Literature DB >> 33289009

Sensitive, Rapid, Low-Cost, and Multiplexed COVID-19 Monitoring by the Wireless Telemedicine Platform.

Zhongyang Zhang1,2, Zhongmin Tang2, Nika Farokhzad3, Tianfeng Chen1, Wei Tao2.   

Abstract

To prevent the more severe spread of COVID-19 infections, sensitive, rapid, low-cost, and multiplexed detection is critical. Recently, Gao et al. reported a laser-engraved graphene-based wireless device to monitor multiple biomarkers from human biofluids, allowing for high-frequency self-testing of COVID-19 with high accuracy and low cost.
© 2020 Elsevier Inc.

Entities:  

Year:  2020        PMID: 33289009      PMCID: PMC7709617          DOI: 10.1016/j.matt.2020.11.001

Source DB:  PubMed          Journal:  Matter        ISSN: 2590-2385


Main Text

According to the data collected by the WHO, SARS-CoV-2 induced a higher case fatality rate (around 3.3%) than that of the previous influenza pandemics in 1918 and 1957, and its spread rate is even 40-fold higher than that of SARS-CoV. Until now, the collaboration of multidisciplinary scientists has promoted coordinated treatment and vaccination strategies, but risks associated with COVID-19 are not mitigated. To achieve a safe reopening of society, the economy, and college campuses, accurate, rapid, and low-cost detection strategies are critical to hinder the transmission of SARS-CoV-2. , While it is readily clear that symptomatic individuals require identification in order to reduce community spread, asymptomatic persons should also be monitored. Real-time polymerase chain reaction (RT-PCR) on the virus nucleic acid is regarded as the current golden standard testing approach, though its drawbacks include expensive equipment, the need for professional technicians, being time-consuming, and as-known false negatives. These drawbacks restrict its potential use in daily self-testing. , Besides, determinations of an individual’s serologic status regarding antibodies specific to the virus antigens and circulating inflammatory biomarkers are equally important on identifying convalescent persons and evaluating COVID-19 severities. Therefore, a highly sensitive, rapid, low-cost, and multiplexed COVID-19 test is still highly demanded. Emerging two-dimensional (2D) monoelemental materials (Xenes) have shown a great potential in multiple biomedical applications including monitoring and detection of various diseases. As one of the most representative Xenes, the use of graphene in this specific field is very attractive. For example, in previous works, Gao et al. provided a wearable, inexpensive, and possibly scalable biosensing strategy based on mesoporous graphene electrodes made by CO2 laser engraving. , The graphene-based biosensor enabled rapid, accurate, multiplexed, and wireless monitoring of tyrosine (Tyr) as well as uric acid (UA) at low concentrations in human perspiration. The satisfied carrier mobility, significant electron transfer rate, and large surface area endow graphene with outstanding electrochemical properties, particularly appropriate for constructing biosensors to probe electroactive analytes at ultra-low concentrations in body fluids.8, 9, 10 The detection limits of the biosensors to UA and Tyr were down to 0.74 μM and 3.6 μM, respectively. It is believed that the laser-engraved graphene-based biosensing device with high sensitivity, low-cost, and rapid detection ability to probe biomarkers from human biofluids will promote its potential clinical application. With these solid foundations, Gao et al. recently demonstrated a wireless multiplexed electrochemical device to monitor COVID-19 with the features of low in price, high sensitivity, and rapidity, as named SARS-CoV-2 RapidPlex (Figure 1 ). The device could detect not only the viral antigen, immunoglobulins, but also the inflammatory biomarker, which represents three main COVID-19 aspects including the infection of virus, immunoreaction, and severity of clinical symptoms. This device contained four working electrodes and one counter electrode that were made of graphene, together with one Ag/AgCl reference electrode. All the electrodes were patterned by laser engraving on a polymeric substrate, which enabled its mass, low-cost production for wide application in the community. Instead of direct functionalization on graphene that generally requires a defected surface structure, 1-pyrenebutyric acid (PBA) was conjugated on the graphene sheet surface via π-π stacking and hydrophobic interaction, which was further utilized for binding the capturing receptors on the working electrodes. Immobilization of specific receptors including nucleocapsid protein (NP), immunoglobulins against spike protein of the virus (S1-IgG, S1-IgM), and C-reactive protein (CRP) relied on covalently bonding their amino groups with carboxylic groups in PBA. In this way, the graphene maintained its initial structure and functionalities, ensuring good stability of the sensing layer. Besides, the presence of PBA together with an optimal blocking process by bovine serum albumin (BSA) also contributed to preventing non-specific adsorptions of large biomolecules on the graphene surface. The detection of each target biomolecules was visualized through comparing the amperometric signals in the absence and after binding of target analytes on each graphene working electrode, and the data could be wirelessly transmitted to a remote device over Bluetooth.
Figure 1

Sensitive, Rapid, Low-Cost and Multiplexed COVID-19 Monitoring by the Wireless Telemedicine Platform

