Literature DB >> 33295293

ISO/IEEE 11073 Treadmill Interoperability Framework and its Test Method: Design and Implementation.

Zhi Yong Huang1, Yujie Wang1, Linling Wang2.   

Abstract

BACKGROUND: Regular physical activity is proven to help prevent and treat noncommunicable diseases such as heart disease, stroke, diabetes, and breast and colon cancer. The exercise data generated by health and fitness devices (eg, treadmill, exercise bike) are very important for health management service providers to develop personalized training programs. However, at present, there is little research on a unified interoperability framework in the health and fitness domain, and there are not many solutions; besides, the privatized treadmill data transmission scheme is not conducive to data integration and analysis.
OBJECTIVE: This article will expand the IEEE 11073-PHD standard protocol family, develop standards for health and fitness device (using treadmill as an example) based on the latest version of the 11073-20601 optimized exchange protocol, and design protocol standards compliance testing process and inspection software, which can automatically detect whether the instantiated object of the treadmill meets the standard.
METHODS: The study includes the following steps: (1) Map the data transmitted by the treadmill to the 11073-PHD objects; (2) Construct a programming language structure corresponding to the 11073-PHD application protocol data unit (APDU) to complete the coding and decoding part of the test software; and (3) Transmit the instantiated simulated treadmill data to the gateway test software through transmission control protocol for standard compliance testing.
RESULTS: According to the characteristics of the treadmill, a data exchange framework conforming to 11073-PHD is constructed, and a corresponding testing framework is developed; a treadmill agent simulation is implemented, and the interoperability test is performed. Through the designed testing process, the corresponding testing software was developed to complete the standard compliance testing of the treadmill.
CONCLUSIONS: The extended research of IEEE 11073-PHD in the field of health and fitness provides a potential new idea for the data transmission framework of sports equipment such as treadmills, which may also provide some help for the development of sports health equipment interoperability standards. ©Zhi Yong Huang, Yujie Wang, Linling Wang. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 09.12.2020.

Entities:  

Keywords:  ISO/IEEE 11073-PHD; sports health data; standard frame model; test standard; treadmill

Year:  2020        PMID: 33295293      PMCID: PMC7758169          DOI: 10.2196/22000

Source DB:  PubMed          Journal:  JMIR Med Inform


  10 in total

1.  Estimation of VO2max from the ratio between HRmax and HRrest--the Heart Rate Ratio Method.

Authors:  Niels Uth; Henrik Sørensen; Kristian Overgaard; Preben K Pedersen
Journal:  Eur J Appl Physiol       Date:  2003-11-18       Impact factor: 3.078

2.  Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

Authors:  Jesús D Trigo; Franco Chiarugi; Alvaro Alesanco; Miguel Martínez-Espronceda; Luis Serrano; Catherine E Chronaki; Javier Escayola; Ignacio Martínez; José García
Journal:  IEEE Trans Inf Technol Biomed       Date:  2010-08-09

3.  Home healthcare settop-box for senior chronic care using ISO/IEEE 11073 PHD standard.

Authors:  Joon-Ho Lim; Chanyong Park; Soo-Jun Park
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

4.  Standard-compliant real-time transmission of ECGs: harmonization of ISO/IEEE 11073-PHD and SCP-ECG.

Authors:  Jesús D Trigo; Franco Chiarugi; Alvaro Alesanco; Miguel Martínez-Espronceda; Catherine E Chronaki; Javier Escayola; Ignacio Martínez; José García
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

5.  Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

Authors:  Mustafa Yuksel; Asuman Dogac
Journal:  IEEE Trans Inf Technol Biomed       Date:  2011-05-10

6.  Heart rate response during underwater treadmill training in adults with incomplete spinal cord injury.

Authors:  Sandra L Stevens; Don W Morgan
Journal:  Top Spinal Cord Inj Rehabil       Date:  2015

7.  Device interoperability and authentication for telemedical appliance based on the ISO/IEEE 11073 Personal Health Device (PHD) Standards.

Authors:  Luther Paul R Caranguian; Susan Pancho-Festin; Luis G Sison
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

8.  Advanced portable remote monitoring system for the regulation of treadmill running exercises.

Authors:  Tuan Nghia Nguyen; Steven Su; Branko Celler; Hung Nguyen
Journal:  Artif Intell Med       Date:  2014-05-23       Impact factor: 5.326

9.  Determining target heart rate for exercising in a cardiac rehabilitation program: a retrospective study.

Authors:  Lonnie A Sebastian; Sara Reeder; Mark Williams
Journal:  J Cardiovasc Nurs       Date:  2015 Mar-Apr       Impact factor: 2.083

10.  Metadata Correction: Clinical Validation of Heart Rate Apps: Mixed-Methods Evaluation Study.

Authors:  Thijs Vandenberk; Jelle Stans; Christophe Mortelmans; Ruth Van Haelst; Gertjan Van Schelvergem; Caroline Pelckmans; Christophe Jp Smeets; Dorien Lanssens; Hélène De Cannière; Valerie Storms; Inge M Thijs; Bert Vaes; Pieter M Vandervoort
Journal:  JMIR Mhealth Uhealth       Date:  2018-03-14       Impact factor: 4.773

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.