Articular Noise After THA Using Delta CoC Bearings Has Little Impact on Quality of Life.

Jean-Christophe Chatelet1, Michel-Henri Fessy2, Mo Saffarini3, Alain Machenaud4, Laurent Jacquot4.   

Abstract

BACKGROUND: To report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL).
METHODS: From a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors.
RESULTS: The 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030).
CONCLUSION: Of 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  THA; ceramic on ceramic; noise; squeaking; survival; total hip arthroplasty

Year:  2020        PMID: 33293173     DOI: 10.1016/j.arth.2020.11.012

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

Review 1.  Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts.

Authors:  Pascal-André Vendittoli; Sagi Martinov; Mina Wahba Morcos; Sivan Sivaloganathan; William G Blakeney
Journal:  J Clin Med       Date:  2022-03-30       Impact factor: 4.241

2.  Short uncemented femoral component for hip revision: prognosis and risk factors associated with failure.

Authors:  Zeming Liu; Bo Liu; Bingshi Zhang; Wenhui Ma; Tao Wu; Jia Huo; Sikai Liu; Yongtai Han
Journal:  BMC Surg       Date:  2021-04-13       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.