Sensitive, Rapid, Low-Cost and Multiplexed COVID-19 Monitoring by the Wireless Telemedicine Platform Aiming for an urgently needed fast-detection platform for COVID-19, the target binding time greatly determines its implementation potential. By comparing the amperometric signals from each sensing unit after incubating with blank and target samples (low to 500 pg/mL), a significant change was quickly observed within 1 min of incubation. Notably, to ensure reliable sensitivity for detecting each target molecule at an ultra-low concentration, the incubation was recommended to perform for 10 min. Unlike other determination approaches based on either ELISA test, nucleic acid amplification, or mass spectrometry that is mostly hindered by complex sample preparation, high-cost, or bulky systems, the short-to-answer time endowed the as-developed device more implementation potential as a point-of-care (POC) system. Relative standard deviation (RSD) analysis on the response of different batch biosensors presented good reproducibility in terms of the fabrication process and signal transduction. Even after 5-days storage at 4°C, the detection performance showed negligible fluctuation. In the selectivity evaluation of the SARS-CoV-2 RapidPlex platform, no significant cross-reaction between the SARS-CoV-2 biomarker and that of interferents (non-target molecules) such as SARS and MERS coronaviruses was realized. More importantly, Gao et al. verified that there’s no mutual interference between the readout from neighboring working electrodes when buffered solutions containing all the targets were applied, i.e., 1 ng/mL of NP antigen, 250 ng/mL of S1 specific IgG and IgM, and 50 ng/mL of CRP. To evaluate the clinical potential of this multiplexed platform, Gao et al. performed detections on both COVID-19-positive and COVID-19-negative blood/saliva samples from healthy individuals and confirmed patients. The device was able to simultaneously provide a positive readout for each individual target molecule after 1 min incubation with the COVID-19 positive serum samples. The signal-to-blank ratios representing the signal changes were 10.53 for NP, 11.62 for S1-IgG, 10.67 for S1-IgM, and 12.39 for CRP in serum samples, respectively, while the corresponding values were 2.81, 3.24, 1.62, and 1.76 in saliva samples. In the test on patient biospecimens, concentrations of the four biomarkers detected by the device were in the range of submicro- to micro-gram per milliliter in serum samples, and a range down to nanogram per milliliter in saliva samples. The positive readings of the biomarkers in patients’ saliva supported the non-invasive diagnosis approach of SARS-CoV-2 infection from this biofluid. Moreover, through CRP concentration evaluation, various COVID-19 symptom severity grades could be determined, which would benefit the efficient allocation of medical attention and precious resources. Overall, this study presents a novel wireless electrochemical platform of SARS-CoV-2 RapidPlex, aiming to accurately, rapidly, and inexpensively detect COVID-19 through the simultaneously multiplex test of NP antigen, S1-specific IgG and IgM, and CRP in serum/saliva. Further studies concerning large-scale clinical tests are still needed to verify the reliability of the biosensors before its real implementation as an efficient POC system contributing to fighting this COVID-19 pandemic. Further technological improvement may rely on the integration of an automated microfluidic module for handling samples, and probably wearable biosensors for continuously monitoring an individual’s health status against the COVID-19 infection.
  8 in total

Review 1.  Biological and chemical sensors based on graphene materials.

Authors:  Yuxin Liu; Xiaochen Dong; Peng Chen
Journal:  Chem Soc Rev       Date:  2011-12-05       Impact factor: 54.564

Review 2.  Emerging two-dimensional monoelemental materials (Xenes) for biomedical applications.

Authors:  Wei Tao; Na Kong; Xiaoyuan Ji; Yupeng Zhang; Amit Sharma; Jiang Ouyang; Baowen Qi; Junqing Wang; Ni Xie; Chulhun Kang; Han Zhang; Omid C Farokhzad; Jong Seung Kim
Journal:  Chem Soc Rev       Date:  2019-06-04       Impact factor: 54.564

3.  A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat.

Authors:  Yiran Yang; Yu Song; Xiangjie Bo; Jihong Min; On Shun Pak; Lailai Zhu; Minqiang Wang; Jiaobing Tu; Adam Kogan; Haixia Zhang; Tzung K Hsiai; Zhaoping Li; Wei Gao
Journal:  Nat Biotechnol       Date:  2019-11-25       Impact factor: 54.908

4.  Responding to Covid-19 - A Once-in-a-Century Pandemic?

Authors:  Bill Gates
Journal:  N Engl J Med       Date:  2020-02-28       Impact factor: 91.245

5.  Investigation of cortisol dynamics in human sweat using a graphene-based wireless mHealth system.

Authors:  Rebeca M Torrente-Rodríguez; Jiaobing Tu; Yiran Yang; Jihong Min; Minqiang Wang; Yu Song; You Yu; Changhao Xu; Cui Ye; Waguih William IsHak; Wei Gao
Journal:  Matter       Date:  2020-02-26

