 ± 8.34 | 113.83 ± 15.46 | 0.573 |
| Surgical incision length | 15 (14–16) | 15 (15–17) | 14 (15–17) | 0.765 |
Values that were expressed by Mean ± SD
Values that were expressed by number/proportion.
Comparison of hemodynamic response between the groups.
| Hemodynamic Response | Group CA | Group CP | Group CD | P-value | |
|---|---|---|---|---|---|
| Before incision | PR | 121.7 ± 8.38 62.93 ± 3.18 | 122.56 ± 10.3664.4 ± 3.81 | 124.83 ± 8.09 64.26 ± 3.31 | 0.384 0.196 |
| After incision | PR | 130.16 ± 7.6 65.93 ± 3.17 | 166.4 ± 3.89 6.26 ± 8.89 | 129.5 ± 9.25 65.36 ± 3.20 | 0.264 0.509 |
| Arrival at PACU | PR | 135.23 ± 7.75 66.7 ± 2.66 | 131.66 ± 8.6367.06 ± 3.18 | 132.7 ± 9.41 | 0.509 0.350 |
| At 20 min PACU | PR | 126.43 ± 7.66 65.26 ± 2.75 | 124.66 ± 8.6365.6 ± 3.47 | 123.8 ± 9.73 65.18 ± 3.04 | 0.494 0.516 |
| At 40 min PACU | PR | 121.46 ± 7.1 64.43 ± 2.71 | 121.5 ± 8.53 64.86 ± 2.94 | 119.13 ± 9.49 64.03 ± 2.55 | 0.498 0.503 |
| At 60 min PACU | PR | 123.06 ± 9.43 64.1 ± 2.36 | 119.5 ± 6.98 64.53 ± 2.88 | 116.06 ± 9.49 63.7 ± 2.45 | 0.197 0.460 |
N·B PACU: Post-Anesthesia Care Unit.
Fig. 1Comparison of postoperative pain score (NRS/FLACC score).
Fig. 2Incidence of Postoperative nausea and vomiting between groups.