Literature DB >> 23366130

Device interoperability and authentication for telemedical appliance based on the ISO/IEEE 11073 Personal Health Device (PHD) Standards.

Luther Paul R Caranguian1, Susan Pancho-Festin, Luis G Sison.   

Abstract

In this study, we focused on the interoperability and authentication of medical devices in the context of telemedical systems. A recent standard called the ISO/IEEE 11073 Personal Health Device (X73-PHD) Standards addresses the device interoperability problem by defining common protocols for agent (medical device) and manager (appliance) interface. The X73-PHD standard however has not addressed security and authentication of medical devices which is important in establishing integrity of a telemedical system. We have designed and implemented a security policy within the X73-PHD standards. The policy will enable device authentication using Asymmetric-Key Cryptography and the RSA algorithm as the digital signature scheme. We used two approaches for performing the digital signatures: direct software implementation and use of embedded security modules (ESM). The two approaches were evaluated and compared in terms of execution time and memory requirement. For the standard 2048-bit RSA, ESM calculates digital signatures only 12% of the total time for the direct implementation. Moreover, analysis shows that ESM offers more security advantage such as secure storage of keys compared to using direct implementation. Interoperability with other systems was verified by testing the system with LNI Healthlink, a manager software that implements the X73-PHD standard. Lastly, security analysis was done and the system's response to common attacks on authentication systems was analyzed and several measures were implemented to protect the system against them.

Entities:  

Mesh:

Year:  2012        PMID: 23366130     DOI: 10.1109/EMBC.2012.6346169

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

1.  ISO/IEEE 11073 Treadmill Interoperability Framework and its Test Method: Design and Implementation.

Authors:  Zhi Yong Huang; Yujie Wang; Linling Wang
Journal:  JMIR Med Inform       Date:  2020-12-09

2.  Design and implementation of a prototype with a standardized interface for transducers in ambient assisted living.

Authors:  Enrique Dorronzoro; Isabel Gómez; Ana Verónica Medina; José Antonio Gómez
Journal:  Sensors (Basel)       Date:  2015-01-29       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.