6.  Development and clinical application of a rapid IgM-IgG combined antibody test for SARS-CoV-2 infection diagnosis.

Authors:  Zhengtu Li; Yongxiang Yi; Xiaomei Luo; Nian Xiong; Yang Liu; Shaoqiang Li; Ruilin Sun; Yanqun Wang; Bicheng Hu; Wei Chen; Yongchen Zhang; Jing Wang; Baofu Huang; Ye Lin; Jiasheng Yang; Wensheng Cai; Xuefeng Wang; Jing Cheng; Zhiqiang Chen; Kangjun Sun; Weimin Pan; Zhifei Zhan; Liyan Chen; Feng Ye
Journal:  J Med Virol       Date:  2020-04-13       Impact factor: 2.327

7.  Assessment of SARS-CoV-2 Screening Strategies to Permit the Safe Reopening of College Campuses in the United States.

Authors:  A David Paltiel; Amy Zheng; Rochelle P Walensky
Journal:  JAMA Netw Open       Date:  2020-07-01

8.  SARS-CoV-2 RapidPlex: A Graphene-Based Multiplexed Telemedicine Platform for Rapid and Low-Cost COVID-19 Diagnosis and Monitoring.

Authors:  Rebeca M Torrente-Rodríguez; Heather Lukas; Jiaobing Tu; Jihong Min; Yiran Yang; Changhao Xu; Harry B Rossiter; Wei Gao
Journal:  Matter       Date:  2020-10-05
  8 in total
  9 in total

Review 1.  Chitosan Nanoparticles for Antiviral Drug Delivery: A Novel Route for COVID-19 Treatment.

Authors:  Abdel-Majed Safer; Stefano Leporatti
Journal:  Int J Nanomedicine       Date:  2021-12-16

2.  2D MXenes with antiviral and immunomodulatory properties: A pilot study against SARS-CoV-2.

Authors:  Mehmet Altay Unal; Fatma Bayrakdar; Laura Fusco; Omur Besbinar; Christopher E Shuck; Süleyman Yalcin; Mine Turktas Erken; Aykut Ozkul; Cansu Gurcan; Oguzhan Panatli; Gokce Yagmur Summak; Cemile Gokce; Marco Orecchioni; Arianna Gazzi; Flavia Vitale; Julia Somers; Emek Demir; Serap Suzuk Yildiz; Hasan Nazir; Jean-Charles Grivel; Davide Bedognetti; Andrea Crisanti; Kamil Can Akcali; Yury Gogotsi; Lucia Gemma Delogu; Açelya Yilmazer
Journal:  Nano Today       Date:  2021-03-18       Impact factor: 18.962

Review 3.  Molecular detection of SARS-CoV-2 being challenged by virus variation and asymptomatic infection.

Authors:  Congshan Jiang; Xiaowei Li; Changrong Ge; Yuanyuan Ding; Tao Zhang; Shuai Cao; Liesu Meng; Shemin Lu
Journal:  J Pharm Anal       Date:  2021-03-26

4.  Graphene-Based Technologies for Tackling COVID-19 and Future Pandemics.

Authors:  Shaila Afroj; Liam Britnell; Tahmid Hasan; Daria V Andreeva; Kostya S Novoselov; Nazmul Karim
Journal:  Adv Funct Mater       Date:  2021-09-16       Impact factor: 19.924

5.  High-sensitivity and point-of-care detection of SARS-CoV-2 from nasal and throat swabs by magnetic SERS biosensor.

Authors:  Yanyan Li; Chenglong Lin; Yusi Peng; Jun He; Yong Yang
Journal:  Sens Actuators B Chem       Date:  2022-04-28       Impact factor: 9.221

Review 6.  Fluorescent Biosensors for the Detection of Viruses Using Graphene and Two-Dimensional Carbon Nanomaterials.

Authors:  Ahmed M Salama; Ghulam Yasin; Mohammed Zourob; Jun Lu
Journal:  Biosensors (Basel)       Date:  2022-06-27

7.  CRISPR-Cas12a-Empowered Electrochemical Biosensor for Rapid and Ultrasensitive Detection of SARS-CoV-2 Delta Variant.

Authors:  Chenshuo Wu; Zhi Chen; Chaozhou Li; Yabin Hao; Yuxuan Tang; Yuxuan Yuan; Luxiao Chai; Taojian Fan; Jiangtian Yu; Xiaopeng Ma; Omar A Al-Hartomy; S Wageh; Abdullah G Al-Sehemi; Zhiguang Luo; Yaqing He; Jingfeng Li; Zhongjian Xie; Han Zhang
Journal:  Nanomicro Lett       Date:  2022-08-04

Review 8.  Nanotechnology for the management of COVID-19 during the pandemic and in the post-pandemic era.

Authors:  Chun Xu; Chang Lei; Sepanta Hosseinpour; Saso Ivanovski; Laurence J Walsh; Ali Khademhosseini
Journal:  Natl Sci Rev       Date:  2022-06-27       Impact factor: 23.178

9.  Identifying infectiousness of SARS-CoV-2 by ultra-sensitive SnS2 SERS biosensors with capillary effect.

Authors:  Yusi Peng; Chenglong Lin; Yanyan Li; Yong Gao; Jing Wang; Jun He; Zhengren Huang; Jianjun Liu; Xiaoying Luo; Yong Yang
Journal:  Matter       Date:  2021-12-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.