Sebastian Serong1, Moritz Schutzbach2, Ivica Zovko2, Marcus Jäger3, Stefan Landgraeber4, Marcel Haversath2.
Abstract
BACKGROUND: The recently described 'critical trochanter angle' (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability. It is hypothesized that both analyses justify the clinical use of the CTA.Entities:
Keywords: Critical trochanter angle; Interobserver; Intraobserver; Reliability; Stem alignment; Total hip arthroplasty
Year: 2020 PMID: 33302979 PMCID: PMC7731484 DOI: 10.1186/s40001-020-00469-4
Source DB: PubMed Journal: Eur J Med Res ISSN: 0949-2321 Impact factor: 2.175
Fig. 1Flowchart demonstrating the inclusion/exclusion of radiographs to obtain the target quantity of n = 100
Fig. 2Measurement of the ‘critical trochanter angle’ (CTA) as described by Haversath et al. [11]
Intraobserver variation of observers 1–4 between the first and second measurement of the ‘critical trochanter angle’ (CTA)
| Intraobserver variation | |||||
|---|---|---|---|---|---|
| Observer | Subjects | Difference mean (°) (SD) | 95% limits of agreement (°) | ICC (95% CI) | |
| Observer 1 | 100 | − 0.17 (1.63) | − 3.35–3.02 | 0.31 | 0.99 (0.98–0.99) |
| Observer 2 | 100 | 0.08 (1.97) | − 3.79–3.95 | 0.68 | 0.97 (0.96–0.98) |
| Observer 3 | 100 | − 0.25 (2.28) | − 4.72–4.22 | 0.27 | 0.96 (0.93–0.97) |
| Observer 4 | 100 | − 0.47 (3.69) | − 7.70–6.77 | 0.21 | 0.92 (0.88–0.94) |
Fig. 3Intraobserver variation of the ‘critical trochanter angle’ (CTA) for observer 1; solid line—mean value of measurements, dotted lines—95% limits of agreement above and below the mean value
Fig. 4Intraobserver variation of the ‘critical trochanter angle’ (CTA) for observer 2 (for explanations see Fig. 2)
Fig. 5Intraobserver variation of the ‘critical trochanter angle’ (CTA) for observer 3 (for explanations see Fig. 2)
Fig. 6Intraobserver variation of the ‘critical trochanter angle’ (CTA) for observer 4 (for explanations see Fig. 2)
Interobserver correlation of the ‘critical trochanter angle (CTA) for both measuring sequences
| Interobserver correlation | ||||
|---|---|---|---|---|
| Measuring sequence | Subjects | Mean CTA (°) | ICC (95% CI) | |
| Observer 1 | 100 | 25.06 | 0.83 (0.67–0.90) | |
| Observer 2 | 100 | 20.34 | ||
| Observer 3 | 100 | 19.15 | ||
| Observer 4 | 100 | 17.76 | ||
| Observer 1 | 100 | 25.23 | 0.85 (0.68–0.92) | |
| Observer 2 | 100 | 20.26 | ||
| Observer 3 | 100 | 19.40 | ||
| Observer 4 | 100 | 18.22 | ||